HP Insight Management WBEM Providers for HP integrated VMware ESXi 5.1 U2 June 2014 Datasheets

Table 16-72 HP_DeviceIndication: SAS HBA status OK
Property name
Property implementation
SystemGUID Platform GUID of the computer system generating the
indication
ImpactedDomain
3 (Enclosure) for c-Class blade systems
4 (System) for all other systems
When ImpactedDomain is 3 (Enclosure), the properties
indicated with (*) are populated.
BladeBay *
HP_BladeCSLocation.LocationInformation[0]
BladeName *
HP_ComputerSystem.Name
EnclosureName *
HP_BladeEnclosureCS.Name
RackName *
Rack name if one exists
RackUID *
Rack Unique Identifier if one exists
SystemVirtualSerialNumber Conditional property containing the virtual system
serial number string when running in a Virtual Connect
environment
SystemVirtualUUID Conditional property containing the virtual system
UUID when running in a Virtual Connect environment
SolutionProductModel Conditional property containing the Solution Name
string when running in a aggregate product
environment in the format <aggregate product family
name> v<major>.<minor>.<update>
HP_HardwareIndication
HWFirmwareVersion
Controller firmware version string
HWLogicalLocation Controller Location string
For example, Slot 3
HWManufacturer
Controller Manufacturer string
HWSerialNumber
Controller Serial Number
HP_DeviceIndication
DeviceModel
Controller Model string
1-2-2 SAS HBA in Error state
Table 16-73 HP_DeviceIndication: SAS HBA in Error state
Property name
Property implementation
CIM_Indication
IndicationIdentifier
GUID string generated at the time of indication
PerceivedSeverity Severity
5 (Major)