HP Insight Management WBEM Providers for HP integrated VMware ESXi 5.1 U2 June 2014 Datasheets

Table 16-75 HP_DeviceIndication: Physical Drive status ERROR
Property name
Property implementation
SystemProductID Product ID of the computer system generating the
indication
SystemModel Model name of the computer system generating the
indication
SystemGUID Platform GUID of the computer system generating the
indication
VariableNames
FailureDescription
VariableTypes
1 (String)
VariableValues Short Description of failure
In some cases, the property VariableValues can have
N/A or “” values.
ImpactedDomain
3 (Enclosure) for c-Class blade systems
4 (System) for all other systems
When ImpactedDomain is 3 (Enclosure), the properties
indicated with (*) are populated.
BladeBay *
HP_BladeCSLocation.LocationInformation[0]
BladeName *
HP_ComputerSystem.Name
EnclosureName *
HP_BladeEnclosureCS.Name
RackName *
Rack name if one exists
RackUID *
Rack Unique Identifier if one exists
SystemVirtualSerialNumber Conditional property containing the virtual system
serial number string when running in a Virtual Connect
environment
SystemVirtualUUID Conditional property containing the virtual system
UUID when running in a Virtual Connect environment
SolutionProductModel Conditional property containing the Solution Name
string when running in a aggregate product
environment in the format <aggregate product family
name> v<major>.<minor>.<update>
HP_HardwareIndication
HWFirmwareVersion
Disk firmware version string
HWLogicalLocation Disk Location string
For example, Bay 3
HWManufacturer
Disk Manufacturer string
HWSerialNumber
Disk Serial Number
HP_DeviceIndication
DeviceModel
Disk Model string