HP Insight Management WBEM Providers for HP integrated VMware ESXi 5.1 U2 June 2014 Datasheets

Table 16-78 HP_DeviceIndication: Drive status PREDICTIVE FAILURE due to SSD Wear out
Property name
Property implementation
RackUID *
Rack Unique Identifier if one exists
SystemVirtualSerialNumber Conditional property containing the virtual system
serial number string when running in a Virtual Connect
environment
SystemVirtualUUID Conditional property containing the virtual system
UUID when running in a Virtual Connect environment
SolutionProductModel Conditional property containing the Solution Name
string when running in a aggregate product
environment in the format <aggregate product family
name> v<major>.<minor>.<update>
HP_HardwareIndication
HWFirmwareVersion
Disk firmware version string
HWLogicalLocation Disk Location string
For example, Bay 3
HWManufacturer
Disk Manufacturer string
HWSerialNumber
Disk Serial Number
HP_DeviceIndication
DeviceModel
Disk Model string
1-2-8 Physical Drive status ERROR due to authentication
failure
Table 16-79 HP_DeviceIndication: Drive status changed to Error due to authentication failure
Property name
Property implementation
CIM_Indication
IndicationIdentifier
GUID string generated at the time of indication
PerceivedSeverity
3 (Warning)
IndicationTime
Time of indication
CIM_AlertIndication
Description A physical drive status has changed to Error due to
authentication failure
AlertingManagedElement
WBEM Path of disk drive
AlertingElementFormat
2 (CIMObjectPath)
AlertType
5 (Device Alert)
EventID
402