HP Insight Management WBEM Providers for HP integrated VMware ESXi 5.1 U2 June 2014 Datasheets

1-2-12 Enclosure Power Supply status changed to Non
Redundant
Table 16-83
HP_DeviceIndication: Enclosure Power Supply status changed to Non Redundant
Property name
Property implementation
CIM_Indication
IndicationIdentifier
GUID string generated at the time of indication
PerceivedSeverity
3 (Warning)
IndicationTime
Time of indication
CIM_AlertIndication
Description A Storage Enclosure Power Subsystem status has
changed to non-redundant.
AlertingManagedElement
WBEM Path of HP_StorageEnclosureProcessor
AlertingElementFormat
2 (CIMObjectPath)
AlertType
5 (Device Alert)
EventID
301
EventTime Time of the event or time of the indication if event time
unknown
ProviderName
HP SAS
RecommendedActions Check status of all enclosure power supplies. Ensure
that power supplies have not failed. Add or replace
power supplies as necessary.
SystemName
Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating
the indication
HP_AlertIndication
Summary
Power Supply status Non-Redundant
EventCategory
17 (Primary Storage Power)
ProbableCause
89 (Power Supply Failure)
ProbableCauseDescription Redundant Power Supply Status Changed to Non-
Redundant
ProviderVersion Provider version generating the indication in the
format, <major>.<minor>.<revision>.<build>
NetworkAddresses List of all the IP addresses of the computer system
generating the indication
OSType
On ESXi, 39(VM)