HP Insight Management WBEM Providers for HP integrated VMware ESXi 5.1 U2 June 2014 Datasheets

Property Name
Property Implementation
CurrentReading
Current reading of temperature sensor
BaseUnits
2 (Degrees C)
RateUnits
0
(None)
UnitModifier
0
SupportedThresholds
SupportedThresholds[0] = 1 (UpperThresholdNotCritical) if
the system will set fans to full speed if the threshold is crossed;
SupportedThresholds[0] = 3 (UpperThresholdCritical) set if
the system will gracefully attempt to shutdown the system if the
threshold is crossed;
SupportedThresholds[0] = 5 (UpperThresholdFatal) if the
system will immediately power down the system if the threshold is
crossed.
UpperThresholdNonCritical
Contains the threshold temperature that CurrentReading must exceed
to be in a non-critical state. This is only set if the system will set fans to
full speed if the threshold is crossed.
UpperThresholdCritical
Contains the threshold temperature that CurrentReading must exceed
to be in a critical state. This is only set if the system will gracefully
attempt to shutdown the system if the threshold is crossed.
UpperThresholdFatal
Contains the threshold temperature that
CurrentReading
must exceed
to be fatal. This is only set if the system will immediately power down the
system if the threshold is crossed.
HP_NumericSensor
NumericSensorType
Enumeration describing the type of temperature sensor. Refer to the
Managed Object Format.
HP Insight Management WBEM System Temperature Sensor Provider 5