HP Insight Management WBEM Providers for HP integrated VMware ESXi 5.1 U2 June 2014 Datasheets

Property Name
Property Implementation
CIM_ManagedSystemElement
Name
Serial number
HealthState 0 (Unknown)
5 (OK)
10 (Degraded/Warning)
15 (Minor Failure)
20 (Major Failure)
25 (Critical Failure)
30 (Non-recoverable Error)
CIM_LogicalElement
Caption Disk Y on HPSA X
CIM_EnabledLogicalElement
CIM_LogicalDevice
CreationClassName
HPVC_SAStorageExtent
DeviceID HPVC_SAStorageExtent-<model>-<serial number>
e.g. HPVC_SAStorageExtent-HPDG072BB975-
3NP2TCCF000098402P95
SystemCreationClassName SMX_ComputerSystem
SystemName Server host name
CIM_StorageExtent
BlockSize Block size in bytes
NumberOfBlocks Total number of blocks on disk drive
Primordial Set to “True”
VMware_StorageExtent
HPVC_SAStorageExtent
2.5 HPVC_SAStorageVolume
HPVC_SAStorageVolume reprents logical volumes configured on Smart Array controller. There will be
one instance per logical volume.
Table 5 – Class: HPVC_SAStorageVolume
Property Name Property Implementation
CIM_ManagedElement