HP Insight Management WBEM Providers for HP integrated VMware ESXi 5.1 U2 June 2014 Datasheets

Property Name
Property Implementation
SolutionProductModel
Conditional property containing the Solution Name string when running
in a aggregate product environment in the format <aggregate product
family name> v<major>.<minor>.<update>
HP_HardwareIndication
HWLogicalLocation
Enclosure Location string
For example:
Port 1I Box 1
HWSerialNumber
Enclosure Serial Number
HP_DeviceIndication
DeviceModel
Enclosure Model string
1-3-46 HP_DeviceIndication: Enclosure Fan Status Changed to
OK
Property Name
Property Implementation
CIM_Indication
IndicationIdentifier
Unique identifying string generated at the time of indication
PerceivedSeverity
2 (Info)
IndicationTime
Time of indication
CIM_AlertIndication
Description
A Storage Enclosure Fan status has changed from a non-
OK state to OK.
AlertingManagedElement
WBEM Path of SMX_SAStorageEnclosureProcessor
AlertingElementFormat
2 (CIMObjectPath)
HP Insight Management WBEM Smart Array Provider 243