HP Insight Management WBEM Providers for HP integrated VMware ESXi 5.1 U2 June 2014 Datasheets

Property Name
Property Implementation
HP_DeviceIndication
DeviceModel
Enclosure Model string
1-3-48 HP_DeviceIndication: Enclosure Fan Status change to
Failure
Property Name
Property Implementation
CIM_Indication
IndicationIdentifier
Unique identifying string generated at the time of indication
PerceivedSeverity
5
(major)
IndicationTime
Time of indication
CIM_AlertIndication
Description
A Storage Enclosure Fan status changed to Failure. An
enclosure has detected a failure in the fan subsystem
and there is insufficient fan capability to ensure
normal operation.
AlertingManagedElement
WBEM Path of
SMX_SAStorageEnclosureProcessor
AlertingElementFormat
2
(CIMObjectPath)
AlertType
5
(Device Alert)
EventID
306
EventTime
Time of the event or time of the indication if event time unknown
ProviderName
HP Smart Array
RecommendedActions
Ensure that the system is adequately ventilated. Check
for proper room temperature and internal/external
airflow. Add or repair fans and air baffling if
HP Insight Management WBEM Smart Array Provider 249