HP Insight Management WBEM Providers for HP integrated VMware ESXi 5.1 U2 June 2014 Datasheets

Property Name
Property Implementation
CIM_ManagedSystemElement
OperationalStatus
0 (Unknown)
2 (OK), when CPU is enabled and operational
5 (Predictive Failure), when IML error info logged for this CPU
6 (Error), when CPU is disabled via POST error
10 (Stopped), when CPU is disabled via RBSU
StatusDescriptions
StatusDescriptions[0] text per OperationalStatus[0]:
Unknown
OK
Stopped
Error
Predictive Failure
HealthState
0 (Unknown), when OperationalStatus[0]=0 (Unknown)
5 (OK), when OperationalStatus[0]=2 (OK)
15 (Minor Failure), when OperationalStatus[0]=10 (Stopped)
20 (Major Failure), when OperationalStatus[0]=5 (Predictive Failure)
25 (Critical Failure), when OperationalStatus[0]=6 (Error)
CIM_LogicalElement
CIM_EnabledLogicalElement
EnabledState
5 (Not Applicable)
RequestedState
12 (Not Applicable)
HP Insight Management WBEM CPU Provider Overview 15