HP Insight Management WBEM Providers for HP integrated VMware ESXi 5.5 and 5.5 U1 June 2014 Datasheets

SendTestIndication
Method Parameters:
EventID, number of test event to send:
101 - Send Information Test Indication
102 - Send Warning Test Indication
103 - Send Critical Test Indication
Return Values:
0 - request to send indication successful
1 - method unsupported
2 - request to send indication failed
3 - provider is busy processing previously requested indication, try again
4 - EventID is not one of the defined values
Exception: CIM_ERR_INVALID_PARAMETER - EventID is the wrong type,
does not exist or other internal error.
1-2-2 SMX_ComputerSystemChassis Class
The SMX_ComputerSystemChassis class implements the HP_ComputerSystemChassis class to model
the physical system chassis. There is only one instance of
SMX_ComputerSystemChassis instantiated on a
server.
The following table lists the properties implemented.
Property Name
Property Implementation
CIM_PhysicalElement
Tag
Unique value for instance.
For example:
1
CreationClassName
SMX_ComputerSystemChassis
ElementName
Computer system product name (model) string.
HP Insight Manager WBEM Base Server Provider Overview 10