HP Insight Management WBEM Providers for HP integrated VMware ESXi 5.5 and 5.5 U1 June 2014 Datasheets

Property Name
Property Implementation
For example:
Power Supply1 at PowerSupplySlot=2, Power Supply 1a at
PowerSupplySlot=2
CIM_ManagedSystemElement
OperationalStatus[0]
2 (OK) if power supply is operating properly;
3 (Degraded) if power supply is degraded;
6 (Error) if power supply has failed
OperationalStatus[1]
Extended Warning and Error status. See the MOF and Profile
StatusDescriptions[0]
Description of the status of the power supply corresponding to the
OperationalStatus.
For example:
Power Supply is operating properlyif OperationalStatus[0]
is 2 (OK);
Power Supply is degradedif OperationalStatus[0] is 3
(Degraded)
Power Supply has failedif OperationalStatus is 6 (Error)
StatusDescriptions[1]
Description of the extended warning/error status corresponding to the
OperationalStatus[1]. See Profile.
HealthState
5 (OK) if power supply is operating properly;
10 (Degraded) if power supply is degraded
20 (Major Failure) if power supply has failed
Name
Unique name of this power supply from the name displayed by the MP or
iLO and its location.
For example:
Power Supply1 at PowerSupplySlot=2, Power Supply 1a at
PowerSupplySlot=2
HP Insight Management Power Supply Provider Overview 4