HP Insight Management WBEM Providers for HP integrated VMware ESXi 5.5 and 5.5 U1 June 2014 Datasheets

Property Name
Property Implementation
RecommendedActions
“Check the input power being supplies to the failed power supply and
reconnect power.”
HP_AlertIndication
Summary
“Power supply failed input power lost“
EventCategory
16 (System Power)
ProbableCause
89 (Power Supply Failure)
ProbableCauseDescription
“Power Supply Failed due to input power loss.”
1-3-3 HP_DeviceIndication: Power Supply Removed
Property Name
Property Implementation
CIM_Indication
PerceivedSeverity
2 (Information)
CIM_AlertIndication
Description
A power supply has been removed.
PowerSupply
Where: PowerSupply is the system power supply that was removed.
AlertingManagedElement
WBEM Path of the SMX_PowerSupply instance.
AlertingElementFormat
2 (CIMObjectPath)
AlertType
5 (Device Alert)
EventID
1
ProviderName
HP Power
RecommendedActions
Check the system power supply configuration. Verify that this power
HP Insight Management Power Supply Provider Overview 26