HP Insight Management WBEM Providers for HP integrated VMware ESXi 5.5 and 5.5 U1 June 2014 Datasheets

Table 16-83 HP_DeviceIndication: Enclosure Power Supply status changed to Non Redundant
Property name
Property implementation
HP_DeviceIndication
DeviceModel
Enclosure Model string
1-2-13 Enclosure Power Supply Status changed to OK
(Redundant)
Table 16-84 HP_DeviceIndication: Enclosure Power Supply status changed to OK (Redundant)
Property name
Property implementation
CIM_Indication
IndicationIdentifier
GUID string generated at the time of indication
PerceivedSeverity
2 (Info)
IndicationTime
Time of indication
CIM_AlertIndication
Description A Storage Enclosure Power Supply has changed to
Fully Redundant.
AlertingManagedElement
WBEM Path of SMX_SASStorageEnclosureProcessor
AlertingElementFormat
2 (CIMObjectPath)
AlertType
5 (Device Alert)
EventID
302
EventTime Time of the event or time of the indication if event time
unknown
ProviderName
HP SAS
RecommendedActions
No action is recommended.
SystemName
Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating
the indication
HP_AlertIndication
Summary
Redundant power supply status OK
EventCategory
17 (Primary Storage Power)
ProbableCause
1 (Other)
ProbableCauseDescription
Redundant Power Supply Status Changed to OK
ProviderVersion Provider version generating the indication in the
format, <major>.<minor>.<revision>.<build>
NetworkAddresses Contains a list of all the IP addresses (IPv4 and IPv6) of
the computer system generating the indication