HP Insight Management WBEM Providers for HP integrated VMware ESXi 5.5 and 5.5 U1 June 2014 Datasheets

Table 16-87 HP_DeviceIndication: Enclosure Temperature sensor status changed to Warning
Property name
Property implementation
ImpactedDomain
3 (Enclosure) for c-Class blade systems
4 (System) for all other systems
When ImpactedDomain is 3 (Enclosure), the properties
indicated with (*) are populated.
BladeBay *
HP_BladeCSLocation.LocationInformation[0]
BladeName *
HP_ComputerSystem.Name
EnclosureName *
HP_BladeEnclosureCS.Name
RackName *
Rack name if one exists
RackUID *
Rack Unique Identifier if one exists
SystemVirtualSerialNumber Conditional property containing the virtual system
serial number string when running in a Virtual Connect
environment
SystemVirtualUUID Conditional property containing the virtual system
UUID when running in a Virtual Connect environment
SolutionProductModel Conditional property containing the Solution Name
string when running in a aggregate product
environment in the format <aggregate product family
name> v<major>.<minor>.<update>
HP_HardwareIndication
HWLogicalLocation Enclosure Location string
For example, Port 1I Box 1
HWSerialNumber
Enclosure Serial Number
HP_DeviceIndication
DeviceModel
Enclosure Model string
1-2-17 Enclosure Temperature sensor Status Changed to
Critical
Table 16-88 HP_DeviceIndication: Enclosure Temperature sensor status changed to Critical
Property name
Property implementation
CIM_Indication
IndicationIdentifier
GUID string generated at the time of indication
PerceivedSeverity
5 (major)
IndicationTime
Time of indication
CIM_AlertIndication