HP Insight Management WBEM Providers for HP integrated VMware ESXi 5.5 and 5.5 U1 June 2014 Datasheets

Property Name
Property Implementation
PerceivedSeverity
3 (Warning)
IndicationTime
Time of indication
CIM_AlertIndication
Description
The physical drive was not able to be
authenticated and could not be validated to be a
genuine HP hard drive. The array controller will
no longer control the drive LEDs.
AlertingManagedElement
WBEM Path of SMX_SADiskDrive class
AlertingElementFormat
2 (CIMObjectPath)
AlertType
5 (Device Alert)
EventID
207
EventTime
Time of the event or time of the indication if event time
unknown
ProviderName
HP Smart Array (
RecommendedActions
Please replace the hard drive with a genuine HP
hard drive
SystemName
Name of the computer system generating the indication
SystemCreationClassName
CreationClassName of the computer system generating the
indication
HP_AlertIndication
Summary
Physical drive status warning
EventCategory
6 (Primary Storage)
ProbableCause
86 (Disk Failure)
HP Insight Management WBEM Smart Array Provider 110