HP Insight Management WBEM Providers for HP integrated VMware ESXi 5.5 and 5.5 U1 June 2014 Datasheets

1-3-23 SMX_SAStorageVolumeIndication: Logical Drive Status
Changed to Rapid Parity Initialization in progress
Property Name
Property Implementation
CIM_Indication
IndicationIdentifier
GUID string generated at the time of indication
PerceivedSeverity
3
Warning
IndicationTime
Time of indication
CIM_AlertIndication
Description
A logical drive status has changed to Rapid
Parity Initialization in progress.
AlertingManagedElement
WBEM Path of
SMX_SAStorageVolume
class
AlertingElementFormat
2
(CIMObjectPath)
AlertType
5
(Device Alert)
EventID
111
EventTime
Time of the event or time of the indication if event time
unknown
ProviderName
HP Smart Array
RecommendedActions
Check status of Logical drives. Degraded status
may be caused by Rapid Parity Initialazation is
in progress.
SystemName
Name of the computer system generating the indication
SystemCreationClassName
CreationClassName
of the computer system generating the
indication
HP_AlertIndication
HP Insight Management WBEM Smart Array Provider 168