HP Insight Management WBEM Providers for HP integrated VMware ESXi 5.5 and 5.5 U1 June 2014 Datasheets

Property Name
Property Implementation
ProbableCauseDescription
Fan inserted
1-3-4 HP_DeviceIndication: Fan Failed
Property Name
Property Implementation
CIM_Indication
PerceivedSeverity
5 (Major)
CIM_AlertIndication
Description
A fan has failed. <
FanCaptio>
Where: <FanCaption> is the SMX_Fan.Caption for the fan that has
failed.
AlertingManagedElement
WBEM Path of SMX_Fan instance representing the failed fan.
AlertingElementFormat
2 (CIMObjectPath)
AlertType
5 (Device Alert)
EventID
3
ProviderName
HP Cooling
RecommendedActions
Please Check the failed fan and replace if necessary.
HP_AlertIndication
Summary
Fan failed
EventCategory
23 (System Cooling)
ProbableCause
94 (Fan Failure)
ProbableCauseDescription
Fan Failed