HP Insight Management WBEM Providers for HP integrated VMware ESXi 5.5 and 5.5 U1 June 2014 Datasheets

1-2-4 SMX_MemoryBoard Class
The SMX_MemoryBoard class represents a physical memory board on HP servers. There is an instance of
this class for each memory module present in the system; empty memory module sockets are not
instantiated.
The following table lists the properties implemented.
Property Name
Property Implementation
CIM_ManagedElement
Caption
Physical Memory <physical location>.
Refer to “Physical Location” for more information.
CIM_ManagedSystemElement
OperationalStatus
Enumerator indicating the memory board operational status.
OperationalStatus[0] contains overall memory board status
OperationalStatus[1] contains detailed memory board status (as
needed)
For details, see “Properties for Memory Board Status”.
StatusDescriptions
StatusDescriptions[0]
contains descriptive text per
OperationalStatus[0]:
StatusDescriptions[1]contains descriptive text per
OperationalStatus[1]:
For details, see “Properties for Memory Board Status”.
HealthState
Enumerator indicating the memory board health state:
0 (Unknown), when OperationalStatus[0]= 0 (Unknown)
5 (OK), when OperationalStatus[0] = 2 (OK)
10 (Degraded/Warning), when OperationalStatus[0] = 3 (Degraded)
Name
Physical Memory <physical location>.
Refer to “Physical Location” for more information.
HP Insight Management WBEM System Memory Provider 11