HP Insight Management WBEM Providers for HP integrated VMware ESXi Data Sheet Part number 616894-003 Third Edition September 2011
© Copyright 2009, 2011 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP will not be liable for technical or editorial errors or omissions contained herein. Confidential computer software.
Table of Contents HP Insight Manager WBEM Base Server Provider Overview............................................................12 Setting Up the Provider...........................................................................................................................................................12 Using the Provider ..................................................................................................................................................................
SMX_CacheMemory Class ..............................................................................................................................................69 SMX_SystemProcessor Class...........................................................................................................................................71 SMX_ProcessorElementCapabilities Class ......................................................................................................................
HP_AlertIndication: Ethernet Team Member Added .....................................................................................................117 HP_AlertIndication: Network Interface No Longer Available .......................................................................................118 HP_AlertIndication: Network Interface Available .........................................................................................................
SMX_MPConsolidatedStatusView Class .......................................................................................................................158 SMX_MPScopedConsolidatedStatusView Class ...........................................................................................................158 SMX_ManagementController Class ...............................................................................................................................159 SMX_MPControllerMP Class ...............
SMX_RegisteredProfile Class ........................................................................................................................................200 SMX_ExtendsProfile Class ............................................................................................................................................202 SMX_ReferencedProfile Class .......................................................................................................................................
SMX_SASPrimordialPoolNoRaidStorageExtent (Association)....................................................................................229 SMX_SASStorageSpecificCollectionArraySystem (Association) ...............................................................................229 SMX_SASStorageRedundancySetStorageExtent (Association) ...................................................................................229 SMX_SASArraySystemFirmware (Association) ..............................................
SMX_SASArraySystemLocation .....................................................................................................278 SMX_SASDiskDriveLocation .........................................................................................................278 SMX_SASStorageCapabilities .........................................................................................................279 SMX_SASProduct................................................................................................
Physical Drive status PREDICTIVE FAILURE.............................................................................................................301 Logical Drive status OK ................................................................................................................................................303 Logical Drive status ERROR .........................................................................................................................................
SMX_SAStorageSpecificCollection Class .....................................................................................................................369 SMX_SADriveCageLocation Class................................................................................................................................370 SMX_SAArraySystemLocation Class............................................................................................................................370 SMX_SADiskDriveLocation Class ...
SMX_SAArraySystemTSASPort (Association).............................................................................................................390 SMX_SADiskDriveTSASSCSIProtocolEndpoint (Association)....................................................................................390 SMX_SASCSIInitiatorTargetLogicalUnitPath...............................................................................................................391 SMX_SAPortControllerPCIDevice (Association).....................
Using the Provider ................................................................................................................................................................459 SMX_Memory Class ......................................................................................................................................................460 SMX_SystemMemory Class .......................................................................................................................................
HP Insight Manager WBEM Base Server Provider Overview The HP Insight Management Web-Based Enterprise Management (WBEM) Base Server provider implements and extends CIM classes described in this document to model the base server. These classes provide computational Description information and capabilities and serve as an aggregation point to associate one or more elements that make up a base server, such as: Fans, PowerSupplies, Processor and Memory (Volatile and/or NonVolatile Storage).
SMX_SystemFirmware SMX_SystemInstalledFirmwareIdentity SMX_SystemElementFirmwareIdentity The tables in the following sections describe the properties of the supported classes. The classes are categorized by the class or superclass that defines the property, the first column is the Property Name (including type and units) and the second column describes how the provider determines the properties implementation.
The following table lists the properties implemented. Property Name Property Implementation CIM_ManagedElement Caption Computer system DNS name returned by uname. Description Computer system DNS name returned by uname. ElementName Computer system DNS name returned by uname. CIM_ManagedSystemElement Status Same as OperationalStatus[0]. contains the computer system consolidated status and indicates the worst status of any connected subsystem.
Property Name StatusDescriptions Property Implementation StatusDescriptions[0] will contain one of the following corresponding to OperationalStatus[0]: One or more of the subsystems that make up this computer system have an OperationalStatus value of Unknown One or more of the subsystems that make up this computer system have an OperationalStatus value of Other One or more of the subsystems that make up this computer system have an OperationalStatus value of Degraded One or more of the subsystems that mak
Property Name Property Implementation OtherIdentifyingInfo[0]: Where: is the computer system string. physical GUID OtherIdentifyingInfo[1]: Where: is the computer system MAC address. OtherIdentifyingInfo[2]: : Where: is the computer system model string; and Serial_Number_String is the computer system physical serial number string.
Property Name Property Implementation PrimaryOwnerName Computer system primary owner name string; initialized to not set. PrimaryOwnerContact Computer system primary owner contact string; initialized to not set. PrimaryOwnerPager Computer system primary owner pager string; initialized to not set. SecondaryOwnerContact Computer system secondary owner contact string; initialized to not set. SecondaryOwnerName Computer system secondary owner name string; initialized to not set.
SMX_ComputerSystemChassis Class The SMX_ComputerSystemChassis class implements the HP_ComputerSystemChassis class to model the physical system chassis. There is only one instance of SMX_ComputerSystemChassis instantiated on a server. The following table lists the properties implemented. Property Name Property Implementation CIM_PhysicalElement Tag Unique value for instance. For example: 1 CreationClassName SMX_ComputerSystemChassis ElementName Computer system product name (model) string.
Property Name Property Implementation HP_ComputerSystemChassis ProductID Computer system product ID string For example: 123456-123. VirtualUUID[] If Synergy is enabled, this will contain the logical UUID for the system. VirtualSerialNumber[] If Synergy is enabled, this will contain the logical Serial Number for the system. TPMModule Indicates the installed and enabled state of the Trusted Platform Module.
Property Name Property Implementation CIM_ManagedSystemElement (OK) OperationalStatus 2 StatusDescriptions StatusDescriptions[0] will to OperationalStatus[0]: contain the value map string corresponding For example: OK Status OK HealthState 5 (OK) PrimaryStatus 1 (OK) CIM_LogicalElement CIM_EnabledLogicalElement EnabledState 2 (Enabled) RequestedState 0 (Unknown) EnabledDefault 2(Enabled) TransitioningToState 12 (Not Applicable) CIM_OperatingSystem CSName SMX_ComputerSystem.
Antecedent References SMX_OperatingSystem Dependent References SMX_ComputerSystem SMX_RunningOS SMX_InstalledOS Class The SMX_InstalledOS class implements the CIM_InstalledOS class and associates the SMX_ComputerSystem instance and a SMX_OperatingSystem instance. The following table lists the properties implemented.
Property Name InstanceID Property Implementation Opaque string using HPQ as OrgID For example: HPQ:SMX_SMXSoftwareIdentity-1. MajorVersion The first numeric value in the VersionString. MinorVersion The second numeric value in the VersionString. RevisionNumber The third numeric value in the VersionString. VersionString Version of SMX, for example: 02.00.00. Manufacturer Hewlett Packard Company Classifications[0] 5 IsEntity TRUE TargetOSTypes[0] On Linux, 36. On ESXi, 39 (VM).
The following table lists the properties implemented. Property Name Property Implementation CIM_ManagedElement A description of the firmware. For example, on HP ProLiant: Caption System ROM Firmware-() () where family_code is the system ROM family code and state is either Active or Redundant. For example: System ROM Firmware-P31 (Active) System ROM Firmware-P31 (Redundant) Description A description of the firmware. ElementName A description of the firmware.
Property Name Property Implementation On HP ProLiant, this will contain: HPQ: Where: IdentityInfoValue For example: is the system ROM family code. HPQ:P31 On HP Integrity, this will contain: HPQ:ElementName IdentityInfoType CIM:SoftwareFamily ReleaseDate YYYYMMDD******.
The following table lists the properties implemented.
Property Name Property Implementation NetworkAddresses Contains a list of all the IP addresses of the computer system generating the indication OSType On ESX, 39 (VM) On Linux, 36 (Linux) OSVersion The operating system version of the computer system generating the indication in the following format: ..
Property Name Property Implementation AlertType 5 (Device Alert) EventID 1 ProviderName HP Test RecommendedActions No action is recommended. HP_AlertIndication Summary Test Event ProbableCause 1 (Other) ProbableCauseDescription Test Indication HP_DeviceIndication: WBEM Providers Warning Test Indication Property Name Property Implementation CIM_Indication PerceivedSeverity 3 (Warning) CIM_AlertIndication Description This is a warning test event.
Property Name RecommendedActions Property Implementation No action is recommended. HP_AlertIndication Summary Test Event ProbableCause 1 (Other) ProbableCauseDescription Test Indication HP_DeviceIndication: ASR Reboot Occurred Property Name Property Implementation CIM_Indication PerceivedSeverity 5 (Major) CIM_AlertIndication Description The system has rebooted from an Automatic Server Recovery (ASR) event.
Property Name Property Implementation not obstructed. HP_AlertIndication Summary Thermal reboot occurred EventCategory 23 (System Cooling) ProbableCause 51 (Temperature Unacceptable) ProbableCauseDescription Thermal reboot occurred HP_DeviceIndication: Fan Failure Reboot Occurred Property Name Property Implementation CIM_Indication PerceivedSeverity 5 (Major) CIM_AlertIndication Description The system has rebooted from fan failure shutdown event.
Property Name RecommendedActions Property Implementation Replace any failed or removed power supplies. HP_AlertIndication Summary VRM failure reboot occurred EventCategory 16 (System Power) ProbableCause 89 (Power Supply Failure) ProbableCauseDescription VRM failure reboot occurred HP_DeviceIndication: POST Occurred Property Name Property Implementation CIM_Indication PerceivedSeverity 5 (Major) CIM_AlertIndication Description Power-On Self-Test errors occurred during the last system startup.
VariableNames[] FailureDescription CacheSizeTotal CacheSerialNumber VariableTypes[] String (1) uint32 (5) FailureDescription – short description of the failure CacheSizeTotal HPSA_ArrayController.CacheSizeTotal VariableValues[] CacheSerialNumber HPSA_ArrayController.
Property Name Property Implementation ProbableCauseDescription Array Controller Cache Status Changed to Temporarily Disabled NetworkAddresses Contains a list of all the IP addresses of the computer system generating the indication OSType SMX_OperatingSystem.OSType OSVersion The operating system version of the computer system generating the indication in the following format: ..
Property Name Property Implementation VariableNames[] FailureDescription CacheSizeTotal CacheSerialNumber VariableTypes[] String (1) uint32 (5) VariableValues[] FailureDescription – short description of the failure CacheSizeTotal HPSA_ArrayController.CacheSizeTotal CacheSerialNumber HPSA_ArrayController.
Property Name Property Implementation (Primary Storage) EventCategory 6 ProbableCause 35 ProbableCauseDescription Array Controller Cache Status Changed to Permanently Disabled NetworkAddresses Contains a list of all the IP addresses of the computer system generating the indication OSType SMX_OperatingSystem.OSType OSVersion The operating system version of the computer system generating the indication in the following format: ..
Property Name Property Implementation HWSerialNumber Array Controller Serial Number VariableNames[] FailureDescription CacheSizeTotal CacheSerialNumber VariableTypes[] String (1) uint32 (5) VariableValues[] FailureDescription – short description of the failure CacheSizeTotal HPSA_ArrayController.CacheSizeTotal CacheSerialNumber HPSA_ArrayController.
Property Name Property Implementation Summary Power Supply status Non-Redundant EventCategory 17 (Primary Storage Power) ProbableCause 89 (Power Supply Failure) ProbableCauseDescription Redundant Power Supply Status Changed to Non-Redundant NetworkAddresses Contains a list of all the IP addresses of the computer system generating the indication OSType SMX_OperatingSystem.
Property Name DeviceModel Property Implementation Enclosure Model string HP_DeviceIndication: Enclosure Power Supply Status changed to OK (Redundant) Property Name Property Implementation CIM_Indication IndicationIdentifier GUID string generated at the time of indication PerceivedSeverity 2 IndicationTime Time of indication (Info) CIM_AlertIndication Description A Storage Enclosure Power Subsystem has changed to Fully Redundant.
Property Name Property Implementation SystemProductID Product ID of the computer system generating the indication SystemModel Model name of the computer system generating the indication SystemGUID Platform GUID of the computer system generating the indication ImpactedDomain (Enclosure) for c-Class blade systems (System) for all other systems Note: When ImpactedDomain is 3 (Enclosure) the properties that follow and are indicated with an asterisk (*) below will be populated.
Property Name Property Implementation AlertingElementFormat 2 (CIMObjectPath) AlertType 5 (Device Alert) EventID 303 EventTime Time of the event or time of the indication if event time unknown ProviderName HP Smart Array RecommendedActions Check status of all enclosure power supplies. Ensure that power supplies have not failed. Add or replace power supplies as necessary.
Property Name Property Implementation RackUID * Rack Unique Identifier, if one exists SystemVirtualSerialNumber Conditional property containing the virtual system serial number string when running in a Virtual Connect environment SystemVirtualUUID Conditional property containing the virtual system UUID when running in a Virtual Connect environment HP_HardwareIndication HWLogicalLocation Enclosure Location string For example: Port 1I Box 1 HWSerialNumber Enclosure Serial Number HP_DeviceIndication
Property Name Property Implementation (Other) ProbableCause 1 ProbableCauseDescription Temperature Status Changed to OK NetworkAddresses Contains a list of all the IP addresses of the computer system generating the indication OSType SMX_OperatingSystem.OSType OSVersion The operating system version of the computer system generating the indication in the following format: ..
HP_DeviceIndication: Enclosure Temperature sensor Status Changed to Warning Property Name Property Implementation CIM_Indication IndicationIdentifier GUID string generated at the time of indication PerceivedSeverity 3 IndicationTime Time of indication (Warning) CIM_AlertIndication Description A Storage Enclosure Temperature sensor status changed to Warning Condition. This indicates the enclosure temperature is above normal, otherwise enclosure is still operating normally.
Property Name Property Implementation SystemProductID Product ID of the computer system generating the indication SystemModel Model name of the computer system generating the indication SystemGUID Platform GUID of the computer system generating the indication ImpactedDomain (Enclosure) for c-Class blade systems (System) for all other systems Note: When ImpactedDomain is 3 (Enclosure) the properties that follow and are indicated with an asterisk (*) below will be populated.
Property Name Property Implementation before loss of data occurs. AlertingManagedElement WBEM Path of SMX_SAStorageEnclosureProcessor AlertingElementFormat 2 (CIMObjectPath) AlertType 5 (Device Alert) EventID 309 EventTime Time of the event or time of the indication if event time unknown ProviderName HP Smart Array RecommendedActions Ensure that the system is adequately ventilated. Check for proper room temperature and internal/external airflow.
Property Name Property Implementation BladeBay * HP_BladeCSLocation.LocationInformation[0] BladeName * HP_ComputerSystem.Name EnclosureName * HP_BladeEnclosureCS.
Property Name Property Implementation HP_AlertIndication Summary Fan status OK EventCategory 24 ProbableCause 1 ProbableCauseDescription Fan Status Changed to OK NetworkAddresses Contains a list of all the IP addresses of the computer system generating the indication OSType SMX_OperatingSystem.OSType OSVersion The operating system version of the computer system generating the indication in the following format: ..
Property Name Property Implementation HP_DeviceIndication DeviceModel Enclosure Model string HP_DeviceIndication: Enclosure Fan Status changed to Degraded Property Name Property Implementation CIM_Indication IndicationIdentifier GUID string generated at the time of indication PerceivedSeverity 3 IndicationTime Time of indication (Warning) CIM_AlertIndication Description A Storage Enclosure Fan status has changed to Degraded.
Property Name Property Implementation ProviderVersion For example: SystemFirmwareVersion Firmware version of the computer system generating the indication SystemSerialNumber Serial number of the computer system generating the indication SystemProductID Product ID of the computer system generating the indication SystemModel Model name of the computer system generating the indication SystemGUID Platform GUID of the computer system generating the indication 2.2.0.
Property Name Property Implementation enclosure has detected a failure in the fan subsystem and there is insufficient fan capability to ensure normal operation. AlertingManagedElement WBEM Path of SMX_SAStorageEnclosureProcessor AlertingElementFormat 2 (CIMObjectPath) AlertType 5 (Device Alert) EventID 306 EventTime Time of the event or time of the indication if event time unknown ProviderName HP Smart Array RecommendedActions Ensure that the system is adequately ventilated.
Property Name Property Implementation ImpactedDomain (Enclosure) for c-Class blade systems (System) for all other systems Note: When ImpactedDomain is 3 (Enclosure) the properties that follow and are indicated with an asterisk (*) below will be populated. BladeBay * HP_BladeCSLocation.LocationInformation[0] BladeName * HP_ComputerSystem.Name EnclosureName * HP_BladeEnclosureCS.
Physical Location The Physical Location is a string representing the Smart Array device physical location. This string should represent the physical location of the device with which an end-user can uniquely locate the device. Most of these strings will be represented in customer documentation, silkscreen labels, or hood tags. The following table lists the properties implemented. Any combination of the following applicable descriptors could be used to better define the device location.
HP Insight Management WBEM Blade System Lite Provider Overview Description The HP Insight Management Web-Based Enterprise Management (WBEM) Blade System Lite provider extends the management capability of referencing profiles by adding the capability to represent the Distributed Management Task Force (DMTF) Modular System Profile in HP specific ways. While this profile is based on the DMTF Modular System Profile, it does not conform to that profile.
SMX_BladeCSLocation SMX_BladeCSElementLocation The tables in the following sections describe the properties of the supported classes. The classes are categorized by the class or superclass that defines the property, the first column is the Property Name (including type and units) and the second column describes how the provider determines the properties implementation.
Property Name Property Implementation OperationalStatus 0 2 3 6 StatusDescriptions StatusDescriptions[0] per OperationalStatus[0]: Server Blade Enclosure and Onboard Administrator status: Unknown Server Blade Enclosure and Onboard Administrator status: OK Server Blade Enclosure and Onboard Administrator status: Degraded Server Blade Enclosure and Onboard Administrator status: Error HealthState 0 (Unknown), enclosure status: Unknown 5 (OK), enclosure status: OK 10 (Degraded/Warning), enclosure status:
Property Name OtherIdentifyingInfo Property Implementation OtherIdentifyingInfo[0]: Where: is the blade enclosure product ID. OtherIdentifyingInfo[1]: : Where: is the blade enclosure model string; and Serial_Number_String> is the blade enclosure serial number string. Name Text description of the modular system enclosure. The DNS name is populated if available.
Property Name Caption Property Implementation A caption for the class, for example: Server Blade Enclosure Collection GroupOperationalStatus Describes the group operational status of the blade enclosure collection. The group operational status represents the ‘worst-of’ algorithm for all individual enclosure statuses in HP_BladeEnclosureCS.OperationalStatus[0].
SMX_MemberOfBladeEnclosureCollection Class The SMX_MemberOfBladeEnclosureCollection class implements the HP_MemberOfBladeEnclosureCollection class and associates the enclosure’s computer system instance to the blade enclosure collection instance. The following table lists the properties implemented.
Property Name Property Implementation Enclosure Firmware. ElementName OA CIM_ManagedSystemElement A description of the class. For example, if enclosure name exists: Name HP BladeSystem enclosure otherwise: HP BladeSystem enclosure (OK), normal operation OperationalStatus 2 StatusDescriptions Server Blade Enclosure Firmware status: OK HealthState 5 (OK), normal operation CIM_LogicalElement CIM_SoftwareIdentity InstanceID Opaque identifier using HPQfor OrgID.
The following table lists the properties implemented.
The following table lists the properties implemented. Property Name Property Implementation CIM_ManagedElement A description of the Blade location. For example: Caption Blade Computer System Bay Location Where: represents the blade bay slot position enclosure labeling. printed on the A description of the Blade location. For example: Description Blade Computer System Bay Location Where: represents the blade bay slot position enclosure labeling.
Element References CIM_ComputerSystem PhysicalLocation References HP_BladeCSLocation Provider Indications Indications Generated by the Provider This provider generates no indications.
HP Insight Management WBEM CPU Provider Overview The HP Insight Management Web-Based Enterprise Management (WBEM) CPU provider implements and extends classes described in this document to model the system processors. Description This provider implements the following profiles and installs the necessary files: Profile Name Organization Version HP CPU Profile (P00106) HP WBEM TC 1.1.0 HP CPU Consolidated Status Profile (P00107) HP WBEM TC 1.0.
SMX_HWThreadComponent SMX_AssociatedCacheMemory SMX_ProcessorCollection SMX_HostedProcessorCollection SMX_MemberOfProcessorCollection SMX_ProcessorChip SMX_RealizesProcessor SMX_SystemPhysicalProcessor SMX_ProcessorLocation SMX_ProcessorElementLocation The tables in the following sections describe the properties of the supported classes.
Property Name Property Implementation CIM_ManagedSystemElement Name Processor in For text representing the CPU location, refer to “Physical Location”.
Property Name Property Implementation (CPU Enabled) (CPU Disabled by User using BIOS Setup) (CPU Disabled By BIOS (POST Error)) (CPU Idle) (Other) CPUStatus 1 2 3 4 7 Family Processor family number from SMBIOS For example, 179 for Intel(R) Xeon(TM) MaxClockSpeed maximum clock speed in MHz For example: 3600 CurrentClockSpeed current clock speed in MHz For example: 3066 DataWidth 32 64 – for x86 processors – for x64 processors AddressWidth 32 64 – for x86 processors – for x64 processors Exter
Property Name Property Implementation Role Processor Role UniqueID Unique identifier for processor HP_Processor SMX_Processor SMX_ProcessorCapabilities Class The SMX_ProcessorCapabilities class extends the CIM_ProcessorCapabilities class to model the processor capabilities. The following table lists the properties implemented.
Property Name Property Implementation CIM_ManagedElement Caption Description Processor:
Core: Where: is the processor number and is the core number.
Property Name Property Implementation CIM_ProcessorCore InstanceID HPQ:SMX_ProcessorCore Proc:
Core: Where: is the processor number and is the CoreEnabledState 2 core number.
Property Name ElementName Property Implementation Processor:
Core: Thread: Where: is the processor number, thread number is the core number, and is the CIM_ManagedSystemElement Name Processor: Core: Thread: Where: is the processor number, thread number OperationalStatus 0 (Unknown) 2 (OK), when CPU is enabled and operational 5 (Predictive Failure), when IML error info logged 6 (Error), when CPU is disabled via POST error 10 (Stopped), when CPU is disabled via R
The following table lists the properties implemented.
Property Name Property Implementation CIM_LogicalElement CIM_EnabledLogicalElement (Not Applicable) EnabledState 5 RequestedState 12 EnabledDefault 2 (Not Applicable) (Enabled) CIM_LogicalDevice SystemCreationClassName SMX_ComputerSystem SystemName Computer system name CreationClassName SMX_CacheMemory DeviceID Proc
, Level Cache Where: is the processor number, is the cache level number, and is the cache type (Data, Instruction, or Unified) Proc , Core , Le
Property Name Property Implementation CIM_Component CIM_SystemComponent CIM_SystemDevice HP_SystemProcessor SMX_SystemProcessor GroupComponent References SMX_ComputerSystem PartComponent References SMX_Processor SMX_ProcessorElementCapabilities Class The SMX_ProcessorElementCapabilities class extends the CIM_ElementCapabilities class and associates SMX_Processor and SMX_ProcessorCapabilities instances. The following table lists the properties implemented.
SMX_HWThreadComponent Class The SMX_HWThreadComponent class extends the CIM_ConcreteComponent class and associates an SMX_ProcessorCore instance with SMX_HardwareThread instances. The following table lists the properties implemented.
Property Name Property Implementation (Unknown) (Other) (Instruction) (Data) (Unified) CacheType 0 1 2 3 4 LineSize Cache line size in bytes ReadPolicy 0 1 2 3 4 5 (Unknown) (Other) (Read) (Read-Ahead) (Read and Read-Ahead) (Determination Per I/O) Associativity 0 1 2 3 4 5 6 7 (Unknown) (Other) (Direct Mapped) (2-way Set-Associative) (4-way Set-Associative) (Fully Associative) (8-way Set-Associative) (16-way Set-Associative) HP_AssociatedCacheMemory SMX_AssociatedProcessorCacheMemory Antecedent
Property Name Property Implementation CIM_Collection CIM_SystemSpecificCollection InstanceID HPQ:SMX_ProcessorCollection-1 HP_GroupSystemSpecificCollection Caption Processor Package Collection GroupOperationalStatus[0] contains the processors consolidated status.
Property Name Property Implementation CIM_Dependency CIM_HostedDependency CIM_HostedCollection HP_GroupHostedCollection SMX_HostedProcessorCollection Antecedent References SMX_ComputerSystem Dependent References SMX_ProcessorCollection SMX_MemberOfProcessorCollection Class The SMX_MemberOfProcessorCollection class extends the CIM_MemberOfCollection class and associates the SMX_ProcessorCollection instance with an SMX_Processor instance. The following table lists the properties implemented.
Property Name Property Implementation OperationalStatus 0 (Unknown) 2 (OK), when CPU is enabled and operational 5 (Predictive Failure), when IML error info logged 6 (Error), when CPU is disabled via POST error 10 (Stopped), when CPU is disabled via RBSU StatusDescriptions StatusDescriptions[0] Unknown.
Property Name Manufacturer Property Implementation Processor manufacturer string from SMBIOS For example: Intel Model Where: Model Version is the processor model number Model Stepping Where: is the processor model stepping number number and is the processor PoweredOn False – if CPU is disabled via RBSU or POST error True – if CPU is enabled CanBeFRUed True CIM_PhysicalComponent RemovalConditions 3 (Removable When Off) CIM_Chip HP_ProcessorChip ProcessorChipRevision S
SMX_SystemPhysicalProcessor Class The SMX_SystemPhysicalProcessor class extends the CIM_Container class and associates the SMX_ComputerSystemChassis instance with SMX_ProcessorChip instances. The following table lists the properties implemented.
Property Name Property Implementation ( Family Model Stepping ) Where : is the processor brand string, is the CPU architecture type, is the processor family number, is the processor model number and is the processor Description stepping number. For example: Intel(R) Xeon(TM) CPU 3.06GHz (x86 Family 15 Model 2 Stepping 7) Manufacturer: Intel(R) Family: Xeon(TM) CPU 3.
Property Name Property Implementation If only socket number is available: LocationInformation[0]: Where: is the socket number If only slot number is available: LocationInformation LocationInfoDesc LocationInformation[0]: Where: is the slot number If both socket and slot numbers are available: LocationInformation[0]: Where: is the socket number LocationInformation[1]: Where: is the slot number.
Physical Location The Processor Physical Location is a string representing the physical location of a physical CPU module or chip. This string should represent the physical location of the device with which an end-user can uniquely locate the device. Most of these strings will be represented in customer documentation, silkscreen labels, or hood tags. The following table lists the properties implemented.
Property Name Property Implementation NetworkAddresses Contains a list of all the IP addresses of the computer system generating the indication. OSType On ESX, 39 (VM). On Linux, 36 (Linux). OSVersion The operating system version of the computer system generating the indication in the following format: .. SystemFirmwareVersion Array of firmware versions of the computer system generating the indication.
Property Name Property Implementation (Processor) EventCategory 2 ProviderName HP Processor RecommendedActions Enable processor via BIOS or EFI HP_AlertIndication Summary CPU has been disabled by BIOS or EFI ProbableCause 1 (Other) HP Insight Management WBEM CPU Provider Overview 84
HP_DeviceIndication: Processor Predicted to fail Property Name Property Implementation CIM_Indication PerceivedSeverity 4 (Minor) CIM_AlertIndication Description CPU Predictive Failure Notification AlertType 5 EventID 3 EventCategory 2 ProviderName HP Processor RecommendedActions Replace the failing processor.
HP Insight Manager WBEM Ethernet Description The HP Insight Management Web-Based Enterprise Management (WBEM) Ethernet Port provider implements and extends Common Information Model (CIM) classes described in this document to model the ethernet port. These classes reside in the local host OS CIM Object Manager (CIM OM) on each individual monitored system and describe the ethernet ports, associated controllers, and logical ethernet interfaces that are available in the system.
SMX_EthernetDevice SMX_EthernetLANEndpoint SMX_EthernetLANHostedAccessPoint SMX_EthernetPortToLANEndpoint SMX_EthernetPortController SMX_EthernetPortControllerPCIDevice SMX_EthernetPortControllerEthernetPort SMX_EthernetPortControllerPhysicalPackage SMX_EthernetControllerPhysicalPackageEthernetController SMX_EthernetControllerLocation SMX_EthernetControllerPhysicalPackageEthernetControllerLocation SMX_IPProtocolEndpoint SMX_IPProtocolBindsToEthe
Property Name Property Implementation For example: Broadcom Corporation NetXtreme BCM5753M Gigabit Ethernet PCI Express (rev 21). A description of the instance with unique port number for each port on a particular controller. Description For example: Ethernet port on ethernet controller . ElementName Same as Caption.
Property Name Property Implementation SystemName SMX_ComputerSystem.Name SystemCreationClassName SMX_ComputerSystem MaxSpeed Current bandwidth in bits per second if port has link (value is 0, otherwise). Typically one of the following: 10000000, 100000000, 1000000000, or 2500000000 CIM_NetworkPort AutoSense Boolean that is true if Ethernet Port can automatically determine speed of comm.
Property Name Property Implementation 56 (10Gbase-CX4) 100 (100Base-FX) 101 (1000Base-SX) 102 (1000Base-SX) 103 (1000Base-LX) 104 (1000Base-CX) 105 (10GBase-SR) 106 (10GBase-SW) 107 (10GBbase-LX4) 108 (10GBase-LR) 109 (10GBase-LW) 110 (10GBase-ER) 111 (10GBase-EW) Capabilities[] Array of 16 bit unsiged integers advertising the capabilities of the EthernetPort: 0 (Unknown) 1 (Other) 2 (AlertOnLan) 3 (WakeOnLan) CapabilityDescriptions[] Capability Descriptions[0] per Capabilities[0].
SMX_EthernetDevice Class The SMX_EthernetDevice class implements the HP_EthernetDevice class and associates the enclosure’s computer system instance to the blade’s computer system instance. The following table lists the properties implemented. Property Name Property Implementation CIM_EthernetDevice GroupComponent Reference to SMX_ComputerSystem (the computer system in which this Ethernet Port resides.) PartComponent Reference to SMX_EthernetPort (the instance of Ethernet Port in this Computer System.
Property Name Property Implementation CIM_LogicalDevice CIM_EnabledLogicalElement CIM_ServiceAccessPoint CreationClassName SMX_EthernetLANEndpoint SystemName SMX_ComputerSystem.Name SystemCreationClassName SMX_ComputerSystem CIM_ProtocolEndpoint Text representing of what the operating system labels this endpoint. Description For example: eth3 LAN Endpoint information for OS Exposed Ethernet Port information.
Property Name Dependent Property Implementation Reference to SMX_EthernetLANEndpoint. SMX_EthernetPortToLANEndpoint Class The SMX_EthernetPortToLANEndpoint class implements the HP_EthernetPortToLANEndpoint class and associates the Ethernet Port instance to its Ethernet LAN Endpoint instance. The following table lists the properties implemented. Property Name Property Implementation CIM_Dependency CIM_DeviceSAPImplementation HP_EthernetPortToLANEndpoint Antecedent Reference to SMX_EthernetPort.
Property Name Property Implementation CIM_LogicalDevice CIM_EnabledLogicalElement CIM_LogicalDevice CreationClassName SMX_EthernetPortController SystemCreationClassName SMX_ComputerSystem SystemName SMX_ComputerSystem.
The following table lists the properties implemented. Property Name Property Implementation CIM_ManagedElement Product name.
Property Name Property Implementation 0 (Unknown) PackageType 1 (Other - more information in OtherPackageType) 9 (Module/Card) HP_EthernetPortPhysicalPackage SMX_EthernetControllerPhysicalPackageEthernetController Class The SMX_EthernetControllerPhysicalPackageEthernetController class implements the HP_EthernetControllerPhysicalPackageEthernetController class and associates an Ethernet Port Controller Physical Package to its logical Ethernet Port Controller.
Property Name Property Implementation For example, for a controller in slot 3 the key would be: FF-FF-FF-FF-FF-03-FF-85 For an embedded controller 2 the key would be: FF-FF-FF-FF-FF-00-02-88 HP_Location 23 (PCI Adapter Slot) ElementLocationTagDesc 18 (Embedded Port) ElementLocationTag Refer to “Physical Location” for more information. Array of numerical enumerators describing values at comparable index in the LocationInformation array index 1, 2, 3, or 4.
Property Name Property Implementation CIM_PhysicalElementLocation HP_EthernetPortControllerPhysicalPackageEthernetControllerLocation Element Reference to SMX_EthernetControllerPhysicalPackage. PhysicalLocation Reference to SMX_EthernetControllerLocation. SMX_IPProtocolEndpoint Class The SMX_IPProtocolEndpoint class implements the HP_IPProtocolEndpoint class and describes capabilities and characteristics of each IP interface in a managed system. The following table lists the properties implemented.
Property Name Value RequestedState 12 (Not Applicable) EnabledDefault 2 (Enabled) CIM_ServiceAccessPoint CreationClassName SMX_IPProtocolEndpoint SystemCreationClassName SMX_ComputerSystem SystemName SMX_ComputerSystem.Name CIM_ProtocolEndpoint 0 (Unknown) 2 (OK) OperationalStatus 3 (Degraded) 6 (Error) CIM_IPProtocolEndpoint How the Address was assigned to this IP Protocol Endpoint.
Property Name Value For example: Opaque Key. Unique scoped instance information HPQ:SMX_IPProtocolEndpoint: concatenated with the class instance id number. 1 (Other) 4096 (IPv4) ProtocolIFType 4097 (IPv6) 4098 (IPv4/IPv6) SubnetMask Text representing the mask of the IPv4 address, if defined; otherwise, 0.0.0.
Property Name Dependent Property Implementation Reference to SMX_IPProtocolEndpoint SMX_EthernetRemoteServiceAccessPoint Class The SMX_EthernetRemoteServiceAccessPoint class implements the HP_RemoteServiceAccessPoint class and describes the managed systems view of the default gateway. NOTE: Currently not implemented on on VMware ESXi platform. The following table lists the properties implemented. Property Name Property Implementation CIM_ManagedElement A unique description of the gateway.
SMX_EthernetRemoteAccessAvailableToIPEndpoint Class The class implements the HP_RemoteAccessAvailableToIPEndpoint class and associates the Default Gateway represented by the SMX_EthernetRemoteServiceAccessPoint instance to the IP Protocol Endpoint that has access to it. NOTE: Currently not implemented on on VMware ESXi platform. The following table lists the properties implemented.
Property Name Property Implementation CIM_ManagedElement Caption For Ethernet Ports, same as associated EthernetPort.Caption. Description A description of the instance with unique port number for each port on a particular controller For example: Ethernet port on ethernet controller ElementName Same as Caption CIM_StatisticalData InstanceId HPQ:SMX_EthernetStatistics: SampleInterval 00000000000000.
SMX_EthernetPortControllerSoftwareIdentity SMX_EthernetPortControllerSoftwareIdentity implements the class CIM_SoftwareIdentity. It represents the adapter driver software of the associated Ethernet Port. Property Name Property Implementation CIM_ManagedElement Caption Ethernet Port Controller Driver Description Device Driver Where: is the product name of the Ethernet Adapter.
Property Name Property Implementation component of the IdentityInfoValue array. [0]: 'CIM:SoftwareFamily' [1]: 'HPQ:SoftwareCategory' IdentityInfoValue[0] Specific identity info strings that map to IdentityInfoType array. [0]: 'HPQ:' [1]: 'NIC' TargetTypes An array of strings that describes the compatible installer(s).
Property Name Property Implementation CIM_ManagedElement Caption Ethernet Adapter Collection Description This is a collection of all Ethernet Ports.
Property Name Property Implementation Antecedent ref:SMX_ComputerSystem Dependent ref:SMX_EthernetCollection CIM_HostedDependency CIM_HostedCollection HP_EthernetGroupHostedCollection SMX_EthernetTeam SMX_EthernetTeam models Ethernet Redundancy Sets (Ethernet Teams). NOTE: Currently not implemented on on VMware ESXi platform.
Property Name GroupOperationalStatus Property Implementation 2 (OK) 3 (Degraded) 6 (Error) HP_EthernetTeam ActiveMaximumTransmissionUnit Current maximum transmission unit in bytes. Speed The current bandwidth of the team in bits per second. TeamCapabilities[] Capabilities of an Ethernet Team. Refer to Windows Ethernet Teaming mof, HP_WinEthRedundancySet.mof For example: Fast Path Failover TeamCurrentOperatingMode Current operating mode of the Ethernet Team. For example: 802.
SMX_HostedEthernetTeam SMX_HostedEthernetTeam associates the Ethernet Teams to the containing Computer System. NOTE: Currently not implemented on on VMware ESXi platform. Property Name Property Implementation CIM_OwningCollectionElement Key:OwnedElement ref:HP_EthernetTeam Key:OwningElement ref:HP_ComputerSystem HP_HostedEthernetTeam SMX_EthernetTeamToLANEndpoint SMX_EthernetTeamToLANEndpoint associates the Ethernet Teams to the Ethernet LAN Endpoints.
Property Name Property Implementation MaxFloodLevel Max number of events within Flood Threshold, default 100 events. MemberJoinedTeam If enabled, an event is generated when an adapter joins a team. Default, disabled. MemberLeftTeam If enabled, an event is generated when an adapter leaves a team. Default, disabled. MemberRoleChanged If enabled, an event is generated when any change in team member role is detected. Default, disabled.
Property Name Property Implementation indication in the following format: ..
Property Name Property Implementation CIM_Alertindication Description If the Network Interface is an Ethernet Port, the Ethernet Port has transitioned from Error to OK. AlertingManagedElement WBEM Path of the SMX_EthernetPort instance AlertingElementFormat 2 (CIMObjectPath) AlertType 2 (Communications Alert) EventID 3 ProviderName HP Ethernet RecommendedActions No action is recommended HP_AlertIndication Summary The interface network connectivity has been restored.
Property Name Property Implementation EventCategory 1 (Other) EventSubCategory Consolidated Status Policy Change ProbableCause 1 (Other) ProbableCauseDescription This group status policy change is caused by activation or deactivation of Status Propagation Filtering for existing managed elements in HP_GroupSystemSpecificCollection. NOTE: Indications 1-3-4 thru 1-3-14 are currently not implemented on on VMware ESXi platform.
Property Name Property Implementation CIM_Alertindication Description An Ethernet team's redundancy has increased. A team member recovered from a failed or degraded state. AlertingManagedElement WBEM Path of SMX_EthernetTeam instance reporting increased redundancy.
Property Name Property Implementation EventSubCategory 12 (Ethernet team) ProbableCause 88 (Loss of Redundancy) ProbableCauseDescription Ethernet Team Redundancy Decreased HP_AlertIndication: Ethernet Team Redundancy Restored Property Name Property Implementation CIM_Indication PerceivedSeverity 2 (Information) CIM_Alertindication Description An Ethernet team's redundancy status changed to Fully Redundant. An Ethernet team member status changed from Error or Degraded to OK.
Property Name Property Implementation AlertType 2 (Communications Alert) EventID 10 ProviderName HP Ethernet RecommendedActions Check the Ethernet Team and Ethernet Team Member status. View the System Event Log for additional information.
HP_AlertIndication: Ethernet Team Member Dropped Property Name Property Implementation CIM_Indication PerceivedSeverity 2 (Information) CIM_Alertindication Description A team member was dropped from the team via the HP Network Configuration Utility (NCU). This is an optional indication that can be disabled via the Ethernet Event Provider settings. AlertingManagedElement WBEM Path of SMX_EthernetTeam instance reporting a dropped team member.
Property Name RecommendedActions Property Implementation No action is recommended.
Property Name Property Implementation Description A new network interface is available. An Ethernet adapter has been added or an Ethernet team or VLAN has been created. This is an optional indication that can be disabled via the Ethernet Event Provider settings. AlertingManagedElement WBEM Path of SMX_EthernetTeam instance reporting network interface available.
Property Name Property Implementation EventCategory 9 (Network Device) EventSubCategory 12 (Ethernet team) ProbableCause 1 (Other) ProbableCauseDescription Ethernet team reported change in number of active members Physical Location The Ethernet Port Physical Location is a string representing the physical location of the Ethernet Port. This string should represent the physical location of the device with which an end-user can uniquely locate the device.
HP Insight Manager WBEM Fibre Channel Host Bus Adapter Provider Description The HP Insight Management Web-Based Enterprise Management (WBEM) Fibre Channel Host Bus Adapter Profile describes the behavior of Fibre Channel host adapters supporting the SCSI (Fibre Channel Protocol) command set. A Fibre Channel (FC) adapter used in a host system is called a Host Bus Adapter (HBA). An HBA is a physical device that contains one or more Fibre Channel ports. A single system can contain one or more HBAs.
SMX_FCHBAPhysicalPackage SMX_FCHBAProduct SMX_FCHBASoftwareIdentityDrv SMX_FCHBAFirmwareIdentityFW SMX_FCHBAFirmwareIdentityBIOS SMX_FCHBAGroupSystemSpecificCollection SMX_FCHBAComputerSystemFCPort SMX_FCHBAPortControllerPCIDevice SMX_FCHBAComputerSystemPortController SMX_FCHBAComputerSystemLogicalPortGroup SMX_FCHBAComputerSystemSoftwareIdentityDrv SMX_FCHBAFCPortFCPortStatistics SMX_FCHBAFCPortLogicalPortGroup SMX_FCHBAPortControllerFCPort SMX_FCHBAPhysical
Property Name Property Implementation 10 (Stopped) StatusDescriptions[0] Unknown OK Stopped Error CIM_LogicalElement CIM_EnabledLogicalElement EnabledDefault 2 (Enabled) EnabledState 5 (Not Applicable) RequestedState 12 (Not Applicable) CIM_Systems CreationClassName SMX_FCHBAComputerSystem NameFormat Other CIM_ComputerSystem Dedicated 0 IdentifyingDescriptions[0] HPQ:GUID OtherIdentifyingInfo[0] GUID SMX_FCHBAFCPort Class The SMX_FCHBAFCPort class implements the HPFCHBA_FCPort class is u
Property Name StatusDescriptions[0] Value Unknown OK-Online Stopped Offline Stopped Bypassed Stopped Diagnostics Stopped Link down Error CIM_LogicalElement CIM_EnabledLogicalElement EnabledDefault 2 (Enabled) EnabledState 5 (Not Applicable) RequestedState 12 (Not Applicable) CIM_LogicalDevice CreationClassName SMX_FCHBAFCPort DeviceID Opaque value. SystemName Opaque value.
Property Name Value One of (in Bits per Second): 0 1000000000 Speed 2000000000 10000000000 UsageRestriction 4 (not restricted) CIM_NetworkPort (FC) LinkTechnology 4 PermanentAddress Port WWN PortNumber Port number. SupportedMaximumTransmissionUnit Port maximum frame size. SMX_FCHBAPortController Class The SMX_FCHBAPortController class represents a logical device corresponding to a hardware network port controller. The following table lists the properties implemented.
Property Name Value CIM_PortController ControllerType 4 (FC) SMX_FCHBAFCPortStatistics Class The SMX_FCHBAFCPortStatistics class represents statistics for a FC port. . The following table lists the properties implemented and the HBAAPI_PORTSTATISTICS prefix refers to the HBA API HBA_PORTSTATISTICS structure. This information comes directly from the HBA and is not altered.
The following table lists the properties implemented. Property Name Value CIM_ManagedElement Description Grouping of all FC Ports for this HBA Caption Logical Port Group ElementName Logical Port Group CIM_Collection CIM_SystemSpecificCollection InstanceID Opaque CIM_LogicalPortGroup Name NodeWWN NameFormat WWN SMX_FCHBAPhysicalPackage Class The SMX_FCHBAPhysicalPackage class represents the physical elements of the associated FC port controller.
Property Name Value SerialNumber Serial Number Tag NodeWWN: Where: is the port controller instance number for the same adapter Version Board Version or N/A when not available CIM_PhysicalPackage RemovalConditions 2 (Not Applicable) SMX_FCHBAProduct Class The SMX_FCHBAProduct class is used to aggregate physical element of the FC HBA.
Property Name Value CIM_ManagedSystemElement NodeWWN Name CIM_LogicalElement CIM_SoftwareIdentity ClassificationDescriptions FCHBA Driver Classifications 2 InstanceID HPQ:NodeWWN: Where: is the port controller instance number for the same adapter Manufacturer Manufacturer VersionString File version of the Driver. (Driver) SMX_FCHBAFirmwareIdentityFW Class The SMX_FCHBAFirmwareIdentityFW class represents adapter firmware associated with the FC port controller.
SMX_FCHBAFirmwareIdentityBIOS Class The SMX_FCHBAFirmwareIdentityBIOS class represents adapter BIOS associated with the FC port controller. The following table lists the properties implemented. Property Name Value CIM_ManagedElement Caption FCHBA Option ROM Description FCHBA Option ROM detail for Where: product name is the Model_Name of the HBA.
Property Name Value Caption FCHBA Consolidated Status Description Consolidated status for HP FC HBAs ElementName FCHBA Consolidated Status CIM_Collection CIM_SystemSpecificCollection Opaque InstanceID HP_GroupSystemSpecificCollection GroupOperationalStatus[0] 0 (Unknown) 1 (Other) 2 (OK) 3 (Degraded) 6 (Error) 10 (Stopped) GroupStatusDescriptions[0] Unknown Other OK Degraded Error Stopped SMX_FCHBAComputerSystemFCPort Class The SMX_FCHBAComputerSystemFCPort class is used to represent an assoc
The following table lists the properties implemented. Property Name Value CIM_Component CIM_SystemDevice SMX_FCHBAComputerSystemPortController GroupComponent Refer to SMX_FCHBAComputerSystem class properties. PartComponent Refer to SMX_FCHBAPortController class properties. SMX_FCHBAPortControllerPCIDevice Class The SMX_FCHBAPortControllerPCIDevice class is used to represent an association between SMX_PCIDevice and SMX_FCHBAPortController. The following table lists the properties implemented.
The following table lists the properties implemented. Property Name Value CIM_Component CIM_SystemDevice SMX_FCHBAComputerSystemSoftwareIdentityDrv InstalledSoftware Refer to SMX_FCHBASoftwareIdentityDrv class properties. System Refer to SMX_FCHBAComputerSystem class properties. SMX_FCHBAFCPortFCPortStatistics Class The SMX_FCHBAFCPortFCPortStatistics class is used to represent an association between SMX_FCHBAFCPort and SMX_FCHBAFCPortStatistics. The following table lists the properties implemented.
Property Name Value CIM_Dependency CIM_ControlledBy SMX_FCHBAPortControllerFCPort Antecedent Refer to SMX_FCHBAPortController class properties. Dependent Refer to SMX_FCHBAFCPort class properties. SMX_FCHBAPhysicalPackagePortController Class The SMX_FCHBAPhysicalPackagePortController class is used to represent an association between SMX_FCHBAPortController and SMX_FCHBAPhysicalPackage. The following table lists the properties implemented.
Property Name Value CIM_Dependency CIM_ElementSoftwareIdentity SMX_FCHBAPortControllerFirmwareIdentityFW Antecedent Refer to SMX_FCHBAFirmwareIdentityFW class properties. Dependent Refer to SMX_FCHBAPortController class properties. SMX_FCHBAPortControllerFirmwareIdentityBIOS Class The SMX_FCHBAPortControllerFirmwareIdentityBIOS class is used to represent an association between SMX_FCHBAPortController and SMX_FCHBAFirmwareIdentityBIOS. The following table lists the properties implemented.
Property Name Value CIM_Dependency CIM_SystemPackaging SMX_FCHBASystemPackaging Antecedent Refer to SMX_FCHBAPhysicalPackage class properties. Dependent Refer to SMX_FCHBAComputerSystem class properties. SMX_FCHBAGroupHostedCollection Class The SMX_FCHBAGroupHostedCollection class is used to represent an association between SMX_ComputerSystem and SMX_FCHBAGroupSystemSpecificCollection. The following table lists the properties implemented.
The following table lists the properties implemented. Property Name Value CIM_ManagedElement CIM_Location NodeWWN:SerialNumber: Where: is the port controller instance number for the same adapter. Name HP_Location ElementLocationTag ElementLocationTagDesc PhysicalPosition Refer to “Physical Location” for more information. 1 (slot) Refer to “Physical Location” for more information.
Property Name OperationalStatus[0] Value 0 (Unknown) 2 (OK-Online) 6 (Error) 10 (Stopped) 11 (In Service) CIM_LogicalElement CIM_EnabledLogicalElement EnabledDefault 2 (Enabled) EnabledState 5 (Not Applicable) RequestedState 12 (Not Applicable) CIM_LogicalDevice CreationClassName SMX_FCHBASCSIProtocolController DeviceID PortWWN SystemName Opaque value SystemCreationClassName SMX_FCHBAComputerSystem CIM_ProtocolController MaxUnitsControlled 255 CIM_SCSIProtocolController SMX_FCHBASCSIProtoc
Property Name Value CIM_ServiceAccessPoint CreationClassName SMX_FCHBASCSIProtocolEndpoint SystemName Opaque value SystemCreationClassName SMX_FCHBAComputerSystem CIM_ProtocolEndpoint 57 (HIPPI Interface) ProtocolIFType CIM_SCSIProtocolController ConnectionType 2 (fibre channel) Role 2 (initiator) SMX_FCHBAComputerSystemSCSIProtocolController SMX_FCHBAComputerSystemSCSIProtocolController is used to represent an association between SMX_FCHBAComputerSystem and SMX_FCHBASCSIProtocolController.
Property Name Value CIM_Dependency CIM_ProtocolControllerForDevice CIM_ProtocolControllerFCPort SMX_FCHBASCSIProtocolControllerFCPort Antecendent ref:SMX_FCHBASCSIProtocolController Dependent ref:SMX_FCHBAFCPort SMX_FCHBASystemServiceAccessPoint SMX_FCHBASystremServiceAccessPoint is used to represent an association between SMX_FCHBAComputerSystem and SMX_FCHBASCSIProtocolEndpoint.
All Systems HP Integrity Cellular Servers PCI Slot= Cabinet= Embedded Controller= Bay= System Mainboard (referring to System Board/motherboard) Chassis= HP BladeServers in C3000 / C7000 Enclosures Blade= (if embedded on System Board) RootPort= (I/O Mezzanine slot num) Mezzanine= Provider Indications Indications Generated by the Provider This provider generates no indications.
HP Insight Management WBEM IML Record Log Provider Overview The HP Insight Management Web-Based Enterprise Management (WBEM) Integrated Management Log (IML) provider implements the server management record log. Description This provider implements the following profiles and installs the necessary files: Profile Name Organization Version HP Record Log Profile (P00109) HP WBEM TC 1.1.
SMX_IMLRecordLog Class The SMX_IMLRecordLog class implements the HP_CommonRecordLog class to model the server management record log. The following table lists the properties implemented.
Property Name LogState Property Implementation 2 (Normal) (Wraps When Full) The IML entries will fill up available IML nonvolatile memory space until no room is left. The oldest log entries will then be deleted as needed to create room for new log entries. 2 OverwritePolicy CIM_RecordLog InstanceID HPQ:SMX_IMLRecordLog:1 HP_CommonRecordLog TimeOfLastChange Time of last log change. The following table lists the methods implemented for the SMX_IMLRecordLog class.
The following table lists the properties implemented. Property Name Property Implementation CIM_ManagedElement Caption IML record log entry Where: is the SMX_IMLLogEntry.RecordID event. Description Description based on specific IML log event. ElementName IML record log entry Where: RecordID is the SMX_IMLLogEntry.RecordID event.
Property Name Property Implementation SystemModel System model number string from SMBIOS. SystemName Computer system name VendorID 0 3 5 (Unknown) (HP) (Compaq) 0 (Unknown) ServerHardwareArchitecture 7 (x86-32) 10 (x86-64) LoggerType 2 (Server) The following table lists the methods implemented for the SMX_IMLLogEntry class. Method Name Method Implementation Refer to HP Record Log profile (P00109).
Antecedent References SMX_IMLRecordLog Dependent References SMX_ComputerSystem Supported indications There are no indications specific to the profile registration implementation.
HP Insight Management WBEM Management Processor Lite Provider The HP Insight Management Web-Based Enterprise Management (WBEM) Management Processor Lite provider extends the management capability of referencing profiles by adding the capability to represent HP Management Processor on HP servers. Description This provider implements the following profiles and installs the necessary files: Profile Name Organization Version HP Management Processor (MP) Lite Profile HP WBEM TC 2.1.
The tables in the following sections describe the properties of the supported classes. The classes are categorized by the class or superclass that defines the property, the first column is the Property Name (including type and units) and the second column describes how the provider determines the properties implementation. When the Property Implementation value is a number, the number given is the default behavior and the Managed Object Format interpretation is within parenthesis.
Property Name Property Implementation Light Out 100 (LO100) (Active) CIM_ManagedSystemElement Enumerators indicating the Management Processor operational status (refer to OperationalStatus mapping table in HP Management Processor Lite Profile for specific descriptions of when each value is populated).
Property Name Property Implementation Descriptive text per OperationalStatus.
Property Name Property Implementation HPQ:SMX_ManagementProcessor:1 CIM_ComputerSystem Dedicated 14 (Management) ResetCapability 4 (Enabled) HP_ManagementProcessor ControllerType Enumerator indicating the model or type of management processor.
Property Name Property Implementation NICCondition Enumerator indicating the condition of the MP-resident network interface connection. 0 (Unknown) 2 (OK) 3 (NIC disabled) 4 (NIC not in operation-alternate host NIC in use) 5 (NIC in operation but disconnected) 6 (Failed) Note: When a Management Processor is disabled (refer to property EnabledState) NICCondition will always report a state of 3 (NIC disabled ). Network communication with the MP is not possible when the MP is disabled.
Property Name Property Implementation HP_ManagementProcessor SMX_MPFirmware Class The SMX_MPFirmware class implements the HP_MPFirmware class to describe management processor firmware The following table lists the properties implemented. Property Name Property Implementation CIM_ManagedElement Caption Short Description of the MP firmware For example: Management Processor Firmware Description Description of the MP firmware.
Property Name Property Implementation IdentityInfoValue Indexed array that provides the values described by the type information stored in the corresponding component of the IdentityInfoType array.
Property Name Property Implementation Describes the group operational status of the management processor collection (refer to HP Management Processor Lite Profile). The group operational status represents the “worst-of” algorithm for all individual MP statuses in HP_ManagementProcessor.OperationalStatus[0].
HP_MPComponentCS GroupComponent References SMX_ComputerSystem PartComponent References SMX_ManagementProcessor SMX_MPMemberOfCollection Class The SMX_MPMemberOfCollection class implements the HP_MPMemberOfCollection class to associate a management processor to the collection to which it belongs. The following table lists the properties implemented.
Property Name Property Implementation CIM_InstalledSoftwareIdentity SMX_MPInstalledFirmwareIdentity System References SMX_ManagementProcessor InstalledSoftware References SMX_MPFirmware SMX_MPConsolidatedStatusView Class HP_ConsolidatedStatusView extends the class CIM_View instances are used to aggregate and model all Consolidated Status information into a instances related to a single subsystem.
Antecedent References HP_ComputerSystem Dependent References SMX_MPConsolidatedStatusView SMX_ManagementController Class The SMX_ManagementController class implements the HP_ManagementController to describe a management controller. The following table lists the properties implemented. Property Name Property Implementation CIM_ManagedElement Caption Short Description of the Management Controller, including the product name and the enabled state of the MP.
Property Name Property Implementation Enumerators indicating the Management Processor operational status (refer to OperationalStatus mapping table in HP Management Processor Lite Profile for specific descriptions of when each value is populated).
Property Name HealthState Property Implementation 0 (Unknown), when OperationalStatus[0]=0 (Unknown) 5 (OK), normal operation 10 (Degraded/Warning), when OperationalStatus[0]=3 (Degraded) 20 (Major failure), when OperationalStatus[0]=6 (Error) Note: When a Management Processor is disabled (refer to property EnabledState) HealthState will always report a state of 5 (OK) so as not to contribute negatively to overall system status.
SMX_MPControllerMP GroupComponent References SMX_ManagementProcessor PartComponent References SMX_ManagementController SMX_MPControllerPCIDevice Class The SMX_MPControllerPCIDevice class implements the CIM_ConcreteIdentity class to associate a management controller to its corresponding PCI Devices. The following table lists the properties implemented.
Property Name Property Implementation SystemFirmwareVersion Array of firmware versions of the computer system generating the indication. SystemSerialNumber Serial number of the computer system generating the indication. SystemProductID Product ID of the computer system generating the indication. SystemModel Model name of the computer system generating the indication. SystemGUID Platform GUID of the computer system generating the indication.
Property Name Property Implementation status is included in collection operational status.” HP_AlertIndication Summary “Consolidated View Class Collection operational status policy has changed “ EventCategory 1 (Other) ProbableCause 1 (Other) ProbableCauseDescription “This group status policy change is a caused by one of two changes: 1. Additional or removal of managed elements to an HP_GroupSystemSpecificCollection 2.
Property Name Property Implementation EventCategory 1 (Other) OtherEventCategory “View Class Status Changed” ProbableCause 1 (Other) ProbableCauseDescription “Operational Status of participating members in this collection have transitioned to OK from Degraded or Error state. These Operational Status changes could have also affected the HP_GroupSystemSpecificCollection’s operational status.
Property Name Property Implementation ProbableCause 1 (Other) ProbableCauseDescription “Operational Status of participating members in this collection have transitioned to Degraded state. These Operational Status changes could have also affected the HP_GroupSystemSpecificCollection’s operational status.” HP_AlertStatusIndication: Consolidated Status Changed-Error The following table describes one of the conditional Consolidated Status Changed indications.
Property Name Property Implementation collection to transition to Error.
HP Insight Management WBEM PCI Device Provider Overview Description The HP Insight Management Web-Based Enterprise Management (WBEM) PCI Device provider implements the profiles listed to support PCI devices installed on HP servers. The following table details the profiles implemented and files installed by this provider. Implemented Profiles DMTF: PCI Device Profile (DSP1075) 1.0.0a 09/2007 DMTF: Physical Asset Profile HP: Location Profile 1.2.
Property Name Property Implementation Capabilities Contains the capabilities of the PCI device.13 (PCI Express device) 5 (PCI-X capable device) CapabilityDescriptions Descriptions of capabilities. ClassCode Register of 8 bits that identify the basic function of the PCI device. This property is only the upper byte (offset 0Bh) of the 3-byte ClassCode field. Note the ValueMap array of the property specifies the decimal representation of this information.
Property Name Property Implementation Tag “PCI Card ” Description “PCI Card ” ElementName “PCI Card ” CIM_PhysicalPackage RemovalConditions 2 (Not Applicable) PackageType 9 (Module/Card) VendorCompatibilityStrings “HPQ:PCICard” CIM_Card HostingBoard False HP_PCICard SMX_PCISlot Property Name Property Implementation CIM_ManagedElement Caption Same as Name.
Property Name Property Implementation ConnectorType 43 (PCI) – if this is a 33 MHz PCI slot 80 (PCI-66MHZ) – if this is a 66 MHz PCI slot 98 (PCI-X) – if this is a PCI-X slot 1 (Other) – if this is a PCI Express slot ConnectorDescription Only initialized if ConnectorType == 1 (Other): “PCI Express” – if this is a PCI Express slot or “PCI Express Mezzanine” if mezzanine slot in a blade, otherwise this property is not set OtherTypeDesciption Deprecated in favor of ConnectorDescription CIM_Slot Number
Property Name PartComponent Property Implementation References SMX_PCIDevice SMX_PCISlotLocation Property Name Property Implementation CIM_ManagedElement Caption Same as ElementLocationTag. Description Same as ElementLocationTag. ElementName Same as ElementLocationTag. CIM_Location Name Unique identifier of the form: HPQ:SMX_PCISlotLocation: PhysicalPosition Opaque key.
Array of numerical enumerators describing values at comparable index in the LocationInformation array index 1,2, 3, or 4. LocationInfoDesc[0] Slot). LocationInfoDesc per LocationInformation[0] 3 (PCI Additional enumerators for Cellular servers (Cabinet) 6 (Chassis) 7 Additional enumerators for HP BladeSystem servers 14 (Blade) 1 (Mezzanine) LocationInformation Array of text values representing the location components that describe this PCI Slot location. LocationInfoDesc[0] per LocationInfornation[0].
All Systems HP Integrity Cellular Servers HP BladeServers in C3000 / C7000 Enclosures Slot= Cabinet= Blade= Embedded Controller= Bay= RootPort= (if embedded on System Board) Chassis= Mezzanine= (I/O Mezzanine slot num) Mezzanine= Provider Indications Indications Generated by the Provider This provider generates no indications.
HP Insight Management Power Supply Provider Overview The HP Insight Management Web-Based Enterprise Management (WBEM) Power Supply provider implements the HP Power Supply profile to model power supplies in servers. Description This provider implements the following profiles and installs the necessary files: Profile Name Organization Version HP Power Supply Profile HP WBEM TC 1.3.1 (P103) HP Location Profile HP WBEM TC 1.2.0 (P124) HP Power Supply Physical Asset Profile HP WBEM TC 1.0.
SMX_MemberOfPowerRedundancy SMX_HostedPowerRedundancySet SMX_MemberOfPowerCollection SMX_HostedPowerCollection SMX_SystemPowerSupply SMX_PowerSupplyLocation SMX_PowerSupplyElementLocation SMX_PowerSupplyModule SMX_SystemPhysicalPowerSupply SMX_RealizesPowerSupply SMX_PowerMeter SMX_AssociatedPowerMeter SMX_SystemPowerMeter SMX_PowerControllerFirmware SMX_PowerControllerInstalledFirmwareIdentity SMX_PowerControllerElementFirmwareIdentity The tables in the following sections
Property Name Property Implementation Description of this power supply, including ElementName, PowerSupplyType and StatusDescription[0] and StatusDescription[1]. For example: Description ElementName Elementname provides power for PowerSupplyType.StatusDescription Where: Elementname represents the value of ElementName, PowerSupplyType represents the corresponding string value of the PowerSupplyType enumeration, and StatusDescription represents the value of StatusDescriptions[0]and StatusDescription[1].
Property Name Property Implementation CIM_LogicalDevice CreationClassName SMX_PowerSupply DeviceID Unique identifier for this power supply instance. SystemCreationClassName SMX_ComputerSystem.CreationClassName SystemName SMX_ComputerSystem.
Property Name Property Implementation GroupOperationalStatus[0] Represents the most severe power redundancy status and non-fault tolerant power supply operational status: 0 (Unknown) – if power collection status is unknown; 2 (OK) – if power supplies are operating properly; 3 (Degraded) – if no SMX_PowerSupply.OperationalStatus[0] for all non-fault tolerant power supplies report 6 (Error) and SMX_PowerRedundancySet.
Property Name ElementName Property Implementation User printable name for this power redundancy set. For example: Power Redundancy Set Where: represents the number of the redundancy set instance. CIM_SystemSpecificCollection InstanceID Unique identifier for this power redundancy instance. CIM_RedundancySet MaxNumberSupported Represents the maximum number of power supplies supported for this redundancy set. MinNumberNeeded Represents the minimum number of power supplies needed to function.
The following table lists the properties implemented. Property Name Property Implementation Collection References HP_PowerRedundancySet Included Writable Boolean property indicating if the power supply instance referenced by Member will contribute status to the HP_PowerCollection. Property can be modified using the ModifyInstance() intrinsic method.
The following table lists the properties implemented. Property Name Property Implementation Antecedent References HP_ComputerSystem Dependent References HP_PowerCollection SMX_SystemPowerSupply Class The SMX_SystemPowerSupply class is used to represent an association between the HP_PowerSupply class and the computer system that contains this power supply. The following table lists the properties implemented.
Property Name Property Implementation HP_Location Location string based on ElementLocationTagDesc. For example, on HP Proliant: ElementLocationTag Power Supply Where : represents the power supply position printed on the system. ElementLocationTagDesc On HP Proliant: 0 (HoodTag) LocationInfoDesc An array of tags describing the corresponding location path information contained in the LocationInformation property array.
Property Name Description ElementName Property Implementation Description of this power supply module, including ElementName, Type and Status. For example: ElementName provides power for PowerSupplyType. StatusDescription Where: ElementName represents the value of ElementName, PowerSupplyType represents the corresponding string value of the PowerSupplyType enumeration and StatusDescription represents the value of StatusDescriptions[0].
Property Name Property Implementation Unique identifier for this power supply instance. Tag CIM_PhysicalPackage RemovalConditions 0 3 4 (Unknown) (Removable when off) (Removable when on or off) PackageType 6 (PowerSupply) SMX_SystemPhysicalPowerSupply Class The SMX_SystemPhysicalPowerSupply class extends the CIM_Container class and association of the HP_ComputerSystemChassis instance with HP_PowerSupplyModule. The following table lists the properties implemented.
The following table lists the properties implemented. Property Name Property Implementation Antecedent References HP_PowerSupplyModule Dependent References HP_PowerSupply SMX_PowerSupplySlot Class The SMX_PowerSupplySlot class is used to model physical power supply slots on servers. The following table lists the properties implemented. Property Name Property Implementation CIM_ManagedElement Caption Short description of this power supply slot.
SMX_SystemPowerSupplySlot Class The SMX_SystemPowerSupplySlot class extends the CIM_Container class and association of the HP_ComputerSystemChassis instance with HP_PowerSupplySlot. The following table lists the properties implemented.
Property Name ElementName Property Implementation Short description of this power utilization sensor using the name of the power supply displayed by the MP or iLO. For example: Power utilization sensor for Power Supply 1 CIM_ManagedSystemElement OperationalStatus[0] 2 (OK) – if power utilization sensor is operating properly; StatusDescriptions[0] Description of the status of the power utilization sensor corresponding to the OperationalStatus.
SMX_SystemPowerMeter SMX_SystemPowerMeter class and associates the HP_ComputerSystem instance with HP_PowerMeter. Property Name Property Implementation GroupComponent References HP_ComputerSystem PartComponent References HP_PowerMeter SMX_AssociatedPowerMeter The SMX_AssociatedPowerMeter class associates the HP_PowerSupply instance with HP_PowerMeter instance.
Property Name Property Implementation CIM_LogicalElement CIM_SoftwareIdentity InstanceID Opaque key Manufacturer Hewlett-Packard Company Classifications 10 (Firmware) ClassificationDescriptions Power controller firmware IsEntity TRUE VersionString The firmware version string MajorVersion The firmware major version number, if any MinorVersion The firmware minor version number, if any RevisionNumber The firmware revision number number, if any SMX_PowerControllerElementFirmwareIdentity The
HP Integrity server platforms implement power supply related indications in the SMX IPMI Record Log provider. Provider Indication Common Properties Property Name Property Implementation CIM_Indication IndicationIdentifier GUID string generated at the time of indication. IndicationTime Time of indication. CIM_AlertIndication EventTime Time of the event or time of the indication if event time unknown. SystemName SMX_ComputerSystem.Name SystemCreationClassName SMX_ComputerSystem.
HP_DeviceIndication: Power Supply AC Input Loss Property Name Property Implementation CIM_Indication PerceivedSeverity 5 (Major) CIM_AlertIndication Description A power supply has failed – input power lost. PowerSupplyCaption Where: PowerSupplyCaption is the SMX_PowerSupply.
Property Name Property Implementation supply was removed intentionally. HP_AlertIndication Summary Power supply removed EventCategory 16 ProbableCause 1 (System Power) (Other) ProbableCauseDescription Power Supply Removed HP_DeviceIndication: Power Supply Inserted Property Name Property Implementation CIM_Indication PerceivedSeverity 2 (Information) CIM_AlertIndication Description A power supply has been inserted. PowerSupplyCaption Where: PowerSupplyCaption is the SMX_PowerSupply.
Property Name Property Implementation SMX_PowerSupply.Caption for the power supply that has failed. AlertingManagedElement WBEM Path of SMX_PowerSupply instance representing the failed power supply. AlertingElementFormat 2 (CIMObjectPath) AlertType 5 (Device Alert) EventID 3 ProviderName HP Power RecommendedActions Check the failed power supply and replace if necessary.
. Property Name Property Implementation ProbableCauseDescription Power supply degraded HP_DeviceIndication: Power Supply Repaired Property Name Property Implementation CIM_Indication PerceivedSeverity 2 (Information) CIM_AlertIndication Description A power supply has been repaired. PowerSupplyCaption Where: PowerSupplyCaption is the SMX_PowerSupply.Caption for the power supply that has been repaired.
Property Name Property Implementation (Device Alert) AlertType 5 EventID 5 ProviderName HP Power RecommendedActions No action is recommended.
HP_DeviceIndication: Power Supply Redundancy Failed Important: This indication is not supported on HP Proliant systems since redundancy set failure, which is failure beyond redundancy lost, will cause system shutdown. Property Name Property Implementation CIM_Indication PerceivedSeverity 5 (Major) CIM_AlertIndication Description Power redundancy has been lost. RedundancySetCaption Where: RedundancySetCaption represents the SMX_PowerRedundancySet.Caption for the redundancy set that failed redundancy.
Property Name Property Implementation power redundancy set with restored redundancy. AlertingElementFormat 2 (CIMObjectPath) AlertType 5 (Device Alert) EventID 8 ProviderName HP Power RecommendedActions No action is recommended.
HP Insight Management WBEM Profile Registration Provider Description The HP Insight Management Web-Based Enterprise Management (WBEM) Management Profile Registration provider extends the management capability of referencing profiles by adding the capability to represent HP Management Processor on HP servers. This provider implements the following profiles and installs the necessary files: Profile Name Organization Version HP Profile Registration Profile (P00100) HP WBEM TC 2.0.
SMX_RegisteredProfile Class The SMX_RegisteredProfile class implements the Distributed Management Task Force (DMTF) and Storage Networking Industry Association (SNIA) SMI-S storage profiles. The following table lists the properties implemented. Property Name Property Implementation CIM_ManagedElement Caption The DMTF Profile table lists the property values for this class. Description The DMTF Profile table lists the property values for this class.
OS Status 1.0.0 DMTF OS Status Profile Record Log 1.0.0 DMTF Record Log Profile Ethernet Port 1.0.0 DMTF Ethernet Port Profile IP Interface 1.0.1 DMTF IP Interface Profile Sensors 1.0.1 DMTF Sensors Profile PCI Device 1.0.0 DMTF PCI Device Profile Software Inventory 1.0.0 DMTF Software Inventory Profile Profile Registration 1.0.0 DMTF Profile Registration Profile The following table lists all possible SNIA Profiles.
RegisteredName HP Fan Physical Asset Registered Version 1.0.0 Caption/Description/ElementName HP Fan Physical Asset Profile HP Power Supply Physical 1.0.0 Asset HP Power Supply Physical Asset Profile HP CPU Consolidated Status 1.0.0 HP CPU Consolidated Status Profile HP Sensors 1.0.0 HP Sensors Profile HP Record Log 1.0.0 HP Record Log Profile HP Software Inventory 1.0.0 HP Software Inventory Profile HP Blade System Lite 2.0.3 HP Blade system Lite Profile HP Management Processor Lite 2.
SMX_ReferencedProfile Antecedent References CIM_RegisteredProfile (referenced) Dependent References CIM_RegisteredProfile (referenced) SMX_PRPBaseServerECTP Class The SMX_PRPBaseServerECTP class extends the CIM_ElementConformsToProfile class and associates the Base Server registered profile with the HP specific central class that defined the implementation of the profile. The following table lists the properties implemented.
SAS HBA Provider Datasheet version1.04 The following chapters define the supported properties for the SAS HBA provider. For details of each property, see the HP SAS HBA profile (P00122) and associated MOF file. 1-1-2 SMX_SASArraySystem SMX_SASArraySystem represents the top level system. There is one instance per HBA.
Table Class: SMX_SASArrayController (CIM_ComputerSystem) Property name Property implementation CIM_ManagedElement ElementName Controller name and location For example, HP 8 INT Port SAS/SATA HBA in Slot 3 CIM_ManagedSystemElement OperationalStatus[0] Status for Array Controller 0 (Unknown) 2 (OK) 6 (Error) CIM_LogicalElement CIM_EnabledLogicalElement EnabledDefault 2 (Enabled) EnabledState 5 (Not Applicable) RequestedState 12 (Not Applicable) CIM_System CreationClassName SMX_SASArrayContr
Table Class: SMX_SASStorageVolume (CIM_StorageVolume) Property name Property implementation RequestedState 12 (Not Applicable) CIM_LogicalDevice CreationClassName SMX_SASStorageVolume DeviceID Opaque Key SystemCreationClassName SMX_SASArraySystem SystemName SMX_SASArraySystem.Name CIM_StorageExtent ConsumableBlocks Total Number of blocks on the volume.
Table Class: SMX_SASDiskDrive (CIM_DiskDrive) Property name Property implementation CIM_ManagedElement ElementName Disk location For example, Port 1E Box 1 Bay 2 CIM_ManagedSystemElement Name SAS Address OperationalStatus[0] Operational Status for the disk drive 0 (Unknown) 2 (OK) 5 (Predictive Failure) 6 (Error) CIM_LogicalElement CIM_EnabledLogicalElement EnabledDefault 2 (Enabled) EnabledState 5 (Not Applicable) RequestedState 12 (Not Applicable) CIM_LogicalDevice CreationClassNam
Table Class: SMX_SASStorageExtent (CIM_StorageExtent) Property name Property implementation CIM_ManagedElement ElementName Disk location For example, Port 1E Box 1 Bay 2 CIM_ManagedSystemElement Name Serial number of drive OperationalStatus[0] Operational Status for the disk drive 0 (Unknown) 2 (OK) 5 (Predictive Failure) 6 (Error) CIM_LogicalElement CIM_EnabledLogicalElement EnabledDefault 2 (Enabled) EnabledState 5 (Not Applicable) RequestedState 12 (Not Applicable) CIM_LogicalDevic
Table Class: SMX_SASDiskDriveFirmware (CIM_SoftwareIdentity) Property name Property implementation ElementName TargetType value CIM_ManagedSystemElement Name Disk Drive Firmware CIM_LogicalElement Caption Disk Drive Firmware Description Disk Drive Firmware CIM_SoftwareIdentity ClassificationDescriptions[0] Disk Drive Firmware Classifications[0] 10 (Firmware) InstanceID Opaque key Manufacturer Disk drive vendor string IdentityInfoType [0]CIM:SoftwareFamily [1]HPQ:SoftwareCategory Identity
Table Class: SMX_SASPhysicalPackage (CIM_PhysicalPackage) Property name Property implementation RemovalConditions 2 (Not Applicable) SMX_SASPhysicalPackage 1-1-9 SMX_SASDiskPhysicalPackage SMX_SASDiskPhysicalPackage represents the physical aspects of the disk drive. There is one instance per disk drive.
Table Class: SMX_SASPortController (CIM_PortController) Property name Property implementation CIM_ManagedElement ElementName Controller name and location, for example, HP 8 INT Port SAS/SATA HBA in Slot 3 CIM_ManagedSystemElement CIM_LogicalElement CIM_EnabledLogicalElement EnabledDefault 2 (Enabled) EnabledState 5 (Not Applicable) RequestedState 12 (Not Applicable) CIM_LogicalDevice CreationClassName SMX_SASPortController DeviceID Controller serial number SystemCreationClassName SMX_SASArray
Table Class: SMX_SASDAPort (CIM_DAPort) Property name Property implementation EnabledState 5 (Not Applicable) RequestedState 12 (Not Applicable) CIM_LogicalDevice CreationClassName SMX_SASDAPort DeviceID Opaque key SystemCreationClassName SMX_SASArraySystem SystemName SMX_SASArraySystem.Name CIM_LogicalPort UsageRestriction 2 (Front-End Only) CIM_DAPort PortType 82 (PCI) SMX_SASDAPort 1-1-12 SMX_SASFirmware SMX_SASFirmware represents the firmware installed on a SAS HBA controller.
Table Class: SMX_SASFirmware (CIM_SoftwareIdentity) Property name Property implementation SMX_SASFirmware 1-1-13 SMX_SASPrimordialPool SMX_SASPrimordialPool represents the total raw storage managed by the array controller that is assigned to Raid volumes. Table Class: SMX_SASPrimordialPool (CIM_StoragePool) Property name Property implementation CIM_ManagedElement ElementName Controller name and location: pool identifier.
Table Class: SMX_SASPrimordialPoolNoRaid (CIM_StoragePool) Property name Property implementation Primordial TRUE RemainingManagedSpace 0 TotalManagedSpace Total raw space available to controller. This is calculated by summing the total space on all non raid drives connected to this controller. SMX_SASPrimordialPoolNoRaid 1-1-15 SMX_SASStoragePool SMX_SASStoragePool represents any concrete storage pools created on an array controller. There is one instance per HBA for this implementation.
Table Class: SMX_SASStorageSetting (CIM_StorageSetting) Property name Property implementation InstanceID Opaque key CIM_StorageSetting ChangeableType 0 (Not Changeable) DataRedundancyGoal 1 (RAID 0) 2 (RAID 1) DataRedundancyMax 1 (RAID 0) 2 (RAID 1) DataRedundancyMin 1 (RAID 0) 2 (RAID 1) DeltaReservationGoal 0 DeltaReservationMax 0 DeltaReservationMin 0 NoSinglePointOfFailure FALSE—RAID 0 TRUE—RAID 1 PackageRedundancyGoal 0 (RAID 0) 1 (RAID 1) PackageRedundancyMax
Table Class: SMX_SASSCSIProtocolEndpoint (CIM_SCSIProtocolEndpoint) Property name Property implementation SystemCreationClassName SMX_SASArraySystem SystemName SMX_SASArraySystem.Name CIM_ProtocolEndpoint ProtocolIFType 0 (Unknown) CIM_SCSIProtocolEndpoint ConnectionType 1 (Other) OtherConnectionType PCI Role 4 (Both Initiator and Target) SMX_SASSCSIProtocolEndpoint 1-1-18 SMX_SASSCSIProtocolController SMX_SASSCSIProtocolController represents a view a SCSI resources on the controller.
1-1-19 SMX_SASStorageRedundancySet SMX_SASStorageRedundancySet represents disk sparing aspect of a RAID configuration. There is an instance for every raid set that has spare drives configured.
1-1-21 SMX_SASArraySystemLocation SMX_SASArraySystemLocation represents a location string for the HBA.
Table Class: SMX_SASDiskDriveLocation (HP_Location) Property name Property implementation HP_Location ElementLocationTag Bay Number or SCSI ID of Disk ElementLocationTagDesc 20 (Bay) or 21 (SCSI ID) SMX_SASDiskDriveLocation 1-1-23 SMX_SASStorageCapabilities SMX_SASStorageCapabilities represents the possible capabilities of a Storage Pool.
Table Class: SMX_SASStorageCapabilities (CIM_StorageCapabilities) Property name Property implementation PackageRedundancyDefault 0 (When Pool is NonRAID) 1 (When number of drives = 1) 2 (When number of drives > 1) PackageRedundancyMax 0 (When Pool is NonRAID) 1 (When number of drives = 1) 2 (When number of drives > 1) PackageRedundancyMin 0 SMX_SASStorageCapabilities 1-1-24 SMX_SASProduct SMX_SASProduct represents the marketing information for the HBA.
Table Class: SMX_SASDriveCage (CIM_PhysicalPackage) Property name Property implementation Manufacturer Drive Cage Vendor string Model Drive Cage Model string PartNumber N/A–Not available in this implementation Tag Opaque key SerialNumber Enclosure Serial number Version N/A–Not available in this implementation CIM_PhysicalPackage RemovalConditions 2 (Not Applicable) HP_DriveCage BackplaneSpeed See profile DriveBays See profile DuplexLocation See profile SMX_SASDriveCage 1-1-26 SMX_SASEn
1-1-27 SMX_SASStorageEnclosure SMX_SASStorageEnclosure represents the physical chassis for an internal or externally attached enclosure.
Table Class: SMX_SASStorageEnclosureProcessor (CIM_ComputerSystem) Property name Property implementation ElementName Port: Box: , where is the port and is the box number CIM_ManagedSystemElement OperationalStatus[0,1, 2, 3 ] Operational status for enclosure and associated power supplies, fans, and sensors. The use of OperationalStatus is described in the HP Storage Enclosure Profile.
Table Class: HPAS_StorageEnclosureLocation (HP_Location) Property name Property implementation Description Enclosure location For example, Port 1E Box 1 Name Key PhysicalPosition Key ElementLocationTag Unknown for Undetermined External for external enclosures Internal for drive cages located within the host chassis ElementLocationTagDesc 19 (Box) 1-1-30 SMX_SASDriveCageDiskPhysicalPackage (Association) Table Class: SMX_SASDriveCageDiskPhysicalPackage (CIM_Container) Property name Proper
Table Class: SMX_SASArraySystemStorageEnclosureProcessor (CIM_SystemComponent) Property name Property implementation PartComponent SMX_SASStorageEnclosureProcessor 1-1-34 SMX_SASStorageEnclosureProcessorEnclosureFirmwar e (Association) Table Class: SMX_SASStorageEnclosureProcessorEnclosureFirmware (CIM_ElementSoftwareIdentity) Property name Property implementation Antecedent SMX_SASEnclosureFirmware Dependent SMX_SASStorageEnclosureProcessor ElementSoftwareStatus ElementSoftwareStatus[0]: 2 (C
1-1-38 SMX_SASPrimordialPoolNoRaidStorageCapabilities (Association) Table Class: SMX_SASPrimordialPoolNoRaidStorageCapabilities (CIM_ElementCapabilities) Property name Property implementation Capabilities SMX_SASStorageCapabilities ManagedElement SMX_SASPrimordialPoolNoRaid 1-1-39 SMX_SASStoragePoolStorageCapabilities (Association) Table Class: SMX_SASStoragePoolStorageCapabilities (CIM_ElementCapabilities ) Property name Property implementation Capabilities SMX_SASStorageCapabilities ManagedElem
Table Class: SMX_SASArraySystemStorageVolume (CIM_SystemDevice) Property name Property implementation GroupComponent SMX_SASArraySystem PartComponent SMX_SASStorageVolume 1-1-44 SMX_SASArraySystemStorageExtent (Association) Table Class: SMX_SASArraySystemStorageExtent (CIM_SystemDevice) Property name Property implementation GroupComponent SMX_SASArraySystem PartComponent SMX_SASStorageExtent 1-1-45 SMX_SASArraySystemDAPort (Association) Table Class: SMX_SASArraySystemDAPort (CIM_SystemDevice
Table Class: SMX_SASArraySystemStoragePool (CIM_HostedStoragePool) Property name Property implementation GroupComponent SMX_SASArraySystem PartComponent SMX_SASStoragePool 1-1-49 SMX_SASComputerSystemArraySystem (Association) Table Class: SMX_SASComputerSystemArraySystem (CIM_ComponentCS) Property name Property implementation GroupComponent HP_ComputerSystem PartComponent SMX_SASArraySystem 1-1-50 SMX_SASArraySystemArrayController (Association) Table Class: SMX_SASArraySystemArrayController (C
1-1-54 SMX_SASPrimordialPoolNoRaidStorageExtent (Association) Table Class: SMX_SASPrimordialPoolNoRaidStorageExtent (CIM_ConcreteComponent) Property name Property implementation GroupComponent SMX_SASPrimordialPoolNoRaid PartComponent SMX_SASStorageExtent 1-1-55 SMX_SASStorageSpecificCollectionArraySystem (Association) Table Class: SMX_SASStorageSpecificCollectionArraySystem (CIM_MemberOfCollection) Property name Property implementation Collection SMX_SASStorageSpecificCollection Member SMX_SAS
Table Class: SMX_SASSCSIProtocolControllerStorageVolume (CIM_ProtocolControllerForUnit) Property name Property implementation DeviceAccess 2 (Read Write) 1-1-59 SMX_SASFirmwareArraySystem (Association) Table Class: SMX_SASFirmwareArraySystem (CIM_ElementSoftwareIdentity) Property name Property implementation Antecedent SMX_SASFirmware Dependent SMX_SASArraySystem ElementSoftwareStatus ElementSoftwareStatus[0]: 2 (Current) ElementSoftwareStatus[1]: 6 (Installed) 1-1-60 SMX_SASDiskDriveDiskDri
Table Class: SMX_SASPrimordialPoolStoragePool (CIM_AllocatedFromStoragePool) Property name Property implementation Antecedent SMX_SASPrimordialPool Dependent SMX_SASStoragePool SpaceConsumed Bytes consumed by storage pool 1-1-64 SMX_SASSpareExtentStorageRedundancySet (Association) Table Class: SMX_SASSpareExtentStorageRedundancySet (CIM_IsSpare) Property name Property implementation Antecedent SMX_SASStorageExtent Dependent SMX_SASStorageRedundancySet 1-1-65 SMX_SASStorageExtentStorageVolume
Table Class: SMX_SASPhysicalPackageArraySystem (CIM_ComputerSystemPackage) Property name Property implementation Antecedent SMX_SASPhysicalPackage Dependent SMX_SASArraySystem 1-1-69 SMX_SASPhysicalPackageArraySystemLocation (Association) Table Class: SMX_SASPhysicalPackageArraySystemLocation (CIM_PhysicalElementLocation) Property name Property implementation Element SMX_SASPhysicalPackage Physical Location SMX_SASArraySystemLocation 1-1-70 SMX_SASDiskPhysicalPackageDiskDriveLocation (Associat
Table HP_DeviceIndication: SAS HBA status OK Property name Property implementation CIM_AlertIndication Description A SAS/SATA HBA status has changed from non-OK to OK. AlertingManagedElement WBEM Path of controller AlertingElementFormat 2 (CIMObjectPath) AlertType 5 (Device Alert) EventID 1 EventTime Time of the event or time of the indication if event time unknown ProviderName HP SAS RecommendedActions No action is recommended.
Table HP_DeviceIndication: SAS HBA status OK Property name Property implementation BladeName * HP_ComputerSystem.Name EnclosureName * HP_BladeEnclosureCS.
Table HP_DeviceIndication: SAS HBA in Error state Property name Property implementation SystemCreationClassName CreationClassName of the computer system generating the indication HP_AlertIndication Summary HBA status Error EventCategory 11 (I/O Adapter) ProbableCause 2 (Adapter/Card Error) ProbableCauseDescription HBA Status Changed to Error ProviderVersion Provider version generating the indication in the format, ...
Table HP_DeviceIndication: SAS HBA in Error state Property name Property implementation HWManufacturer Controller Manufacturer string HWSerialNumber Controller Serial Number HP_DeviceIndication DeviceModel Controller Model string 1-2-3 Physical Drive Status OK Table HP_DeviceIndication: Physical Drive status OK Property name Property implementation CIM_Indication IndicationIdentifier GUID string generated at the time of indication PreceivedSeverity 2 (Informational) IndicationTime Time of ind
Table HP_DeviceIndication: Physical Drive status OK Property name Property implementation SystemFirmwareVersion Firmware version of the computer system generating the indication SystemSerialNumber Serial number of the computer system generating the indication SystemProductID Product ID of the computer system generating the indication SystemModel Model name of the computer system generating the indication SystemGUID Platform GUID of the computer system generating the indication VariableNames V
Table HP_DeviceIndication: Physical Drive status ERROR Property name Property implementation CIM_Indication IndicationIdentifier GUID string generated at the time of indication PreceivedSeverity Severity For example, 5 (Major) IndicationTime Time of indication CIM_AlertIndication Description A physical drive status has changed to Error.
Table HP_DeviceIndication: Physical Drive status ERROR Property name Property implementation VariableNames FailureDescription VariableTypes 1 (String) VariableValues Short Description of failure In some cases, the property VariableValues can have N/A or “” values. ImpactedDomain 3 (Enclosure) for c-Class blade systems 4 (System) for all other systems When ImpactedDomain is 3 (Enclosure), the properties indicated with (*) are populated. BladeBay * HP_BladeCSLocation.
Table HP_DeviceIndication: Physical Drive status REBUILDING Property name Property implementation AlertingElementFormat 2 (CIMObjectPath) AlertType 5 (Device Alert) EventID 203 EventTime Time of the event or time of the indication if event time unknown ProviderName HP SAS RecommendedActions No action is recommended.
Table HP_DeviceIndication: Physical Drive status REBUILDING Property name Property implementation BladeName * HP_ComputerSystem.Name EnclosureName * HP_BladeEnclosureCS.
Table HP_DeviceIndication: Drive status PREDICTIVE FAILURE Property name Property implementation HP_AlertIndication Summary Physical drive predictive failure EventCategory 6 (Primary Storage) ProbableCause 86 (Disk Failure) ProbableCauseDescription Physical Drive Predictive Failure ProviderVersion Provider version generating the indication in the format, ...
Table HP_DeviceIndication: Drive status PREDICTIVE FAILURE Property name Property implementation HWFirmwareVersion Disk firmware version string HWLogicalLocation Disk Location string For example, Bay 3 HWManufacturer Disk Manufacturer string HWSerialNumber Disk Serial Number HP_DeviceIndication DeviceModel Disk Model string 1-2-7 Logical Drive status OK Table HP_DeviceIndication: Logical Drive status OK Property name Property implementation CIM_Indication IndicationIdentifier GUID string gene
Table HP_DeviceIndication: Logical Drive status OK Property name Property implementation OSType On ESXi, 39 (VM) On Linux, 36 (Linux) OSVersion The operating system version of the computer system generating the indication in the following format: ..
Table HP_DeviceIndication: Logical Drive status ERROR Property name Property implementation AlertType 5 (Device Alert) EventID 102 EventTime Time of the event or time of the indication if event time unknown ProviderName HP SAS RecommendedActions Check for failed or removed physical drives.
Table HP_DeviceIndication: Logical Drive status ERROR Property name Property implementation SystemVirtualSerialNumber Conditional property containing the virtual system serial number string when running in a Virtual Connect environment SystemVirtualUUID Conditional property containing the virtual system UUID when running in a Virtual Connect environment 1-2-9 Logical Drive status Degraded Table HP_DeviceIndication: Logical Drive is in a degraded state Property name Property implementation CIM_Indic
Table HP_DeviceIndication: Logical Drive is in a degraded state Property name Property implementation OSVersion The operating system version of the computer system generating the indication in the following format: ..
Table HP_DeviceIndication: Enclosure Power Supply status changed to Non Redundant Property name Property implementation AlertType 5 (Device Alert) EventID 301 EventTime Time of the event or time of the indication if event time unknown ProviderName HP SAS RecommendedActions Check status of all enclosure power supplies. Ensure that power supplies have not failed. Add or replace power supplies as necessary.
Table HP_DeviceIndication: Enclosure Power Supply status changed to Non Redundant Property name Property implementation BladeBay * HP_BladeCSLocation.LocationInformation[0] BladeName * HP_ComputerSystem.Name EnclosureName * HP_BladeEnclosureCS.
Table HP_DeviceIndication: Enclosure Power Supply status changed to OK (Redundant) Property name Property implementation SystemCreationClassName CreationClassName of the computer system generating the indication HP_AlertIndication Summary Redundant power supply status OK EventCategory 17 (Primary Storage Power) ProbableCause 1 (Other) ProbableCauseDescription Redundant Power Supply Status Changed to OK ProviderVersion Provider version generating the indication in the format, ..
Table HP_DeviceIndication: Enclosure Power Supply status changed to OK (Redundant) Property name Property implementation SystemVirtualUUID Conditional property containing the virtual system UUID when running in a Virtual Connect environment HP_HardwareIndication HWLogicalLocation Enclosure Location string For example, Port 1I Box 1 HWSerialNumber Enclosure Serial Number HP_DeviceIndication DeviceModel Enclosure Model string 1-2-12 Enclosure Power Supply Status changed to Redundant Degraded Table
Table HP_DeviceIndication: Enclosure Power Supply status changed to Redundant Degraded Property name Property implementation ProviderVersion Provider version generating the indication in the format, ...
1-2-13 Enclosure Temperature sensor Status changed to OK Table HP_DeviceIndication: Enclosure Temperature sensor status changed to OK Property name Property implementation CIM_Indication IndicationIdentifier GUID string generated at the time of indication PerceivedSeverity 2 (Info) IndicationTime Time of indication CIM_AlertIndication Description A Storage Enclosure Temperature sensor Status changed from non-OK to OK.
Table HP_DeviceIndication: Enclosure Temperature sensor status changed to OK Property name Property implementation SystemModel Model name of the computer system generating the indication SystemGUID Platform GUID of the computer system generating the indication VariableNames FailureDescription VariableTypes 1 (String) VariableValues Short Description of failure In some cases, the property VariableValues can have N/A or “” values.
Table HP_DeviceIndication: Enclosure Temperature sensor status changed to Warning Property name Property implementation Description A Storage Enclosure Temperature sensor Status changed to Warning Condition. This indicates the enclosure temperature is above normal, otherwise enclosure is still operating normally.
Table HP_DeviceIndication: Enclosure Temperature sensor status changed to Warning Property name Property implementation VariableValues Short Description of failure In some cases, the property VariableValues can have N/A or “” values. ImpactedDomain 3 (Enclosure) for c-Class blade systems 4 (System) for all other systems When ImpactedDomain is 3 (Enclosure), the properties indicated with (*) are populated. BladeBay * HP_BladeCSLocation.LocationInformation[0] BladeName * HP_ComputerSystem.
Table HP_DeviceIndication: Enclosure Temperature sensor status changed to Critical Property name Property implementation AlertType 5 (Device Alert) EventID 309 EventTime Time of the event or time of the indication if event time unknown ProviderName HP SAS RecommendedActions Ensure that the system is adequately ventilated. Check for proper room temperature and internal/external airflow. Add or repair fans and air baffling if necessary.
Table HP_DeviceIndication: Enclosure Temperature sensor status changed to Critical Property name Property implementation BladeBay * HP_BladeCSLocation.LocationInformation[0] BladeName * HP_ComputerSystem.Name EnclosureName * HP_BladeEnclosureCS.
Table HP_DeviceIndication: Enclosure Fan status changed to OK Property name Property implementation Summary Fan status OK EventCategory 24 (Primary Storage Cooling) ProbableCause 1 (Other) ProbableCauseDescription Fan Status Changed to OK NetworkAddresses Contains a list of all the IP addresses (IPv4 and IPv6) of the computer system generating the indication OSType On ESXi, 39(VM) On Linux, 36 (Linux) OSVersion The operating system version of the computer system generating the indication
Table HP_DeviceIndication: Enclosure Fan status changed to OK Property name Property implementation HWLogicalLocation Enclosure Location string For example, Port 1I Box 1 HWSerialNumber Enclosure Serial Number HP_DeviceIndication DeviceModel 1-2-17 Enclosure Model string Enclosure Fan status changed to Degraded Table HP_DeviceIndication: Enclosure Fan status changed to Degraded Property name Property implementation CIM_Indication IndicationIdentifier GUID string generated at the time of indicati
Table HP_DeviceIndication: Enclosure Fan status changed to Degraded Property name Property implementation OSType On ESXi, 39(VM) On Linux, 36 (Linux) OSVersion The operating system version of the computer system generating the indication in the format: ..
Table HP_DeviceIndication: Enclosure Fan status changed to Failure Property name Property implementation CIM_Indication IndicationIdentifier GUID string generated at the time of indication PerceivedSeverity 5 (major) IndicationTime Time of indication CIM_AlertIndication Description A Storage Enclosure Fan Status changed to Failure. An enclosure has detected a failure in the fan subsystem and there is insufficient fan capability to ensure normal operation.
Table HP_DeviceIndication: Enclosure Fan status changed to Failure Property name Property implementation SystemModel Model name of the computer system generating the indication SystemGUID Platform GUID of the computer system generating the indication VariableNames FailureDescription VariableTypes 1 (String) VariableValues Short Description of failure In some cases, the property VariableValues can have N/A or “” values.
HP Insight Management SAS HBA Provider The following chapters define the supported properties for the SAS HBA provider. For details of each property, see the HP SAS HBA profile (P00122) and associated MOF file. 1-2-19 SMX_SASArraySystem SMX_SASArraySystem represents the top level system. There is one instance per HBA.
Table Class: SMX_SASArrayController (CIM_ComputerSystem) Property name Property implementation ElementName Controller name and location For example, HP 8 INT Port SAS/SATA HBA in Slot 3 CIM_ManagedSystemElement OperationalStatus[0] Status for Array Controller 0 (Unknown) 2 (OK) 6 (Error) CIM_LogicalElement CIM_EnabledLogicalElement EnabledDefault 2 (Enabled) EnabledState 5 (Not Applicable) RequestedState 12 (Not Applicable) CIM_System CreationClassName SMX_SASArrayController Name Contro
Table Class: SMX_SASStorageVolume (CIM_StorageVolume) Property name Property implementation CIM_LogicalDevice CreationClassName SMX_SASStorageVolume DeviceID Opaque Key SystemCreationClassName SMX_SASArraySystem SystemName SMX_SASArraySystem.Name CIM_StorageExtent ConsumableBlocks Total Number of blocks on the volume.
Table Class: SMX_SASDiskDrive (CIM_DiskDrive) Property name Property implementation CIM_ManagedElement ElementName Disk location For example, Port 1E Box 1 Bay 2 CIM_ManagedSystemElement Name SAS Address OperationalStatus[0] Operational Status for the disk drive 0 (Unknown) 2 (OK) 5 (Predictive Failure) 6 (Error) CIM_LogicalElement CIM_EnabledLogicalElement EnabledDefault 2 (Enabled) EnabledState 5 (Not Applicable) RequestedState 12 (Not Applicable) CIM_LogicalDevice CreationClassNam
Table Class: SMX_SASStorageExtent (CIM_StorageExtent) Property name Property implementation CIM_ManagedElement ElementName Disk location For example, Port 1E Box 1 Bay 2 CIM_ManagedSystemElement Name Serial number of drive OperationalStatus[0] Operational Status for the disk drive 0 (Unknown) 2 (OK) 5 (Predictive Failure) 6 (Error) CIM_LogicalElement CIM_EnabledLogicalElement EnabledDefault 2 (Enabled) EnabledState 5 (Not Applicable) RequestedState 12 (Not Applicable) CIM_LogicalDevic
Table Class: SMX_SASDiskDriveFirmware (CIM_SoftwareIdentity) Property name Property implementation ElementName TargetType value CIM_ManagedSystemElement Name Disk Drive Firmware CIM_LogicalElement Caption Disk Drive Firmware Description Disk Drive Firmware CIM_SoftwareIdentity ClassificationDescriptions[0] Disk Drive Firmware Classifications[0] 10 (Firmware) InstanceID Opaque key Manufacturer Disk drive vendor string IdentityInfoType [0]CIM:SoftwareFamily [1]HPQ:SoftwareCategory Identity
Table Class: SMX_SASPhysicalPackage (CIM_PhysicalPackage) Property name Property implementation RemovalConditions 2 (Not Applicable) SMX_SASPhysicalPackage 1-2-26 SMX_SASDiskPhysicalPackage SMX_SASDiskPhysicalPackage represents the physical aspects of the disk drive. There is one instance per disk drive.
Table Class: SMX_SASPortController (CIM_PortController) Property name Property implementation CIM_ManagedElement ElementName Controller name and location, for example, HP 8 INT Port SAS/SATA HBA in Slot 3 CIM_ManagedSystemElement CIM_LogicalElement CIM_EnabledLogicalElement EnabledDefault 2 (Enabled) EnabledState 5 (Not Applicable) RequestedState 12 (Not Applicable) CIM_LogicalDevice CreationClassName SMX_SASPortController DeviceID Controller serial number SystemCreationClassName SMX_SASArray
Table Class: SMX_SASDAPort (CIM_DAPort) Property name Property implementation EnabledState 5 (Not Applicable) RequestedState 12 (Not Applicable) CIM_LogicalDevice CreationClassName SMX_SASDAPort DeviceID Opaque key SystemCreationClassName SMX_SASArraySystem SystemName SMX_SASArraySystem.Name CIM_LogicalPort UsageRestriction 2 (Front-End Only) CIM_DAPort PortType 82 (PCI) SMX_SASDAPort 1-2-29 SMX_SASFirmware SMX_SASFirmware represents the firmware installed on a SAS HBA controller.
Table Class: SMX_SASFirmware (CIM_SoftwareIdentity) Property name Property implementation SMX_SASFirmware 1-2-30 SMX_SASPrimordialPool SMX_SASPrimordialPool represents the total raw storage managed by the array controller that is assigned to Raid volumes. Table Class: SMX_SASPrimordialPool (CIM_StoragePool) Property name Property implementation CIM_ManagedElement ElementName Controller name and location: pool identifier.
Table Class: SMX_SASPrimordialPoolNoRaid (CIM_StoragePool) Property name Property implementation Primordial TRUE RemainingManagedSpace 0 TotalManagedSpace Total raw space available to controller. This is calculated by summing the total space on all non raid drives connected to this controller. SMX_SASPrimordialPoolNoRaid 1-2-32 SMX_SASStoragePool SMX_SASStoragePool represents any concrete storage pools created on an array controller. There is one instance per HBA for this implementation.
Table Class: SMX_SASStorageSetting (CIM_StorageSetting) Property name Property implementation InstanceID Opaque key CIM_StorageSetting ChangeableType 0 (Not Changeable) DataRedundancyGoal 1 (RAID 0) 2 (RAID 1) DataRedundancyMax 1 (RAID 0) 2 (RAID 1) DataRedundancyMin 1 (RAID 0) 2 (RAID 1) DeltaReservationGoal 0 DeltaReservationMax 0 DeltaReservationMin 0 NoSinglePointOfFailure FALSE—RAID 0 TRUE—RAID 1 PackageRedundancyGoal 0 (RAID 0) 1 (RAID 1) PackageRedundancyMax
Table Class: SMX_SASSCSIProtocolEndpoint (CIM_SCSIProtocolEndpoint) Property name Property implementation SystemCreationClassName SMX_SASArraySystem SystemName SMX_SASArraySystem.Name CIM_ProtocolEndpoint ProtocolIFType 0 (Unknown) CIM_SCSIProtocolEndpoint ConnectionType 1 (Other) OtherConnectionType PCI Role 4 (Both Initiator and Target) SMX_SASSCSIProtocolEndpoint 1-2-35 SMX_SASSCSIProtocolController SMX_SASSCSIProtocolController represents a view a SCSI resources on the controller.
1-2-36 SMX_SASStorageRedundancySet SMX_SASStorageRedundancySet represents disk sparing aspect of a RAID configuration. There is an instance for every raid set that has spare drives configured.
1-2-38 SMX_SASArraySystemLocation SMX_SASArraySystemLocation represents a location string for the HBA.
Table Class: SMX_SASDiskDriveLocation (HP_Location) Property name Property implementation HP_Location ElementLocationTag Bay Number or SCSI ID of Disk ElementLocationTagDesc 20 (Bay) or 21 (SCSI ID) SMX_SASDiskDriveLocation 1-2-40 SMX_SASStorageCapabilities SMX_SASStorageCapabilities represents the possible capabilities of a Storage Pool.
Table Class: SMX_SASStorageCapabilities (CIM_StorageCapabilities) Property name Property implementation PackageRedundancyDefault 0 (When Pool is NonRAID) 1 (When number of drives = 1) 2 (When number of drives > 1) PackageRedundancyMax 0 (When Pool is NonRAID) 1 (When number of drives = 1) 2 (When number of drives > 1) PackageRedundancyMin 0 SMX_SASStorageCapabilities 1-2-41 SMX_SASProduct SMX_SASProduct represents the marketing information for the HBA.
Table Class: SMX_SASDriveCage (CIM_PhysicalPackage) Property name Property implementation Manufacturer Drive Cage Vendor string Model Drive Cage Model string PartNumber N/A–Not available in this implementation Tag Opaque key SerialNumber Enclosure Serial number Version N/A–Not available in this implementation CIM_PhysicalPackage RemovalConditions 2 (Not Applicable) HP_DriveCage BackplaneSpeed See profile DriveBays See profile DuplexLocation See profile SMX_SASDriveCage 1-2-43 SMX_SASEn
1-2-44 SMX_SASStorageEnclosure SMX_SASStorageEnclosure represents the physical chassis for an internal or externally attached enclosure.
Table Class: SMX_SASStorageEnclosureProcessor (CIM_ComputerSystem) Property name Property implementation ElementName Port: Box: , where is the port and is the box number CIM_ManagedSystemElement OperationalStatus[0,1, 2, 3 ] Operational status for enclosure and associated power supplies, fans, and sensors. The use of OperationalStatus is described in the HP Storage Enclosure Profile.
Table Class: HPAS_StorageEnclosureLocation (HP_Location) Property name Property implementation Description Enclosure location For example, Port 1E Box 1 Name Key PhysicalPosition Key ElementLocationTag Unknown for Undetermined External for external enclosures Internal for drive cages located within the host chassis ElementLocationTagDesc 19 (Box) 1-2-47 SMX_SASDriveCageDiskPhysicalPackage (Association) Table Class: SMX_SASDriveCageDiskPhysicalPackage (CIM_Container) Property name Proper
Table Class: SMX_SASArraySystemStorageEnclosureProcessor (CIM_SystemComponent) Property name Property implementation PartComponent SMX_SASStorageEnclosureProcessor 1-2-51 SMX_SASStorageEnclosureProcessorEnclosureFirmwar e (Association) Table Class: SMX_SASStorageEnclosureProcessorEnclosureFirmware (CIM_ElementSoftwareIdentity) Property name Property implementation Antecedent SMX_SASEnclosureFirmware Dependent SMX_SASStorageEnclosureProcessor ElementSoftwareStatus ElementSoftwareStatus[0]: 2 (C
1-2-55 SMX_SASPrimordialPoolNoRaidStorageCapabilities (Association) Table Class: SMX_SASPrimordialPoolNoRaidStorageCapabilities (CIM_ElementCapabilities) Property name Property implementation Capabilities SMX_SASStorageCapabilities ManagedElement SMX_SASPrimordialPoolNoRaid 1-2-56 SMX_SASStoragePoolStorageCapabilities (Association) Table Class: SMX_SASStoragePoolStorageCapabilities (CIM_ElementCapabilities ) Property name Property implementation Capabilities SMX_SASStorageCapabilities ManagedElem
Table Class: SMX_SASArraySystemStorageVolume (CIM_SystemDevice) Property name Property implementation GroupComponent SMX_SASArraySystem PartComponent SMX_SASStorageVolume 1-2-61 SMX_SASArraySystemStorageExtent (Association) Table Class: SMX_SASArraySystemStorageExtent (CIM_SystemDevice) Property name Property implementation GroupComponent SMX_SASArraySystem PartComponent SMX_SASStorageExtent 1-2-62 SMX_SASArraySystemDAPort (Association) Table Class: SMX_SASArraySystemDAPort (CIM_SystemDevice
Table Class: SMX_SASArraySystemStoragePool (CIM_HostedStoragePool) Property name Property implementation GroupComponent SMX_SASArraySystem PartComponent SMX_SASStoragePool 1-2-66 SMX_SASComputerSystemArraySystem (Association) Table Class: SMX_SASComputerSystemArraySystem (CIM_ComponentCS) Property name Property implementation GroupComponent HP_ComputerSystem PartComponent SMX_SASArraySystem 1-2-67 SMX_SASArraySystemArrayController (Association) Table Class: SMX_SASArraySystemArrayController (C
1-2-71 SMX_SASPrimordialPoolNoRaidStorageExtent (Association) Table Class: SMX_SASPrimordialPoolNoRaidStorageExtent (CIM_ConcreteComponent) Property name Property implementation GroupComponent SMX_SASPrimordialPoolNoRaid PartComponent SMX_SASStorageExtent 1-2-72 SMX_SASStorageSpecificCollectionArraySystem (Association) Table Class: SMX_SASStorageSpecificCollectionArraySystem (CIM_MemberOfCollection) Property name Property implementation Collection SMX_SASStorageSpecificCollection Member SMX_SAS
Table Class: SMX_SASSCSIProtocolControllerStorageVolume (CIM_ProtocolControllerForUnit) Property name Property implementation DeviceAccess 2 (Read Write) 1-2-76 SMX_SASFirmwareArraySystem (Association) Table Class: SMX_SASFirmwareArraySystem (CIM_ElementSoftwareIdentity) Property name Property implementation Antecedent SMX_SASFirmware Dependent SMX_SASArraySystem ElementSoftwareStatus ElementSoftwareStatus[0]: 2 (Current) ElementSoftwareStatus[1]: 6 (Installed) 1-2-77 SMX_SASDiskDriveDiskDri
Table Class: SMX_SASPrimordialPoolStoragePool (CIM_AllocatedFromStoragePool) Property name Property implementation Antecedent SMX_SASPrimordialPool Dependent SMX_SASStoragePool SpaceConsumed Bytes consumed by storage pool 1-2-81 SMX_SASSpareExtentStorageRedundancySet (Association) Table Class: SMX_SASSpareExtentStorageRedundancySet (CIM_IsSpare) Property name Property implementation Antecedent SMX_SASStorageExtent Dependent SMX_SASStorageRedundancySet 1-2-82 SMX_SASStorageExtentStorageVolume
Table Class: SMX_SASPhysicalPackageArraySystem (CIM_ComputerSystemPackage) Property name Property implementation Antecedent SMX_SASPhysicalPackage Dependent SMX_SASArraySystem 1-2-86 SMX_SASPhysicalPackageArraySystemLocation (Association) Table Class: SMX_SASPhysicalPackageArraySystemLocation (CIM_PhysicalElementLocation) Property name Property implementation Element SMX_SASPhysicalPackage Physical Location SMX_SASArraySystemLocation 1-2-87 SMX_SASDiskPhysicalPackageDiskDriveLocation (Associat
Table HP_DeviceIndication: SAS HBA status OK Property name Property implementation CIM_AlertIndication Description A SAS/SATA HBA status has changed from non-OK to OK. AlertingManagedElement WBEM Path of controller AlertingElementFormat 2 (CIMObjectPath) AlertType 5 (Device Alert) EventID 1 EventTime Time of the event or time of the indication if event time unknown ProviderName HP SAS RecommendedActions No action is recommended.
Table HP_DeviceIndication: SAS HBA status OK Property name Property implementation BladeName * HP_ComputerSystem.Name EnclosureName * HP_BladeEnclosureCS.
Table HP_DeviceIndication: SAS HBA in Error state Property name Property implementation SystemCreationClassName CreationClassName of the computer system generating the indication HP_AlertIndication Summary HBA status Error EventCategory 11 (I/O Adapter) ProbableCause 2 (Adapter/Card Error) ProbableCauseDescription HBA Status Changed to Error ProviderVersion Provider version generating the indication in the format, ...
Table HP_DeviceIndication: SAS HBA in Error state Property name Property implementation HWManufacturer Controller Manufacturer string HWSerialNumber Controller Serial Number HP_DeviceIndication DeviceModel Controller Model string 1-3-3 Physical Drive Status OK Table HP_DeviceIndication: Physical Drive status OK Property name Property implementation CIM_Indication IndicationIdentifier GUID string generated at the time of indication PreceivedSeverity 2 (Informational) IndicationTime Time of ind
Table HP_DeviceIndication: Physical Drive status OK Property name Property implementation SystemFirmwareVersion Firmware version of the computer system generating the indication SystemSerialNumber Serial number of the computer system generating the indication SystemProductID Product ID of the computer system generating the indication SystemModel Model name of the computer system generating the indication SystemGUID Platform GUID of the computer system generating the indication VariableNames V
Table HP_DeviceIndication: Physical Drive status ERROR Property name Property implementation CIM_Indication IndicationIdentifier GUID string generated at the time of indication PreceivedSeverity Severity For example, 5 (Major) IndicationTime Time of indication CIM_AlertIndication Description A physical drive status has changed to Error.
Table HP_DeviceIndication: Physical Drive status ERROR Property name Property implementation VariableNames FailureDescription VariableTypes 1 (String) VariableValues Short Description of failure In some cases, the property VariableValues can have N/A or “” values. ImpactedDomain 3 (Enclosure) for c-Class blade systems 4 (System) for all other systems When ImpactedDomain is 3 (Enclosure), the properties indicated with (*) are populated. BladeBay * HP_BladeCSLocation.
Table HP_DeviceIndication: Physical Drive status REBUILDING Property name Property implementation AlertingElementFormat 2 (CIMObjectPath) AlertType 5 (Device Alert) EventID 203 EventTime Time of the event or time of the indication if event time unknown ProviderName HP SAS RecommendedActions No action is recommended.
Table HP_DeviceIndication: Physical Drive status REBUILDING Property name Property implementation BladeName * HP_ComputerSystem.Name EnclosureName * HP_BladeEnclosureCS.
Table HP_DeviceIndication: Drive status PREDICTIVE FAILURE Property name Property implementation HP_AlertIndication Summary Physical drive predictive failure EventCategory 6 (Primary Storage) ProbableCause 86 (Disk Failure) ProbableCauseDescription Physical Drive Predictive Failure ProviderVersion Provider version generating the indication in the format, ...
Table HP_DeviceIndication: Drive status PREDICTIVE FAILURE Property name Property implementation HWFirmwareVersion Disk firmware version string HWLogicalLocation Disk Location string For example, Bay 3 HWManufacturer Disk Manufacturer string HWSerialNumber Disk Serial Number HP_DeviceIndication DeviceModel Disk Model string 1-3-7 Logical Drive status OK Table HP_DeviceIndication: Logical Drive status OK Property name Property implementation CIM_Indication IndicationIdentifier GUID string gene
Table HP_DeviceIndication: Logical Drive status OK Property name Property implementation OSType On ESXi, 39 (VM) On Linux, 36 (Linux) OSVersion The operating system version of the computer system generating the indication in the following format: ..
Table HP_DeviceIndication: Logical Drive status ERROR Property name Property implementation AlertType 5 (Device Alert) EventID 102 EventTime Time of the event or time of the indication if event time unknown ProviderName HP SAS RecommendedActions Check for failed or removed physical drives.
Table HP_DeviceIndication: Logical Drive status ERROR Property name Property implementation SystemVirtualSerialNumber Conditional property containing the virtual system serial number string when running in a Virtual Connect environment SystemVirtualUUID Conditional property containing the virtual system UUID when running in a Virtual Connect environment 1-3-9 Logical Drive status Degraded Table HP_DeviceIndication: Logical Drive is in a degraded state Property name Property implementation CIM_Indic
Table HP_DeviceIndication: Logical Drive is in a degraded state Property name Property implementation OSVersion The operating system version of the computer system generating the indication in the following format: ..
Table HP_DeviceIndication: Enclosure Power Supply status changed to Non Redundant Property name Property implementation AlertType 5 (Device Alert) EventID 301 EventTime Time of the event or time of the indication if event time unknown ProviderName HP SAS RecommendedActions Check status of all enclosure power supplies. Ensure that power supplies have not failed. Add or replace power supplies as necessary.
Table HP_DeviceIndication: Enclosure Power Supply status changed to Non Redundant Property name Property implementation BladeBay * HP_BladeCSLocation.LocationInformation[0] BladeName * HP_ComputerSystem.Name EnclosureName * HP_BladeEnclosureCS.
Table HP_DeviceIndication: Enclosure Power Supply status changed to OK (Redundant) Property name Property implementation SystemCreationClassName CreationClassName of the computer system generating the indication HP_AlertIndication Summary Redundant power supply status OK EventCategory 17 (Primary Storage Power) ProbableCause 1 (Other) ProbableCauseDescription Redundant Power Supply Status Changed to OK ProviderVersion Provider version generating the indication in the format, ..
Table HP_DeviceIndication: Enclosure Power Supply status changed to OK (Redundant) Property name Property implementation SystemVirtualUUID Conditional property containing the virtual system UUID when running in a Virtual Connect environment HP_HardwareIndication HWLogicalLocation Enclosure Location string For example, Port 1I Box 1 HWSerialNumber Enclosure Serial Number HP_DeviceIndication DeviceModel Enclosure Model string 1-3-12 Enclosure Power Supply Status changed to Redundant Degraded Table
Table HP_DeviceIndication: Enclosure Power Supply status changed to Redundant Degraded Property name Property implementation ProviderVersion Provider version generating the indication in the format, ...
1-3-13 Enclosure Temperature sensor Status changed to OK Table HP_DeviceIndication: Enclosure Temperature sensor status changed to OK Property name Property implementation CIM_Indication IndicationIdentifier GUID string generated at the time of indication PerceivedSeverity 2 (Info) IndicationTime Time of indication CIM_AlertIndication Description A Storage Enclosure Temperature sensor Status changed from non-OK to OK.
Table HP_DeviceIndication: Enclosure Temperature sensor status changed to OK Property name Property implementation SystemModel Model name of the computer system generating the indication SystemGUID Platform GUID of the computer system generating the indication VariableNames FailureDescription VariableTypes 1 (String) VariableValues Short Description of failure In some cases, the property VariableValues can have N/A or “” values.
Table HP_DeviceIndication: Enclosure Temperature sensor status changed to Warning Property name Property implementation Description A Storage Enclosure Temperature sensor Status changed to Warning Condition. This indicates the enclosure temperature is above normal, otherwise enclosure is still operating normally.
Table HP_DeviceIndication: Enclosure Temperature sensor status changed to Warning Property name Property implementation VariableValues Short Description of failure In some cases, the property VariableValues can have N/A or “” values. ImpactedDomain 3 (Enclosure) for c-Class blade systems 4 (System) for all other systems When ImpactedDomain is 3 (Enclosure), the properties indicated with (*) are populated. BladeBay * HP_BladeCSLocation.LocationInformation[0] BladeName * HP_ComputerSystem.
Table HP_DeviceIndication: Enclosure Temperature sensor status changed to Critical Property name Property implementation AlertType 5 (Device Alert) EventID 309 EventTime Time of the event or time of the indication if event time unknown ProviderName HP SAS RecommendedActions Ensure that the system is adequately ventilated. Check for proper room temperature and internal/external airflow. Add or repair fans and air baffling if necessary.
Table HP_DeviceIndication: Enclosure Temperature sensor status changed to Critical Property name Property implementation BladeBay * HP_BladeCSLocation.LocationInformation[0] BladeName * HP_ComputerSystem.Name EnclosureName * HP_BladeEnclosureCS.
Table HP_DeviceIndication: Enclosure Fan status changed to OK Property name Property implementation Summary Fan status OK EventCategory 24 (Primary Storage Cooling) ProbableCause 1 (Other) ProbableCauseDescription Fan Status Changed to OK NetworkAddresses Contains a list of all the IP addresses (IPv4 and IPv6) of the computer system generating the indication OSType On ESXi, 39(VM) On Linux, 36 (Linux) OSVersion The operating system version of the computer system generating the indication
Table HP_DeviceIndication: Enclosure Fan status changed to OK Property name Property implementation HWLogicalLocation Enclosure Location string For example, Port 1I Box 1 HWSerialNumber Enclosure Serial Number HP_DeviceIndication DeviceModel 1-3-17 Enclosure Model string Enclosure Fan status changed to Degraded Table HP_DeviceIndication: Enclosure Fan status changed to Degraded Property name Property implementation CIM_Indication IndicationIdentifier GUID string generated at the time of indicati
Table HP_DeviceIndication: Enclosure Fan status changed to Degraded Property name Property implementation OSType On ESXi, 39(VM) On Linux, 36 (Linux) OSVersion The operating system version of the computer system generating the indication in the format: ..
Table HP_DeviceIndication: Enclosure Fan status changed to Failure Property name Property implementation CIM_Indication IndicationIdentifier GUID string generated at the time of indication PerceivedSeverity 5 (major) IndicationTime Time of indication CIM_AlertIndication Description A Storage Enclosure Fan Status changed to Failure. An enclosure has detected a failure in the fan subsystem and there is insufficient fan capability to ensure normal operation.
Table HP_DeviceIndication: Enclosure Fan status changed to Failure Property name Property implementation SystemModel Model name of the computer system generating the indication SystemGUID Platform GUID of the computer system generating the indication VariableNames FailureDescription VariableTypes 1 (String) VariableValues Short Description of failure In some cases, the property VariableValues can have N/A or “” values.
HP Insight Management SAS HBA Provider 324
HP Insight Manager WBEM Smart Component Installer Provider Overview Description The HP Insight Management Web-Based Enterprise Management (WBEM) Smart Component Installer implements and extends CIM classes described in this document to support installation of HP SmartComponents. This provider supports the InstallFromURI() method with the http URI scheme to retrieve and install HP Smart Components. Profile Name Organization Version DMTF Software Update Profile (DSP 1025) DMTF 1.0.
The tables in the following sections describe the properties of the supported classes. The classes are categorized by the class or superclass that defines the property, the first column is the Property Name (including type and units) and the second column describes how the provider determines the properties implementation. When the Property Implementation value is a number, the number given is the default behavior and the Managed Object Format interpretation is within parenthesis.
2-2-1-1 Implemented Methods for SMX_SCInstallationService Class Method Name InstallFromURI Method Implementation Must be root to request this method. Unless specified, the matching value in the InstallOptionValues[]for each InstallOptions[] is NULL or an empty string.
The following table lists the properties implemented.
Property Name Property Implementation 5: http SupportedURISchemes[] SMX_SCInstallationServiceCapabilities 2-2-3 SMX_SCInstallerHostedService Class The SMX_SCInstallerHostedService class implements the CIM_HostedService class and associates instances of SMX_ComputerSystem and SMX_SCInstallationService. There is only one instance of SMX_SCInstallerHostedService instantiated on a server. The following table lists the properties implemented.
Property Name Property Implementation executed Caption “Job for execution of HP Smart Component ” where is the name of the Smart Component being executed Description “Job for execution of HP Smart Component ” where is the name of the Smart Component being executed ElementName “Job for execution of HP Smart Component ” where is the name of the Smart Component being executed CIM_ManagedSystemElement CIM_LogicalElement Status Same as OperationalStatus[0].
GetDetailedStatus Get the detailed status of the last execution of the Smart Component. Method parameters: DetailedStatus[]: array of strings containing the contents of the detailed status output file from the SmartComponent Return Values: 0 : Successful 1 : Not Supported 4 : Failed GetDiscoveryData Get the discovery data from the last execution of the Smart Component.
Property Name Property Implementation CIM_HostedDependency CIM_HostedService Antecedent References SMX_SCInstallationService Dependent References SMX_SCInstallerConcreteJob SMX_SCInstallerJobHostedDependency 2-3 Supported Indications No Indications are supported in the SMX_SCInstallerService provider.
HP Insight Management WBEM System Temperature Sensor Provider Description The HP Insight Management Web-Based Enterprise Management (WBEM) Management System Temperature Sensor provider extends the management capability of referencing profiles by adding the capability to represent HP Management Processor on HP servers. This provider implements the following profiles and installs the necessary files: Profile Name Organization Version HP Sensor Profile HP WBEM TC 1.2.
SMX_NumericSensor Class The SMX_NumericSensor class implements the HP_NumericSensor and is used to model temperature sensors on servers. The following table lists the properties implemented. Property Name Property Implementation CIM_ManagedElement Caption “Temperature Sensor ” Where: is the name displayed by the MP or iLO. For example: Temperature Sensor Temp 1 Description “Temperature Sensor detects for NumericSensorType.
Property Name Name Property Implementation where n represents the number of the temperature sensor instance(s). Temperature Sensor n CIM_LogicalDevice CreationClassName SMX_NumericSensor DeviceID Unique identifier for this temperature sensor instance. SystemCreationClassName HP_ComputerSystem.CreationClassName SystemName HP_ComputerSystem.
Property Name Property Implementation gracefully attempt to shutdown the system if the threshold is crossed. Contains the threshold temperature that CurrentReading must exceed to be fatal. This is only set if the system will immediately power down the system if the threshold is crossed. UpperThresholdFatal HP_NumericSensor Enumeration describing the type of temperature sensor. Refer to the Managed Object Format.
Property Name Property Implementation Temperatures reported by the sensors are operating within normal operating range if temperatures reported by the sensors are within normal operating range; Temperatures reported by the sensors have exceeded their non-critical threshold and the fans have been GroupStatusDescriptions[0] set to full speed if temperatures reported by the sensors have exceeded their threshold and has set fans to full speed; Temperatures reported by the sensors have exceeded their thresh
GroupComponent References SMX_ComputerSystem PartComponent References SMX_NumericSensor Provider Indications The following tables describe the SMX WBEM System Temperature Sensor Indications Generated Provider indications that are implemented for HP ProLiant server platforms by the Provider where available. HP_AlertIndication: Temperature Sensor Threshold Exceeded Property Name Property Implementation CIM_Indication IndicationIdentifier GUID string generated at the time of indication.
Property Name Property Implementation ProviderVersion For example: 2.2.0.0 NetworkAddresses Contains a list of all the IP addresses of the computer system generating the indication. OSType SMX_OperatingSystem.OSType OSVersion The operating system version of the computer system generating the indication in the following format: major.minor.build SystemFirmwareVersion Firmware version of the computer system generating the indication.
HP_AlertIndication: Temperature Sensor Recovery from Threshold Exceeded Property Name Property Implementation CIM_Indication IndicationIdentifier GUID string generated at the time of indication. PerceivedSeverity 2 IndicationTime Time of indication. (Information) CIM_AlertIndication A temperature sensor has detected that the temperature has returned to a normal operating range. Description Where: is the SMX_NumericSensor.
Property Name Property Implementation SystemModel Model name of the computer system generating the indication. SystemGUID Platform GUID of the computer system generating the indication. ImpactedDomain (Enclosure) for c-Class blade systems (System) for all other systems Note: When ImpactedDomain is 3 (Enclosure) the properties indicated with (*) below will be populated. BladeBay * HP_BladeCSLocation.LocationInformation[0] BladeName * HP_ComputerSystem.Name EnclosureName * HP_BladeEnclosureCS.
HP Insight Management WBEM Smart Array Provider The HP Insight Management Web-Based Enterprise Management (WBEM) Management Smart Array provider extends the management capability of referencing profiles by adding the capability to represent HP Management Processor on HP servers. This provider only supports internal storage and direct attached external storage, such as MSA 60/70.
Schema Supported by the Provider This provider supports the following classes: SMX_SAArraySystem SMX_SAArrayController SMX_SAStorageVolume SMX_SADiskDrive SMX_SAStorageExtent SMX_SADiskDriveFirmware SMX_SAPhysicalPackage SMX_SAArrayControllerPhysicalPackage SMX_SADiskPhysicalPackage SMX_SAStorageEnclosure SMX_SAStorageEnclosureProcessor SMX_SAPortController SMX_SADAPort SMX_SAFirmware SMX_SAEnclosureFirmware S
SMX_SAStorageEnclosureDriveCage (Association) SMX_SAPhysicalPackageArrayControllerPhysicalPackage (Association) SMX_SAPhysicalPackageDiskPhysicalPackage (Association) SMX_SAPhysicalPackageStorageEnclosure (Association) SMX_SADriveCageDiskPhysicalPackage (Association) SMX_SAStoragePoolStorageExtent (Association) SMX_SAStorageSpecificCollectionArraySystem (Association) SMX_SAStorageRedundancySetStorageExtent (Associatio
Unless otherwise noted, all of the property implementation values given are for HP ProLiant and HP Integrity (cellular and non-cellular) systems. The location related properties and implementation values are determined based on the server type so they may differ. SMX_SAArraySystem Class The SMX_SAArraySystem class implements the HPSA_ArraySystem class and represents the top-level system. There is one instance per HBA. The following table lists the properties implemented.
Property Name Property Implementation CIM_System CreationClassName SMX_SAArraySystem Name Controller Serial Number EMBEDDED- will be reported if there is no Serial Number for device is local For example: embedded on motherboard. PCISLOT- will be reported if there is no Serial Number for device is local For example: PCI occupies slot.
Property Name ElementName Property Implementation Controller name and . Refer to “Physical Location” for more information. For example: “Smart Array in Slot=3” for internal For example: “Smart Array Embedded Controller=7” for embedded controller where 7 is the internal identifier for the embedded controller. CIM_ManagedSystemElement OperationalStatus[0] Status for Array Controller.
Property Name Property Implementation CacheParityReadErrors See HP Smart Array Profile CacheParityWriteErrors See HP Smart Array Profile CacheReadPercent See HP Smart Array Profile CacheSerialNumber See HP Smart Array Profile CacheSizeTotal See HP Smart Array Profile CacheState See HP Smart Array Profile CacheStatus See HP Smart Array Profile CacheWritePercent See HP Smart Array Profile ControllerStatus See HP Smart Array Profile ExpandPriority See HP Smart Array Profile NumberOfPorts
Property Name Property Implementation DeviceID Opaque Key SystemCreationClassName SMX_SAArraySystem SystemName SMX_SAArraySystem.Name CIM_StorageExtent ConsumableBlocks 0 BlockSize Block Size in bytes DataRedundancy 1 2 DeltaReservation 0 ExtentStatus[0] This will indicate extended status for the volume.
SMX_SADiskDrive Class The SMX_SADiskDrive class implements the HPSA_DiskDrive class and represents the hard drives connected to Smart Array controllers. The following table lists the properties implemented.
Property Name Identify() Property Implementation See HP Smart Array Profile SMX_SAStorageExtent Class The SMX_SAStorageExtent class implements the HPSA_StorageExtent class and represents the consumable storage that is available on a disk drive. There is one instance per disk drive. The following table lists the properties implemented.
Property Name Property Implementation ExtentStatus[0] This will indicate extended status for the disk drive Possible values: 2 (None) 11 (Rebuild – disk drive is currently rebuilding data) NumberOfBlocks Total number of blocks on disk drive Primordial Set to True TotalPowerOnHours Total service hours reported disk drive HPSA_StorageExtent SMX_SADiskDriveFirmware Class The SMX_SADiskDriveFirmware class implements the HPSA_DiskDriveFirmware class and represents the firmware installed on a disk drive
SMX_SAPhysicalPackage Class The SMX_SAPhysicalPackage class implements the HPSA_PhysicalPackage class and represents the overall physical package for the array system as a whole. There is one instance per HBA or Storage Subsystem. The following table lists the properties implemented. Property Name Property Implementation CIM_ManagedElement ElementName Controller/Storage System name and . Refer to “Physical Location” for more information.
ElementName Controller name and . Refer to “Physical Location” for more information. For example: “Smart Array in Slot=3” for internal For example: “Smart Array Embedded Controller=7” for embedded controller where 7 is the internal identifier for the embedded controller.
Property Name Property Implementation Manufacturer Drive vendor string Model Drive model string PartNumber N/A SerialNumber Drive serial number Tag Opaque Key Version N/A – Not Available in this implementation – Not Available in this implementation CIM_PhysicalPackage HotSwappable TRUE - Drive is hot swappable FALSE – Drive is not hot swappable (Not Applicable) 3 (Removable when off) 4 (Removable when on or off) 2 RemovalConditions HPSA_ DiskPhysicalPackage SMX_SAStorageEnclosure Class
The following table lists the properties implemented. Property Name Property Implementation CIM_ManagedElement ElementName Port: Box: Where: is the port and is the box number. CIM_ManagedSystemElement Name Port: Box: Where: is the port and is the box number.
Property Name Property Implementation CIM_ManagedElement Port: Box: Where: is the port and ElementName is the box number. CIM_ManagedSystemElement Operational status for enclosure and associated power supplies, fans and sensors. The use of OperationalStatus is described in the HP Storage Enclosure Profile. Index values are populated as follows.
SMX_SAPortController Class The SMX_SAPortController class represents the HBA in the host system. There is one instance per HBA. The following table lists the properties implemented. Property Name Property Implementation CIM_ManagedElement ElementName Controller name and . Refer to “Physical Location” for more information.
Property Name Property Implementation CIM_ManagedElement ElementName Controller name and . Refer to “Physical Location” for more information. For example: “Smart Array in Slot=3” for internal For example: “Smart Array Embedded Controller=7” for embedded controller where 7 is the internal identifier for the embedded controller.
Property Name Property Implementation CIM_ManagedSystemElement Name Array Controller Firmware CIM_LogicalElement Caption Array Controller Firmware Description Array Controller Firmware CIM_SoftwareIdentity ClassificationDescriptions[0] Array Controller Firmware (Firmware) Classifications[0] 10 InstanceID Opaque key Manufacturer Controller Vendor string IdentityInfoType [0]CIM:SoftwareFamily [1]HPQ:SoftwareCategory IdentityInfoValue [0]HPQ: [1]Storage Controller Versio
Property Name Property Implementation IdentityInfoType [0]CIM:SoftwareFamily [1]HPQ:SoftwareCategory IdentityInfoValue [0]HPQ: [1]StorageDevice VersionString Enclosure firmware string TargetTypes Enclosure model HPSA_EnclosureFirmware SMX_SAPrimordialPool Class The SMX_SAPrimordialPool class implements the HPSA_PrimordialPool class and represents the total raw storage managed by the array controller. There is one instance per array system.
SMX_SAStoragePool Class The SMX_SAStoragePool class implements the HPSA_StoragePool class and represents any concrete storage pools created on an array controller. There is one instance per array system. The following table lists the properties implemented. Property Name Property Implementation CIM_ManagedElement ElementName Controller name and . Refer to “Physical Location” for more information.
Property Name Property Implementation AbortedCommands See HP Smart Array Profile BadTargetErrors See HP Smart Array Profile DRQTimeouts See HP Smart Array Profile ECCRecoveredReadErrors See HP Smart Array Profile ElementName Disk location For example: Port: 1E Box 1 Bay: 5 FailedReadRecovers See HP Smart Array Profile FailedWriteRecovers See HP Smart Array Profile FormatErrors See HP Smart Array Profile HardReadErrors See HP Smart Array Profile HardwareErrors See HP Smart Array Profile
Property Name Property Implementation RAID Where: ElementName is the RAID Description.
SMX_SADriveCage Class The SMX_SADriveCage class implements the HPSA_DriveCage class and represents the drive cage assembly and back plane within a storage enclosure. There may be multiple instances within a duplexed enclosure.
The following table lists the properties implemented. Property Name Property Implementation CIM_ManagedElement ElementName Port Where: is For example: the name of the port this drive cage is connected.
Property Name ElementName Property Implementation Controller name and . Refer to “Physical Location” for more information. For example: “Smart Array in Slot=3” for internal For example: “Smart Array Embedded Controller=7” for embedded controller where 7 is the internal identifier for the embedded controller.
Property Name Property Implementation CIM_ManagedElement ElementName Controller name and . Refer to “Physical Location” for more information. For example: “Smart Array in Slot=3” for internal For example: “Smart Array Embedded Controller=7” for embedded controller where 7 is the internal identifier for the embedded controller.
Property Name Property Implementation ElementName Storage Redundancy Set CIM_Collection CIM_SystemSpecificCollection Opaque key InstanceID CIM_RedundancySet (No Load Balancing) LoadBalanceAlgorithm 2 MaxNumberSupported 0 MinNumberNeeded 0 RedundancyStatus 2 4 (Fully Redundant) (Redundancy Lost) TypeOfSet[0] 5 (Limited Sparing) CIM_StorageRedundancySet HPSA_StorageRedundancySet SMX_SAStorageSpecificCollection Class The SMX_SAStorageSpecificCollection class implements the HPSA_StorageSpec
SMX_SADriveCageLocation Class The SMX_SADriveCageLocation class implements the HPSA_DriveCageLocation class and represents a location string for the drive cage. The following table lists the properties implemented.
Property Name Property Implementation Name Opaque key PhysicalPosition Opaque key HP_Location ElementLocationTag PCI Slot Number – when ‘Adapter’ is specified in ElementLocationTagDesc 23 LocationInformation[0] Array of text values representing the location components that describe this Ethernet Controller Physical location. LocationInfoDesc[0] per LocationInfornation[0]. Refer to the LocationInfoDescription array to determine what type of location information is represented.
Property Name Property Implementation ElementLocationTagDesc. ElementLocationTagDesc 20 (Bay)– when firmware supports Bay numbering HPSA_DiskDriveLocation SMX_SAArrayControllerLocation Class The SMX_SAArrayControllerLocation class implements the HPSA_ArrayControllerLocation class and represents a location string for the array controller. The following table lists the properties implemented.
SMX_SAStorageCapabilities Class The SMX_SAStorageCapabilities class implements the HPSA_StorageCapabilities class and represents the possible Capabilities of a storage pool. The following table lists the properties implemented. Property Name Property Implementation CIM_ManagedElement ElementName For Primodial Pools: Controller name and . Refer to “Physical Location” for more information.
Property Name Property Implementation NoSinglePointOfFailureDefault - When number of drives > 1 (For example: Pool can be configured for redundancy) False – When number of drives <= 1 PackageRedundancyDefault 0 1 2 (When number of drives <= 1) (When number of drives = 2 or 3) (When number of drives > 3) PackageRedundancyMax 0 1 2 (When number of drives <= 1) (When number of drives = 2 or 3) (When number of drives > 3) PackageRedundancyMin 0 True HPSA_StorageCapabilities SMX_SAProduct Class The
SMX_SAStorageEnclosureLocation Class The SMX_SAStorageEnclosureLocation class implements the HPSA_StorageEnclosureLocation class and represents a location string for the enclosure. The following table lists the properties implemented. Property Name Property Implementation Enclosure location ElementName Port: Box: Where: is the port and is the box number. Enclosure location Port: Box: Where: is the port Caption and is the box number.
Property Name Property Implementation Capabilities SMX_SAStorageCapabilities ManagedElement SMX_SAPrimordialPool SMX_SAStoragePoolStorageCapabilities (Association) The following table lists the associations implemented for this class. Property Name Property Implementation Capabilities SMX_SAStorageCapabilities ManagedElement SMX_SAStoragePool SMX_SAArraySystemStorageEnclosureProcessor (Association) The following table lists the associations implemented for this class.
PartComponent SMX_SADiskDrive SMX_SAArraySystemStorageVolume (Association) The following table lists the associations implemented for this class. Property Name Property Implementation GroupComponent SMX_SAArraySystem PartComponent SMX_SAStorageVolume SMX_SAArraySystemStorageExtent (Association) The following table lists the associations implemented for this class.
SMX_SAComputerSystemArraySystem (Association) The following table lists the associations implemented for this class. Property Name Property Implementation GroupComponent HP_ComputerSystem PartComponent SMX_SAArraySystem SMX_SAArraySystemArrayController (Association) The following table lists the associations implemented for this class.
SMX_SAPhysicalPackageArrayControllerPhysicalPackage (Association) The following table lists the associations implemented for this class. Property Name Property Implementation GroupComponent SMX_SAPhysicalPackage PartComponent SMX_SAArrayControllerPhysicalPackage SMX_SAPhysicalPackageDiskPhysicalPackage (Association) The following table lists the associations implemented for this class.
SMX_SAStorageSpecificCollectionArraySystem (Association) The following table lists the associations implemented for this class. Property Name Property Implementation Collection SMX_SAStorageSpecificCollection Member SMX_SAArraySystem SMX_SAStorageRedundancySetStorageExtent (Association) The following table lists the associations implemented for this class.
ElementSoftwareStatus ElementSoftwareStatus[0]: 2 (Current) ElementSoftwareStatus[1]: 6 (Installed) SMX_SAStorageEnclosureProcessorEnclosureFirmware (Association) The following table lists the associations implemented for this class.
SMX_SADiskPhysicalPackageDiskDrive (Association) The following table lists the associations implemented for this class. Property Name Property Implementation Antecedent SMX_SADiskPhysicalPackage Dependent SMX_SADiskDrive SMX_SAStoragePoolStorageVolume (Association) The following table lists the associations implemented for this class.
SMX_SAStorageExtentStorageVolume (Association) The following table lists the associations implemented for this class. Property Name Property Implementation Antecedent SMX_SAStorageExtent Dependent SMX_SAStorageVolume SMX_SADAPortSCSIProtocolEndpoint (Association) The following table lists the associations implemented for this class.
SMX_SADiskDriveMediaAccessStatData (Association) The following table lists the associations implemented for this class. Property Name Property Implementation ManagedElement SMX_SADiskDrive Stats SMX_SAMediaAccessStatData SMX_SAArrayControllerPhysicalPackageArrayControllerLocati on (Association) The following table lists the associations implemented for this class.
SMX_SASCSIProtocolEndpointSCSIProtocolController (Association) The following table lists the associations implemented for this class. Property Name Property Implementation AvailableSAP SMX_SASCSIProtocolEndpoint ManagedElement SMX_SASCSIProtocolController SMX_SAStorageEnclosureEnclosureLocation (Association) The following table lists the associations implemented for this class.
Property Name Property Implementation SystemName The property value of HPSA_ArraySystem.
Property Name Property Implementation CIM_ManagedElement Caption Protocol Endpoint for Where: is the value populated in the ElementName property of the instance of SMX_SATSASPort associated to this instance via the association SMX_SATSASPortTSASSCSIPE ElementName Protocol Endpoint for Where: is the value populated in the ElementName property of the instance of SMX_SATSASPort associated to this instance via the association SMX_SATSASPortTSASSCSIPE CIM_ManagedSystemElement The sa
Property Name Property Implementation EnabledDefault 2 (Enabled) EnabledState 5 (Not Applicable) RequestedState 12 (Not Applicable) CIM_LogicalDevice SystemnCreationClassName SMX SAArraySystem SystemName The property value of HPSA_ArraySystem.name CreationClassName SMX_SATSASPort DeviceID The same value as the SMX_SATSASSCSIProtocolEndpoint.Name property of the instance associated through SMX_SAISASPortISASSCSIPE.
Property Name Property Implementation CIM_LogicalDevice SystemnCreationClassName SMX ArraySystem SystemName The property value of HPSA_ArraySystem.name CreationClassName SMX_SAISASPort DeviceID SMX SAPortController.DeviceIDport # Where: SMX_SAPortController.deviceID is the DeviceID property of the instance of SMX_SAPortController associated to this instance via the association SMX_SAPortControllerISASPort, and port # is the port number for the port.
Property Name Property Implementation GroupComponent SMX_SAArraySystem PartComponent SMX_SAISASPort SMX_SAPortControllerISASPort (Association) The following table lists the associations implemented for this class. Property Name Property Implementation Antecedent SMX_SAPortController Dependent SMX_SAISASPort SMX_SAArraySystemTSASSCSIProtocolEndpoint (Association) The following table lists the associations implemented for this class.
AvailableSAP SMX_SATSASSCSIProtocolEndpoint ManagedElement SMX_SADiskDrive SMX_SASCSIInitiatorTargetLogicalUnitPath The following table lists the associations implemented for this class.
Property Name Property Implementation EventTime Time of the event or time of the indication if event time unknown ProviderName HP Smart Array RecommendedActions No action is recommended.
Property Name Property Implementation RackName * Rack name if, one exists RackUID * Rack Unique Identifier, if one exists SystemVirtualSerialNumber Conditional property containing the virtual system serial number string when running in a Virtual Connect environment SystemVirtualUUID Conditional property containing the virtual system UUID when running in a Virtual Connect environment HP_HardwareIndication HWFirmwareVersion Physical Disk firmware version string HWLogicalLocation Physical Disk Loc
Property Name IndicationTime Property Implementation Time of indication CIM_AlertIndication Description A physical drive status has changed to Error. AlertingManagedElement WBEM Path of SMX_SADiskDrive class AlertingElementFormat 2 (CIMObjectPath) AlertType 5 (Device Alert) EventID 202 EventTime Time of the event or time of the indication if event time unknown ProviderName HP Smart Array RecommendedActions Check for failed or removed physical drives.
Property Name Property Implementation ImpactedDomain (Enclosure) for c-Class blade systems (System) for all other systems Note: When ImpactedDomain is 3 (Enclosure) the properties that follow and are indicated with an asterisk (*) below will be populated. BladeBay * HP_BladeCSLocation.LocationInformation[0] BladeName * HP_ComputerSystem.Name EnclosureName * HP_BladeEnclosureCS.
HP_DeviceIndication: Physical Drive Status Changed to REBUILDING Property Name Property Implementation CIM_Indication IndicationIdentifier GUID string generated at the time of indication PerceivedSeverity 2 IndicationTime Time of indication (Informational) CIM_AlertIndication Description A physical drive status has changed to Rebuilding. Data is now being rebuilt onto this drive from the RAID set.
Property Name Property Implementation indication SystemProductID Product ID of the computer system generating the indication SystemModel Model name of the computer system generating the indication SystemGUID Platform GUID of the computer system generating the indication ImpactedDomain (Enclosure) for c-Class blade systems (System) for all other systems Note: When ImpactedDomain is 3 (Enclosure) the properties that follow and are indicated with an asterisk (*) below will be populated.
Property Name VariableValues[] Property Implementation FailureDescription – short description of the failure Drive interface HPSA_DiskDrive.DriveInterface LastFailureDescription – last failure reason string from the drive. HPSA_DiskDrive.
Property Name Property Implementation Failure. NetworkAddresses Contains a list of all the IP addresses of the computer system generating the indication OSType SMX_OperatingSystem.OSType OSVersion The operating system version of the computer system generating the indication in the following format: .. ProviderVersion For example: 2.2.0.
Property Name Property Implementation HWPhysicalLocation Physical Location of the Failed Drive (Bay Number) HWSerialNumber Physical Disk Serial Number VariableNames[] FailureDescription DriveInterface LastFailureDescription VariableTypes[] String (1) uint16 (4) VariableValues[] FailureDescription – short description of the failure Drive interface HPSA_DiskDrive.DriveInterface LastFailureDescription – last failure reason string from the drive. HPSA_DiskDrive.
Property Name SystemName Property Implementation Name SystemCreationClassName of the computer system generating the indication CreationClassName indication of the computer system generating the HP_AlertIndication Summary Logical drive status OK EventCategory 6 (Primary Storage) ProbableCause 1 (Other) ProbableCauseDescription Logical Drive Status Changed to OK NetworkAddresses Contains a list of all the IP addresses of the computer system generating the indication OSType SMX_OperatingSys
Property Name SystemVirtualUUID Property Implementation Conditional property containing the virtual system UUID when running in a Virtual Connect environment HP_HardwareIndication HWLogicalLocation Logical drive number and RAID Level For example: LogicalDrive1 (RAID 1+0).
Property Name Property Implementation AlertingElementFormat 2 (CIMObjectPath) AlertType 5 (Device Alert) EventID 102 EventTime Time of the event or time of the indication if event time unknown ProviderName HP Smart Array RecommendedActions Check for failed or removed physical drives.
Property Name Property Implementation BladeBay * HP_BladeCSLocation.LocationInformation[0] BladeName * HP_ComputerSystem.Name EnclosureName * HP_BladeEnclosureCS.
SMX_SAStorageVolumeIndication: Logical Drive Status Changed to Degraded Property Name Property Implementation CIM_Indication IndicationIdentifier GUID string generated at the time of indication PerceivedSeverity 2 IndicationTime Time of indication (Info) CIM_AlertIndication Description A logical drive is in a degraded state. Device is still servicing I/O but redundancy may be degraded or lost.
Property Name Property Implementation SystemSerialNumber Serial number of the computer system generating the indication SystemProductID Product ID of the computer system generating the indication SystemModel Model name of the computer system generating the indication SystemGUID Platform GUID of the computer system generating the indication ImpactedDomain (Enclosure) for c-Class blade systems (System) for all other systems Note: When ImpactedDomain is 3 (Enclosure) the properties that follow and a
Property Name Property Implementation Current OperationStatus values for Storage Volume DeviceOperationalStatus[0]: SMX_SAStorageVolume.OperationalStatus[0] DeviceOperationalStatus[1]: SMX_SAStorageVolume.OperationalStatus[1] DeviceOperationalStatus (This index is only populated if there is additional Vendor unique status available) Previous OperationStatus values for Storage Volume DeviceOperationalStatusPrevious[0]: SMX_SAStorageVolume.
Property Name Property Implementation (Other) ProbableCause 1 ProbableCauseDescription Array Controller Status Changed to OK NetworkAddresses Contains a list of all the IP addresses of the computer system generating the indication OSType SMX_OperatingSystem.OSType OSVersion The operating system version of the computer system generating the indication in the following format: ..
Property Name Property Implementation VariableNames[] FailureDescription CacheSizeTotal CacheSerialNumber VariableTypes[] String (1) uint32 (5) VariableValues[] FailureDescription – short description of the failure CacheSizeTotal HPSA_ArrayController.CacheSizeTotal CacheSerialNumber HPSA_ArrayController.
Property Name Property Implementation ProbableCauseDescription Array Controller Status Changed to Error NetworkAddresses Contains a list of all the IP addresses of the computer system generating the indication OSType SMX_OperatingSystem.OSType OSVersion The operating system version of the computer system generating the indication in the following format: ..
Property Name Property Implementation VariableNames[] FailureDescription CacheSizeTotal CacheSerialNumber VariableTypes[] String (1) uint32 (5) VariableValues[] FailureDescription – short description of the failure CacheSizeTotal HPSA_ArrayController.CacheSizeTotal CacheSerialNumber HPSA_ArrayController.
Property Name Property Implementation ProbableCauseDescription Controller Battery Status Changed to OK NetworkAddresses Contains a list of all the IP addresses of the computer system generating the indication OSType SMX_OperatingSystem.OSType OSVersion The operating system version of the computer system generating the indication in the following format: .. ProviderVersion For example: 2.2.0.
Property Name Property Implementation VariableNames[] FailureDescription CacheSizeTotal CacheSerialNumber VariableTypes[] String (1) uint32 (5) VariableValues[] FailureDescription – short description of the failure CacheSizeTotal HPSA_ArrayController.CacheSizeTotal CacheSerialNumber HPSA_ArrayController.
Property Name Property Implementation (Primary Storage) EventCategory 6 ProbableCause 99 ProbableCauseDescription Controller Battery Status Changed to Not Fully Charged NetworkAddresses Contains a list of all the IP addresses of the computer system generating the indication OSType SMX_OperatingSystem.OSType OSVersion The operating system version of the computer system generating the indication in the following format: ..
Property Name Property Implementation VariableNames[] FailureDescription CacheSizeTotal CacheSerialNumber VariableTypes[] String (1) uint32 (5) VariableValues[] FailureDescription – short description of the failure CacheSizeTotal HPSA_ArrayController.CacheSizeTotal CacheSerialNumber HPSA_ArrayController.
Property Name Property Implementation (battery failure) ProbableCause 92 ProbableCauseDescription Controller Battery Status Changed to Failed NetworkAddresses Contains a list of all the IP addresses of the computer system generating the indication OSType SMX_OperatingSystem.OSType OSVersion The operating system version of the computer system generating the indication in the following format: ..
Property Name Property Implementation VariableNames[] FailureDescription CacheSizeTotal CacheSerialNumber VariableTypes[] String (1) uint32 (5) VariableValues[] FailureDescription – short description of the failure CacheSizeTotal HPSA_ArrayController.CacheSizeTotal CacheSerialNumber HPSA_ArrayController.
Property Name Property Implementation ProbableCauseDescription Controller Cache Status Changed to OK NetworkAddresses Contains a list of all the IP addresses of the computer system generating the indication OSType SMX_OperatingSystem.OSType OSVersion The operating system version of the computer system generating the indication in the following format: .. ProviderVersion For example: 2.2.0.
Property Name Property Implementation VariableNames[] FailureDescription CacheSizeTotal CacheSerialNumber VariableTypes[] String (1) uint32 (5) VariableValues[] FailureDescription – short description of the failure CacheSizeTotal HPSA_ArrayController.CacheSizeTotal CacheSerialNumber HPSA_ArrayController.
Property Name Property Implementation (Primary Storage) EventCategory 6 ProbableCause 35 ProbableCauseDescription Array Controller Cache Status Changed to Temporarily Disabled NetworkAddresses Contains a list of all the IP addresses of the computer system generating the indication OSType SMX_OperatingSystem.OSType OSVersion The operating system version of the computer system generating the indication in the following format: ..
Property Name Property Implementation VariableNames[] FailureDescription CacheSizeTotal CacheSerialNumber VariableTypes[] String (1) uint32 (5) VariableValues[] FailureDescription – short description of the failure CacheSizeTotal HPSA_ArrayController.CacheSizeTotal CacheSerialNumber HPSA_ArrayController.
Property Name Property Implementation (Primary Storage) EventCategory 6 ProbableCause 35 ProbableCauseDescription Array Controller Cache Status Changed to Permanently Disabled NetworkAddresses Contains a list of all the IP addresses of the computer system generating the indication OSType SMX_OperatingSystem.OSType OSVersion The operating system version of the computer system generating the indication in the following format: ..
Property Name Property Implementation HWSerialNumber Array Controller Serial Number VariableNames[] FailureDescription CacheSizeTotal CacheSerialNumber VariableTypes[] String (1) uint32 (5) VariableValues[] FailureDescription – short description of the failure CacheSizeTotal HPSA_ArrayController.CacheSizeTotal CacheSerialNumber HPSA_ArrayController.
Property Name Property Implementation Summary Power Supply status Non-Redundant EventCategory 17 (Primary Storage Power) ProbableCause 89 (Power Supply Failure) ProbableCauseDescription Redundant Power Supply Status Changed to Non-Redundant NetworkAddresses Contains a list of all the IP addresses of the computer system generating the indication OSType SMX_OperatingSystem.
Property Name DeviceModel Property Implementation Enclosure Model string HP_DeviceIndication: Enclosure Power Supply Status changed to OK (Redundant) Property Name Property Implementation CIM_Indication IndicationIdentifier GUID string generated at the time of indication PerceivedSeverity 2 IndicationTime Time of indication (Info) CIM_AlertIndication Description A Storage Enclosure Power Subsystem has changed to Fully Redundant.
Property Name Property Implementation SystemProductID Product ID of the computer system generating the indication SystemModel Model name of the computer system generating the indication SystemGUID Platform GUID of the computer system generating the indication ImpactedDomain (Enclosure) for c-Class blade systems (System) for all other systems Note: When ImpactedDomain is 3 (Enclosure) the properties that follow and are indicated with an asterisk (*) below will be populated.
Property Name Property Implementation AlertingElementFormat 2 (CIMObjectPath) AlertType 5 (Device Alert) EventID 303 EventTime Time of the event or time of the indication if event time unknown ProviderName HP Smart Array RecommendedActions Check status of all enclosure power supplies. Ensure that power supplies have not failed. Add or replace power supplies as necessary.
Property Name Property Implementation RackUID * Rack Unique Identifier, if one exists SystemVirtualSerialNumber Conditional property containing the virtual system serial number string when running in a Virtual Connect environment SystemVirtualUUID Conditional property containing the virtual system UUID when running in a Virtual Connect environment HP_HardwareIndication HWLogicalLocation Enclosure Location string For example: Port 1I Box 1 HWSerialNumber Enclosure Serial Number HP_DeviceIndication
Property Name Property Implementation (Other) ProbableCause 1 ProbableCauseDescription Temperature Status Changed to OK NetworkAddresses Contains a list of all the IP addresses of the computer system generating the indication OSType SMX_OperatingSystem.OSType OSVersion The operating system version of the computer system generating the indication in the following format: ..
HP_DeviceIndication: Enclosure Temperature sensor Status Changed to Warning Property Name Property Implementation CIM_Indication IndicationIdentifier GUID string generated at the time of indication PerceivedSeverity 3 IndicationTime Time of indication (Warning) CIM_AlertIndication Description A Storage Enclosure Temperature sensor status changed to Warning Condition. This indicates the enclosure temperature is above normal, otherwise enclosure is still operating normally.
Property Name Property Implementation SystemProductID Product ID of the computer system generating the indication SystemModel Model name of the computer system generating the indication SystemGUID Platform GUID of the computer system generating the indication ImpactedDomain (Enclosure) for c-Class blade systems (System) for all other systems Note: When ImpactedDomain is 3 (Enclosure) the properties that follow and are indicated with an asterisk (*) below will be populated.
Property Name Property Implementation before loss of data occurs. AlertingManagedElement WBEM Path of SMX_SAStorageEnclosureProcessor AlertingElementFormat 2 (CIMObjectPath) AlertType 5 (Device Alert) EventID 309 EventTime Time of the event or time of the indication if event time unknown ProviderName HP Smart Array RecommendedActions Ensure that the system is adequately ventilated. Check for proper room temperature and internal/external airflow.
Property Name Property Implementation BladeBay * HP_BladeCSLocation.LocationInformation[0] BladeName * HP_ComputerSystem.Name EnclosureName * HP_BladeEnclosureCS.
Property Name Property Implementation HP_AlertIndication Summary Fan status OK EventCategory 24 ProbableCause 1 ProbableCauseDescription Fan Status Changed to OK NetworkAddresses Contains a list of all the IP addresses of the computer system generating the indication OSType SMX_OperatingSystem.OSType OSVersion The operating system version of the computer system generating the indication in the following format: ..
Property Name Property Implementation HP_DeviceIndication DeviceModel Enclosure Model string HP_DeviceIndication: Enclosure Fan Status changed to Degraded Property Name Property Implementation CIM_Indication IndicationIdentifier GUID string generated at the time of indication PerceivedSeverity 3 IndicationTime Time of indication (Warning) CIM_AlertIndication Description A Storage Enclosure Fan status has changed to Degraded.
Property Name Property Implementation ProviderVersion For example: SystemFirmwareVersion Firmware version of the computer system generating the indication SystemSerialNumber Serial number of the computer system generating the indication SystemProductID Product ID of the computer system generating the indication SystemModel Model name of the computer system generating the indication SystemGUID Platform GUID of the computer system generating the indication 2.2.0.
Property Name Property Implementation enclosure has detected a failure in the fan subsystem and there is insufficient fan capability to ensure normal operation. AlertingManagedElement WBEM Path of SMX_SAStorageEnclosureProcessor AlertingElementFormat 2 (CIMObjectPath) AlertType 5 (Device Alert) EventID 306 EventTime Time of the event or time of the indication if event time unknown ProviderName HP Smart Array RecommendedActions Ensure that the system is adequately ventilated.
Property Name Property Implementation ImpactedDomain (Enclosure) for c-Class blade systems (System) for all other systems Note: When ImpactedDomain is 3 (Enclosure) the properties that follow and are indicated with an asterisk (*) below will be populated. BladeBay * HP_BladeCSLocation.LocationInformation[0] BladeName * HP_ComputerSystem.Name EnclosureName * HP_BladeEnclosureCS.
Physical Location The Physical Location is a string representing the Smart Array device physical location. This string should represent the physical location of the device with which an end-user can uniquely locate the device. Most of these strings will be represented in customer documentation, silkscreen labels, or hood tags. The following table lists the properties implemented. Any combination of the following applicable descriptors could be used to better define the device location.
HP Insight Manager WBEM System Fan Provider Overview The HP Insight Management Web-Based Enterprise Management (WBEM) System Fan provider implements and extends CIM classes described in this document to model the base server. These classes provide computational information and capabilities and serve as an aggregation point to associate one or more elements that make up a base server, such as: Fans, PowerSupplies, Processor and Memory (Volatile and/or NonVolatile Storage).
SMX_FanSlot SMX_FanInSlot SMX_SystemFanSlot SMX_FanSpeedSensor SMX_AssociatedFanSensor SMX_SystemFanSensor The tables in the following sections describe the properties of the supported classes. The classes are categorized by the class or superclass that defines the property, the first column is the Property Name (including type and units) and the second column describes how the provider determines the properties implementation.
Property Name Property Implementation StatusDescriptions[0] Description of the status of the fan corresponding to the OperationalStatus.
The following table lists the properties implemented. Property Name Property Implementation CIM_ManagedElement Caption Cooling Collection This is a collection of all devices including fans that provide cooling. Description ElementName GroupStatusDescription Where: GroupStatusDescription represents GroupStatusDescriptions[0] property. the value of the Cooling Collection CIM_SystemSpecificCollection InstanceID Unique identifier for this cooling collection instance.
Property Name Property Implementation CIM_ManagedElement Short description of this redundancy set, for example: Cooling Caption Description ElementName Redundancy Set Where: represents the number of the redundancy set instance. Description of this redundancy set For example: Cooling Redundancy Set is collection of fault tolerant fans that provide redundant cooling Where: represents the number of the redundancy set instance. User printable name for this cooling redundancy set.
Collection References HP_FanRedundancySet Member References HP_Fan SMX_HostedFanRedundancySet Class The SMX_HostedFanRedundancySet class is used to represent an association between HP_FanRedundancySet and the computer system that contains this redundancy set. The following table lists the properties implemented.
The following table lists the properties implemented. Property Name Property Implementation GroupComponent References HP_ComputerSystem PartComponent References HP_Fan SMX_FanLocation Class The SMX_FanLocation class is used to model fan locations on servers. The following table lists the properties implemented. Property Name Property Implementation CIM_ManagedElement Caption Short description of this fan location, including the name displayed by the MP or iLO.
SMX_FanElementLocation Class The SMX_FanElementLocation class is used to represent an association between the CIM_Location and CIM_ManagedElement classes. The following table lists the properties implemented. Property Name Property Implementation Element References CIM_ManagedElement PhysicalLocation References CIM_Location SMX_FanModule Class The SMX_FanModule class is used to model physical fans on servers. Fan numbers for existing instances do not change when other fans are added and removed.
Property Name Property Implementation StatusDescriptions[0] Description of the status of the fan corresponding to the OperationalStatus. For example: Fan is operating properly – if OperationalStatus[0] is 2 (OK); Fan is degraded – if OperationalStatus[0] is 3 (Degraded) Fan has failed – if OperationalStatus is 6 (Error) HealthState 5 (OK) – if fan is operating properly; 10 (Degraded) if fan is degraded 20 (Major Failure) – if fan has failed Name of this fan module.
Antecedent References HP_FanModule Dependent References HP_Fan SMX_FanSlot Class The SMX_FanSlot class is used to model physical fan slots on servers. The following table lists the properties implemented. Property Name Property Implementation CIM_ManagedElement Caption Short description of this fan slot, to include the number and location. For example: Fan 1 at CabinetFan=01 Description Description of the fan slot. For example: Fan 1 at CabinetFan=01 ElementName Name of the fan slot.
Property Name Property Implementation GroupComponent References HP_ComputerSystemChassis PartComponent References HP_FanSlot SMX_FanInSlot Class The SMX_FanInSlot class implements the HP_FanInSlot class and associates the HP_FanSlot instance with HP_FanModule instances. The following table lists the properties implemented.
Property Name Property Implementation Name of fan speed sensor from the name displayed by the MP or iLO and the location. For example: Fan speed sensor for Fan 1 at CabinetFan=01 Name CIM_LogicalDevice CreationClassName SMX_FanSpeedSensor DeviceID Unique identifier for fan slot. SystemCreationClassName HP_ComputerSystem.CreationClassName SystemName HP_ComputerSystem.
SMX_AssociatedFanSensor SMX_AssociatedFanSensor is used to represent an association SMX_FanSpeedSensor that is reporting the speed of the fan. Property Name between HP_Fan and the Property Implementation Antecedent References SMX_FanSpeedSensor Dependent References SMX_Fan Provider Indications Indications Generated by the Provider The following tables describe the SMX WBEM System Fan Provider indications that are implemented for HP ProLiant server platforms, where available.
Property Name Property Implementation SystemGUID Platform GUID of the computer system generating the indication. SystemVirtualUUID[] If Synergy is enabled, this will contain the logical UUID for the system. SystemVirtualSerialNumber[] If Synergy is enabled, this will contain the logical Serial Number for the system. EnclosureName HP_BladeEnclosureCS.Name RackName Rack name, if one exists RackUUID Rack Unique Identifier, if one exists BladeName HP_ComputerSystem.
HP_DeviceIndication: Fan Inserted Property Name Property Implementation CIM_Indication PerceivedSeverity 2 (Information) CIM_AlertIndication Description A fan has been inserted. Where: is the SMX_Fan.Caption for the fan that has been inserted. AlertingManagedElement WBEM Path of SMX_Fan instance representing the inserted fan.
Property Name ProbableCause Property Implementation 94 (Fan Failure) ProbableCauseDescription Fan Failed HP_DeviceIndication: Fan Repaired Property Name Property Implementation CIM_Indication PerceivedSeverity 2 (Information) CIM_AlertIndication A fan has been repaired. The fan is now operating properly. Description Where: is the SMX_Fan.Caption for the fan that has been repaired. AlertingManagedElement WBEM Path of SMX_Fan instance representing the failed fan.
Property Name Property Implementation AlertingElementFormat 2 (CIMObjectPath) AlertType 5 (Device Alert) EventID 9 ProviderName HP Cooling RecommendedActions Check the degraded fan and replace if necessary.
Property Name PerceivedSeverity Property Implementation 4 (Minor) CIM_AlertIndication Description Cooling redundancy has been lost. ) Where: represents the SMX_FanRedundancySet.Caption for the redundancy set that lost redundancy. AlertingManagedElement WBEM Path of SMX_FanRedundancySet instance representing the redundancy set where redundancy was lost.
Property Name Property Implementation HP_AlertIndication Summary Cooling redundancy restored EventCategory 23 ProbableCause 1 (System Cooling) (Other) ProbableCauseDescription Cooling Redundancy has been Restored HP_DeviceIndication: Fan Redundancy Failed Important: This indication is not supported on HP ProLiant systems because redundancy set failure, which is failure beyond redundancy lost, will cause system shutdown.
HP Insight Management WBEM System Memory Provider The HP Insight Management Web-Based Enterprise Management (WBEM) System Memory provider implements the HP Memory Profile and HP Memory Physical Asset Profile to represent system memory on HP servers. Description This provider implements the following profiles and installs the necessary files: Profile Name Organization Version HP Memory Profile HP WBEM TC 1.0 HP Memory Physical Asset Profile HP WBEM TC 1.0 HP Location Profile HP WBEM TC 1.2.
SMX_SystemMemoryBoard SMX_MemoryRedundancySet SMX_MemoryCollection SMX_HostedMemoryCollection SMX_MemberOfMemoryCollection SMX_MemberOfMemoryRedundancySet SMX_HostedMemoryRedundancySet SMX_SystemMemoryModuleSlot SMX_SystemMemoryBoardSlot The tables in the following sections describe the properties of the supported classes.
Property Name Property Implementation StatusDescriptions StatusDescriptions[0]contains OperationalStatus[0]: OK Unknown Degraded descriptive text per HealthState 5 (OK), when OperationalStatus[0] = 2 (OK) 0 (Unknown), when OperationalStatus[0] = 0 (Unknown) 10 (Degraded/Warning), when OperationalStatus[0]=3 (Degraded) Name System Memory CIM_LogicalElement CIM_EnabledLogicalElement EnabledDefault 2 (Enabled) EnabledState 5 (Not Applicable) RequestedState 12 (Not Applicable) CIM_LogicalDevice
SMX_SystemMemory Class The SMX_SystemMemory class represents an association between SMX_Memory and the computer system that contains the memory. There is one instance of this class. The following table lists the properties implemented. Property Name Property Implementation CIM_SystemDevice HP_SystemMemory GroupComponent References SMX_ComputerSystem PartComponent References SMX_Memory SMX_SystemMemory SMX_MemoryModule Class The SMX_MemoryModule class represents a physical memory module on HP servers.
Property Name Property Implementation HealthState Enumerator indicating the memory module health state: 0 (Unknown), when OperationalStatus[0] = 0 (Unknown) 5 (OK), when OperationalStatus[0] = 2 (OK) 10 (Degraded/Warning), when OperationalStatus[0] = 3 (Degraded) Name Physical Memory Module . Refer to “Physical Location” for more information.
Property Name Property Implementation property is IsSpeedInMhz=TRUE. MaxMemorySpeed The maximum speed in MHz of PhysicalMemory MemoryType Enumerator indicating the type of memory module. Refer to MOF file for details. PositionInRow Position of memory module in a row. This property is conditional; it is populated if the data is available FormFactor Enumerator indicating the form factor of the memory module. Refer to MOF file for details.
SMX_MemoryBoard Class The SMX_MemoryBoard class represents a physical memory board on HP servers. There is an instance of this class for each memory module present in the system; empty memory module sockets are not instantiated. The following table lists the properties implemented. Property Name Property Implementation CIM_ManagedElement Caption Physical Memory . Refer to “Physical Location” for more information.
Property Name Property Implementation RemovalConditions Removal conditions of the memory board: When the memory board is the system board: 2 (Not Applicable) When the memory board is not the system board: 3 (Removable when off) 4 (Removable when on or off) PackageType 9 (Module/Card) CIM_Card HostingBoard True – memory board is on the baseboard.
OperationalStatus[0] OperationalStatus[1] StatusDescriptions[0] StatusDescriptions[1] Condition memory modules on the board. SMX_RealizesMemoryModule Class The SMX_RealizesMemoryModule class represents an association between SMX_MemoryModule and SMX_Memory. The following table lists the properties implemented.
Property Name Property Implementation Description Memory Module . Refer to “Physical Location” for more information. ElementName Memory Module . Refer to “Physical Location” for more information. CIM_PhysicalConnector ConnectorLayout 1 (Other) ConnectorGender 3 (Female) ConnectorDescription Memory Module . Refer to “Physical Location” for more information. CIM_Slot The memory socket number where the memory slot is located.
Property Name Property Implementation (Other) ConnectorLayout 1 ConnectorDescription Memory Board Slot . Refer to “Physical Location” for more information. CIM_Slot Number The board/cartridge number where the memory board is located. Note: Not unique on HP Cellular servers. SMX_MemoryBoardSlot SMX_MemoryModuleInSlot Class The SMX_MemoryModuleInSlot class represents the association between an SMX_MemoryModule and the SMX_MemoryModuleSlot where it resides.
Property Name Property Implementation CIM_Container HP_MemoryModuleSlotOnBoard SMX_MemoryModuleSlotOnBoard GroupComponent References SMX_MemoryBoard PartComponent References SMX_MemoryModuleSlot SMX_MemoryModuleSlotLocation Class The SMX_MemoryModuleSlotLocation class extends the CIM_Location class and represents memory module slot locations on HP servers. There is an instance of this class for each memory module slot in the system (whether the slot is occupied or not).
Property Name LocationInfoDesc Property Implementation Array indices will report as many of the following enumerated values as are applicable: 4 (Socket) 5 (Memory Board) 7 (Cabinet) 10 (Cell) 14 (BladeBay) 15 (ProcessorBoard) SMX_MemoryModuleSlotLocation SMX_MemoryBoardSlotLocation Class The SMX_MemoryBoardSlotLocation class extends the CIM_Location class and represents memory board slot locations on HP servers.
Property Name Property Implementation LocationInformation text: Where: is the board/cartridge/processor number Location information will contain a numeric string representing the unique location identifier of each object type described by the corresponding LocationInfoDesc index.
Property Name Property Implementation HP_ElementLocation SMX_MemoryBoardSlotElementLocation Element References SMX_MemoryBoardSlot PhysicalLocation References SMX_MemoryBoardSlotLocation SMX_SystemMemoryModule Class The SMX_SystemMemoryModule class represents an association between SMX_MemoryModule and SMX_ComputerSystemChassis. There is an instance of this class for each memory module slot on the chassis system board (whether the slot is occupied or not).
The following table lists the properties implemented. Property Name Property Implementation CIM_ManagedElement Caption Memory Redundancy Set Description Memory Redundancy Set for Advanced Memory Protection ElementName Memory Redundancy Set CIM_SystemSpecificCollection InstanceID HPQ:SMX_MemoryRedundancySet:001 CIM_RedundancySet TypeOfSet OtherTypeOfSet Represents the type of redundancy currently in operation for the Advanced Memory Protection system.
Property Name Property Implementation TotalMemory Total size of memory as seen by the operating system and memory used for Advanced Memory Protection configurations in MB CurrentConfiguration The current operating mode of the Advanced Memory Protection system. The value in this property corresponds to the value populated in the property TypeOfSet[0].
Property Name Property Implementation Caption Memory Collection Description Physical memory collection ElementName Memory Collection CIM_SystemSpecificCollection InstanceID HPQ:SMX_MemoryCollection:001 HP_GroupSystemSpecificCollection Enumerator indicating the group operational status of the memory collection.
- 0 (Unknown) 2 (OK) 0 (Unknown) - 0 (Unknown) 3 (Degraded) 3 (Degraded) - 0 (Unknown) 0 (Unknown) 0 (Unknown) SMX_HostedMemoryCollection Class The SMX_HostedMemoryCollection class represents an association between SMX_MemoryCollection and the computer system that contains this collection. The following table lists the properties implemented.
Property Name Property Implementation CIM_MemberOfCollection HP_MemberOfMemoryRedundancySet SMX_MemberOfMemoryRedundancySet Collection References SMX_MemoryRedundancySet Member References SMX_MemoryBoard SMX_HostedMemoryRedundancySet Class The SMX_HostedMemoryRedundancySet class represents an association between SMX_MemoryRedundancySet and the computer system that contains this redundancy set. The following table lists the properties implemented.
SMX_SystemMemoryBoardSlot Class The SMX_SystemMemoryBoardSlot class represents an association between SMX_MemoryBoardSlot and SMX_ComputerSystemChassis. There is an instance of this class for each memory board slot in the chassis (whether the slot is occupied or not). The following table lists the properties implemented.
Property Name Property Implementation On ESX, 39 (VM) On Linux, 36 (Linux) OSType The operating system version of the computer system generating the indication in the following format: OSVersion ..
Property Name Property Implementation EventID 1 ProviderName HP Memory RecommendedActions Check the memory configuration and replace memory as necessary.
Property Name Property Implementation operating with degraded redundancy. The targeted configuration has degraded or is operating with memory modules that have failed or predicted to fail. (TargetConfiguration/CurrentConfiguration) Where: TargetConfiguration is SMX_MemoryRedundancySet.TargetConfiguration. AlertingManagedElement WBEM Path of SMX_MemoryRedundancySet instance representing the Memory Redundancy.
Property Name Property Implementation Summary Advanced Memory Protection redundancy is now fully operational EventCategory 3 (Memory) ProbableCause 1 (Other) ProbableCauseDescription Advanced Memory Protection now Fully Operational Physical Location Memory Physical Location is a string representing the physical location of a Memory device, such as DIMM, slot, socket, board, or extender.