HP Insight Management WBEM Providers for HP integrated VMware ESXi Data Sheet

HP Insight Manager WBEM Ethernet 117
HP_AlertIndication: Ethernet Team Member Dropped
Property Name Property Implementation
CIM_Indication
PerceivedSeverity
2 (Information)
CIM_Alertindication
Description
A team member was dropped from the team via the HP Network
Configuration Utility (NCU). This is an optional indication that can be
disabled via the Ethernet Event Provider settings.
AlertingManagedElement
WBEM Path of SMX_EthernetTeam instance reporting a dropped
team member.
AlertingElementFormat
2 (CIMObjectPath)
AlertType
2 (Communications Alert)
EventID 8
ProviderName
HP Ethernet
RecommendedActions
Check the Ethernet Team and Ethernet Team Member status. View the
System Event Log for additional information.
HP_AlertIndication
Summary
Ethernet Team Member Dropped from Team.
EventCategory
9 (Network Device)
EventSubCategory
12 (Ethernet team)
ProbableCause
1 (Other)
ProbableCauseDescription
Ethernet Team Member Dropped from Team
HP_AlertIndication: Ethernet Team Member Added
Property Name Property Implementation
CIM_Indication
PerceivedSeverity
2 (Information)
CIM_Alertindication
Description
A new team member has been added to an Ethernet team via the HP
Network Configuration Utility (NCU). This is an optional indication that
can be disabled via the Ethernet Event Provider settings.
AlertingManagedElement
WBEM Path of SMX_EthernetTeam instance reporting lost
redundancy.
AlertingElementFormat
2 (CIMObjectPath)
AlertType
2 (Communications Alert)
EventID 7
ProviderName
HP Ethernet