HP Insight Management WBEM Providers for HP integrated VMware ESXi Data Sheet

HP Insight Management WBEM Management Processor Lite Provider 150
Property Name Property Implementation
Light Out 100 (LO100) (Active)
CIM_ManagedSystemElement
OperationalStatus
Enumerators indicating the Management Processor operational status (refer
to OperationalStatus mapping table in HP Management Processor Lite Profile
for specific descriptions of when each value is populated).
OperationalStatus[0] contains MP operational status:
0 (Unknown), when NICCondition=0
2 (OK), normal operation
3 (Degraded), when NICCondition=5
6 (Error), when NICCondition=6 or MP software interface fails
OperationalStatus[1] contains NIC status (when MP is enabled):
0 (Unknown), when NICCondition=0 or MP software interface fails
2 (OK), normal operation
3 (Degraded), when NICCondition=5
6 (Error), when NICCondition=6
10 (Stopped), when NICCondition=3
15 (Dormant), when NICCondition=4
Note:
When a Management Processor is disabled (refer to property EnabledState)
OperationalStatus[0] will always report a status of 2 (OK) so as not to
contribute negatively to overall system status. An MP is disabled only if the
user has manually disabled it via the MP’s RBSU settings; this is seen as a
normal condition. In this scenario OperationalStaus[1] is not populated.