HP Insight Management WBEM Providers for HP integrated VMware ESXi Data Sheet

HP Insight Management WBEM Management Processor Lite Provider 151
Property Name Property Implementation
StatusDescriptions
Descriptive text per OperationalStatus.
StatusDescriptions[0] text per OperationalStatus[0]:
Management Processor Status: Unknown
Management Processor Status: OK
Management Processor Status: Degraded
Management Processor Status: Error
StatusDescriptions[1] text per OperationalStatus[1]:
Management Processor NIC Status: Unknown
Management Processor NIC Status: OK
Management Processor NIC Status: NIC disconnected
Management Processor NIC Status: NIC failed
Management Processor NIC Status: NIC is disabled
Management Processor NIC Status: Not in use, MP is utilizing host NIC
HealthState
0 (Unknown), when OperationalStatus[0]=0 (Unknown)
5 (OK), normal operation
10 (Degraded/Warning), when OperationalStatus[0]=3 (Degraded)
20 (Major failure), when OperationalStatus[0]=6 (Error)
Note:
When a Management Processor is disabled (refer to property EnabledState)
HealthState will always report a state of 5 (OK) so as not to contribute
negatively to overall system status. An MP is disabled only if the user has
manually disabled it via the MP’s RBSU settings; this is seen as a normal
condition.
CIM_LogicalElement
CIM_EnabledLogicalElement
EnabledState
2 (Enabled) for active MP
3 (Disabled) for inactive/disabled MP
Note:
The Active MP may be enabled or disabled (the user can manually disable the
MP via RBSU settings). The Inactive MP is always disabled.
RequestedState
12
(
Not Applicable
)
EnabledDefault
2
(
Enabled
)
CIM_System
CreationClassName
SMX_ManagementProcessor
Name
Opaque instance identifier using
HPQ
as the
OrgID
. For example: