HP Insight Management WBEM Providers for HP integrated VMware ESXi Data Sheet

HP Insight Management Power Supply Provider Overview 176
SMX_MemberOfPowerRedundancy
SMX_HostedPowerRedundancySet
SMX_MemberOfPowerCollection
SMX_HostedPowerCollection
SMX_SystemPowerSupply
SMX_PowerSupplyLocation
SMX_PowerSupplyElementLocation
SMX_PowerSupplyModule
SMX_SystemPhysicalPowerSupply
SMX_RealizesPowerSupply
SMX_PowerMeter
SMX_AssociatedPowerMeter
SMX_SystemPowerMeter
SMX_PowerControllerFirmware
SMX_PowerControllerInstalledFirmwareIdentity
SMX_PowerControllerElementFirmwareIdentity
The tables in the following sections describe the properties of the supported classes. The classes are
categorized by the class or superclass that defines the property, the first column is the property name
(including type and units) and the second column describes how the provider determines the
properties implementation. When the property implementation value is a number, the number given
is the default behavior and the Managed Object Format interpretation is within parenthesis. If other
values are returned, a problem is indicated.
Unless otherwise noted, all of the property implementation values given are for HP ProLiant and HP
Integrity (cellular and non-cellular) systems. The location related properties and implementation
values are determined based on the server type so they may differ.
SMX_PowerSupply Class
The SMX_PowerSupply class is used to model power supplies on servers. Power supply numbers for
existing instances do not change when other power supplies are added and removed.
The following table lists the properties implemented.
Property Name Property Implementation
CIM_ManagedElement
Caption
Short description of this power supply for the name displayed by the
MP or iLO and its location.
For example:
Power Supply1 at PowerSupplySlot=2, Power Supply 1a at
PowerSupplySlot=2