HP Insight Management WBEM Providers for HP integrated VMware ESXi Data Sheet

HP Insight Management Power Supply Provider Overview 180
Property Name Property Implementation
ElementName
User printable name for this power redundancy set.
For example:
Power Redundancy Set <n>
Where: <n> represents the number of the redundancy set instance.
CIM_SystemSpecificCollection
InstanceID
Unique identifier for this power redundancy instance.
CIM_RedundancySet
MaxNumberSupported
Represents the maximum number of power supplies supported for this
redundancy set.
MinNumberNeeded
Represents the minimum number of power supplies needed to function.
TypeOfSet
3 (Load Balanced)
LoadBalanceAlgorithm
0 (Unknown)
RedundancyStatus
0 (Unknown) – if the redundancy status is unknown;
2 (Fully Redundant) – if the all power supplies in the set are operating
properly and enough to achieve redundancy;
3 (Degraded Redundancy) – if there are at least enough power supplies for
the redundancy set to provide power, but power supplies have failed;
4 (Redundancy Lost) – if there are not enough power supplies required to
achieve redundancy, but enough for the redundancy set to provide power;
5 (Overall Failure) – if there are not enough power supplies operating
properly for the redundancy set to provide power.
SMX_MemberOfPowerRedundancy Class
The SMX_MemberOfPowerRedundancy class is used to represent an association between
HP_PowerSupply and HP_PowerRedundancySet.