HP Insight Management WBEM Providers for HP integrated VMware ESXi Data Sheet

HP Insight Management Power Supply Provider Overview 183
Property Name Property Implementation
HP_Location
ElementLocationTag
Location string based on ElementLocationTagDesc.
For example, on HP Proliant:
Power Supply <n>
Where : <n> represents the power supply position printed on the
system.
ElementLocationTagDesc
On HP Proliant: 0 (HoodTag)
LocationInfoDesc
An array of tags describing the corresponding location path information
contained in the LocationInformation property array.
LocationInformation
An array of string values describing the location path of a managed
element containment hierarchy.
SMX_PowerSupplyElementLocation Class
The SMX_PowerSupplyElementLocation class is used to represent an association between the
CIM_Location and CIM_ManagedElement classes.
The following table lists the properties implemented.
Property Name Property Implementation
Element
References CIM_ManagedElement
PhysicalLocation
References CIM_Location
SMX_PowerSupplyModule Class
The SMX_PowerSupplyModule class is used to model physical power supplies on servers. Power
supply numbers for existing instances do not change when other power supplies are added and
removed.
The following table lists the properties implemented.
Property Name Property Implementation
CIM_ManagedElement
Caption
Short description of this power supply for the name displayed by the MP
or iLO and its location.
For example:
Power Supply1 at PowerSupplySlot=2, Power Supply 1a at
PowerSupplySlot=2