HP Insight Management WBEM Providers for HP integrated VMware ESXi Data Sheet

HP Insight Management Power Supply Provider Overview 184
Property Name Property Implementation
Description
Description of this power supply module, including ElementName,
Type and Status.
For example:
ElementName provides power for PowerSupplyType.
StatusDescription
Where: ElementName represents the value of ElementName,
PowerSupplyType represents the corresponding string value of the
PowerSupplyType enumeration and StatusDescription represents the
value of StatusDescriptions[0].
ElementName
Short description of this power supply for the name displayed by the MP
or iLO and its location.
For example:
Power Supply1 at PowerSupplySlot=2, Power Supply 1a at
PowerSupplySlot=2
CIM_ManagedSystemElement
OperationalStatus[0]
2 (OK) – if power supply is operating properly;
3 (Degraded) – if power supply is degraded;
6 (Error) – if power supply has failed
StatusDescriptions[0]
Description of the status of the power supply corresponding to the
OperationalStatus.
For example:
Power Supply is operating properly – if OperationalStatus[0]
is 2 (OK);
Power Supply is degraded – if OperationalStatus[0] is 3
(Degraded)
Power Supply has failed – if OperationalStatus is 6 (Error)
HealthState
5 (OK) – if power supply is operating properly;
10 (Degraded) if power supply is degraded
20 (Major Failure) – if power supply has failed
Name
Short description of this power supply for the name displayed by the MP
or iLO and its location.
For example:
Power Supply1 at PowerSupplySlot=2, Power Supply 1a at
PowerSupplySlot=2
CIM_PhysicalElement
CreationClassName SMX_PowerSupplyModule
PartNumber
The part number assigned by the organization that is responsible for
producing or manufacturing the PhysicalElement.
SerialNumber
A manufacturer-allocated number used to identify the Physical Element.