HP Insight Management WBEM Providers for HP integrated VMware ESXi Data Sheet

HP Insight Management Power Supply Provider Overview 187
SMX_SystemPowerSupplySlot Class
The SMX_SystemPowerSupplySlot class extends the CIM_Container class and association of the
HP_ComputerSystemChassis instance with HP_PowerSupplySlot.
The following table lists the properties implemented.
Property Name Property Implementation
GroupComponent
References HP_ComputerSystemChassis
PartComponent
References HP_PowerSupplySlot
SMX_PowerSupplyInSlot Class
The SMX_PowerSupplyInSlot class extends the CIM_ElementInConnector class and associates the
HP_PowerSupplySlot instance with HP_PowerSupplyModuleinstances.
The following table lists the properties implemented.
Property Name Property Implementation
Antecedent
References HP_PowerSupplySlot
Dependent
References HP_PowerSupplyModule
SMX_Power Meter
SMX_PowerMeter is used to model power utilization on Servers. Please note: power supply
numbers for existing instances do not change when other power supplies are added and removed.
Not all systems support reporting power utilization .
Property Name Property Implementation
CIM_ManagedElement
Caption
Short description of this power utilization sensor using the name of the
power supply displayed by the MP or iLO and its location.
For example:
Power utilization sensor for Power Supply 1 at
PowerSupplySlot=1
Description
Description of this power utilization sensor including the Caption
and StatusDescriptions.
For example:
Power utilization sensor for Power Supply 1 at
PowerSupplySlot=1
Where: StatusDescription represents the value of
StatusDescriptions[0]