HP Insight Management WBEM Providers for HP integrated VMware ESXi Data Sheet

HP Insight Manager WBEM Base Server Provider Overview 17
Property Name Property Implementation
PrimaryOwnerName
Computer system primary owner name string; initialized to not
set.
PrimaryOwnerContact
Computer system primary owner contact string; initialized to
not
set.
PrimaryOwnerPager
Computer system primary owner pager string; initialized to not
set.
SecondaryOwnerContact
Computer system secondary owner contact string; initialized to
not set.
SecondaryOwnerName
Computer system secondary owner name string; initialized to
not
set.
SecondaryOwnerPager
Computer system secondary owner pager string; initialized to
not
set.
LocationIndicator
State of the computer system Unit Identifier (UID) LED:
0 (Unknown)
2 (On)
3 (Off)
5 (Alternating)
SerialNumber
The computer system physical serial number string.
IdentifyingNumber
The computer system physical GUID string.
Model
The computer system model string.
SMX_ComputerSystem
1-1-1-1 Implemented Methods for SMX_ComputerSystem Class
Method Name Method Implementation
SendTestIndication
Method Parameters:
EventID, number of test event to send:
101 - Send Information Test Indication
102 - Send Warning Test Indication
103 - Send Critical Test Indication
Return Values:
0 - request to send indication successful
1 - method unsupported
2 - request to send indication failed
3 - provider is busy processing previously requested indication, try
again
4 - EventID is not one of the defined values
Exception: CIM_ERR_INVALID_PARAMETER - EventID is the wrong
type, does not exist or other internal error.