HP Insight Management WBEM Providers for HP integrated VMware ESXi Data Sheet

HP Insight Management Power Supply Provider Overview 188
Property Name Property Implementation
ElementName
Short description of this power utilization sensor using the name of the
power supply displayed by the MP or iLO.
For example:
Power utilization sensor for Power Supply 1
CIM_ManagedSystemElement
OperationalStatus[0]
2 (OK) – if power utilization sensor is operating properly;
StatusDescriptions[0]
Description of the status of the power utilization sensor corresponding
to the OperationalStatus.
For example:
Power Supply is operating properly – if OperationalStatus[0]
is 2 (OK);
HealthState
5 (OK) – if power utilization sensor is operating properly;
Name
Short description of this power utilization sensor using the name of the
power supply displayed by the MP or iLO and location.
For example:
Power utilization sensor for Power Supply 1 at
PowerSupplySlot=1.
CIM_LogicalDevice:
CreationClassName
SMX_PowerMeter
DeviceID
Unique identifier for this power utilizaton sensor.
SystemCreationClassName
SMX_ComputerSystem.CreationClassName
SystemName
SMX_ComputerSystem.Name
CIM_EnabledLogicalElement
EnabledDefault
2 (Enabled)
EnabledState
5 (Not Applicable)
RequestedState
12 (Not Applicable)
CIM_Sensor
SensorType
13 (Power Consumption)
CurrentState
“Normal”
PossibleStates
Array may contain the following value:
PossibleStates[0] = “Normal”
CIM_NumericSensor
CurrentReading
Current reading of the power meter
BaseUnits
7 (Watts)
RateUnits
0 (None)
UnitModifier
0