HP Insight Management WBEM Providers for HP integrated VMware ESXi Data Sheet

HP Insight Management Power Supply Provider Overview 194
Property Name Property Implementation
SMX_PowerSupply.Caption for the power supply that has
failed.
AlertingManagedElement
WBEM Path of SMX_PowerSupply instance representing the
failed power supply.
AlertingElementFormat
2 (CIMObjectPath)
AlertType
5 (Device Alert)
EventID 3
ProviderName HP Power
RecommendedActions
Check the failed power supply and replace if necessary.
HP_AlertIndication
Summary Power supply failed
EventCategory
16 (System Power)
ProbableCause
89 (Power Supply Failure)
ProbableCauseDescription Power Supply Failed
HP_DeviceIndication: Power Supply Degraded
.
Property Name
Property Implementation
CIM_Indication
PerceivedSeverity
5 (Major)
CIM_AlertIndication
Description
A power supply has failed. PowerSupplyCaption
Where: PowerSupplyCaption is the
SMX_PowerSupply.Caption for the power supply that has
degraded.
AlertingManagedElement
WBEM Path of SMX_PowerSupply instance representing the
degraded power supply.
AlertingElementFormat
2 (CIMObjectPath)
AlertType
5 (Device Alert)
EventID 20
ProviderName HP Power
RecommendedActions
Check the degraded power supply and replace if
necessary.
HP_AlertIndication
Summary Power supply degraded
EventCategory
16 (System Power)
ProbableCause
1 (Other)