HP Insight Management WBEM Providers for HP integrated VMware ESXi Data Sheet

HP Insight Management Power Supply Provider Overview 197
HP_DeviceIndication: Power Supply Redundancy Failed
Important: This indication is not supported on HP Proliant systems since redundancy set failure,
which is failure beyond redundancy lost, will cause system shutdown.
Property Name Property Implementation
CIM_Indication
PerceivedSeverity
5 (Major)
CIM_AlertIndication
Description
Power redundancy has been lost. RedundancySetCaption
Where: RedundancySetCaption represents the
SMX_PowerRedundancySet.Caption for the redundancy set that
failed redundancy.
AlertingManagedElement
WBEM Path of SMX_PowerRedundancySet instance representing
the redundancy set where redundancy failed.
AlertingElementFormat
2 (CIMObjectPath)
AlertType
5 (Device Alert)
EventID 20
ProviderName HP Power
RecommendedActions
Check the power supply configuration and check the
status of the power redundancy. Ensure the system is
being powered adequately. Add or replace power supplies
if necessary.
HP_AlertIndication
Summary Power redundancy set failed
EventCategory
16 (System Power)
ProbableCause
88 (Loss of Redundancy)
ProbableCauseDescription Power Redundancy Set has Failed
HP_DeviceIndication: Power Supply Redundancy Restored
Property Name Property Implementation
CIM_Indication
PerceivedSeverity
2 (Information)
CIM_AlertIndication
Description
Power redundancy for the system has been restored.
RedundancySetCaption
Where: RedundancySetCaption is
SMX_PowerRedundancySet.Caption of the redundancy set the power
redundancy set with restored redundancy.
AlertingManagedElement
WBEM Path of SMX_PowerRedundancySet instance representing the