HP Insight Management WBEM Providers for HP integrated VMware ESXi Data Sheet

HP Insight Management WBEM Profile Registration Provider 213
Table Class: SMX_SASFirmware (CIM_SoftwareIdentity)
Property name
Property implementation
SMX_SASFirmware
1-1-13 SMX_SASPrimordialPool
SMX_SASPrimordialPool represents the total raw storage managed by the array controller
that is assigned to Raid volumes.
Table Class: SMX_SASPrimordialPool (CIM_StoragePool)
Property name
Property implementation
CIM_ManagedElement
ElementName Controller name and location: pool identifier.
For example, HP 8 INT Port SAS/SATA HBA in Slot 3:
Primordial Pool
CIM_ManagedSystemElement
CIM_LogicalElement
CIM_StoragePool
InstanceID Opaque key
PoolID Controller serial number
Primordial TRUE
RemainingManagedSpace 0
TotalManagedSpace Total raw space available to controller. This is calculated
by summing the total space on all raid drives connected to
this controller.
SMX_SASPrimordialPool
1-1-14 SMX_SASPrimordialPoolNoRaid
SMX_SASPrimordialPoolNoRaid represents the total raw storage managed by the array
controller that is not assigned to raid volumes.
Table Class: SMX_SASPrimordialPoolNoRaid (CIM_StoragePool)
Property name
Property implementation
CIM_ManagedElement
ElementName Controller name and location: pool identifier
For example, HP 8 INT Port SAS/SATA HBA in Slot 3:
Primordial Pool (No Raid)
CIM_ManagedSystemElement
CIM_LogicalElement
CIM_StoragePool
InstanceID Opaque key
PoolID Controller serial number + :NORAID