HP Insight Management WBEM Providers for HP integrated VMware ESXi Data Sheet

HP Insight Management WBEM Profile Registration Provider 233
Table HP_DeviceIndication: SAS HBA status OK
Property name
Property implementation
CIM_AlertIndication
Description A SAS/SATA HBA status has changed from non-OK to
OK.
AlertingManagedElement WBEM Path of controller
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 1
EventTime Time of the event or time of the indication if event time
unknown
ProviderName HP SAS
RecommendedActions No action is recommended.
SystemName Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating the
indication
HP_AlertIndication
Summary HBA status OK
EventCategory 11 (I/O Adapter)
ProbableCause 1 (Other)
ProbableCauseDescription HBA Status Changed to OK
ProviderVersion Provider version generating the indication in the format,
<major>.<minor>.<revision>.<build>
NetworkAddresses Contains a list of all the IP addresses (IPv4 and IPv6) of the
computer system generating the indication
OSType
On ESXi, 39(VM)
On Linux, 36 (Linux)
OSVersion The operating system version of the computer system
generating the indication in the format:
<major>.<minor>.<build>
SystemFirmwareVersion Firmware version of the computer system generating the
indication
SystemSerialNumber Serial number of the computer system generating the
indication
SystemProductID Product ID of the computer system generating the
indication
SystemModel Model name of the computer system generating the
indication
SystemGUID Platform GUID of the computer system generating the
indication
ImpactedDomain
3 (Enclosure) for c-Class blade systems
4 (System) for all other systems
When ImpactedDomain is 3 (Enclosure), the properties
indicated with (*) are populated.
BladeBay * HP_BladeCSLocation.LocationInformation[0]