HP Insight Management WBEM Providers for HP integrated VMware ESXi Data Sheet

HP Insight Management WBEM Profile Registration Provider 236
Table HP_DeviceIndication: SAS HBA in Error state
Property name
Property implementation
HWManufacturer Controller Manufacturer string
HWSerialNumber Controller Serial Number
HP_DeviceIndication
DeviceModel Controller Model string
1-2-3 Physical Drive Status OK
Table HP_DeviceIndication: Physical Drive status OK
Property name
Property implementation
CIM_Indication
IndicationIdentifier GUID string generated at the time of indication
PreceivedSeverity 2 (Informational)
IndicationTime Time of indication
CIM_AlertIndication
Description A physical drive status has changed from non-OK to OK.
AlertingManagedElement WBEM Path of disk drive
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 201
EventTime Time of the event or time of the indication if event time
unknown
ProviderName HP SAS
RecommendedActions No action is recommended.
SystemName Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating the
indication
HP_AlertIndication
Summary Physical Drive Status is now OK
EventCategory 6 (Primary Storage)
ProbableCause 1 (Other)
ProbableCauseDescription Physical Drive Status Changed to OK
ProviderVersion Provider version generating the indication in the format,
<major>.<minor>.<revision>.<build>
OSType
On ESXi, 39 (VM)
OnLinux, 36 (Linux)
OSVersion The operating system version of the computer system
generating the indication in the format:
<major>.<minor>.<build>