HP Insight Management WBEM Providers for HP integrated VMware ESXi Data Sheet

HP Insight Management WBEM Profile Registration Provider 238
Table HP_DeviceIndication: Physical Drive status ERROR
Property name
Property
implementation
CIM_Indication
IndicationIdentifier GUID string generated at the time of indication
PreceivedSeverity Severity
For example, 5 (Major)
IndicationTime Time of indication
CIM_AlertIndication
Description A physical drive status has changed to Error.
AlertingManagedElement WBEM Path of disk drive
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 202
EventTime Time of the event or time of the indication if event time
unknown
ProviderName HP SAS
RecommendedActions Check for failed or removed physical drives.
SystemName Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating the
indication
HP_AlertIndication
Summary Physical drive status Error
EventCategory 6 (Primary Storage)
ProbableCause 86 (Disk Failure)
ProbableCauseDescription Physical Drive Status Changed to Error
ProviderVersion Provider version generating the indication in the format,
<major>.<minor>.<revision>.<build>
NetworkAddresses Contains a list of all the IP addresses (IPv4 and IPv6) of the
computer system generating the indication
OSType
On ESXi, 39 (VM)
On Linux, 36 (Linux)
OSVersion The operating system version of the computer system
generating the indication in the following format:
<major>.<minor>.<build>
SystemFirmwareVersion Firmware version of the computer system generating the
indication
SystemSerialNumber Serial number of the computer system generating the
indication
SystemProductID Product ID of the computer system generating the
indication
SystemModel Model name of the computer system generating the
indication
SystemGUID Platform GUID of the computer system generating the
indication