HP Insight Management WBEM Providers for HP integrated VMware ESXi Data Sheet

HP Insight Management WBEM Profile Registration Provider 241
Table HP_DeviceIndication: Physical Drive status REBUILDING
Property name
Property implementation
BladeName * HP_ComputerSystem.Name
EnclosureName * HP_BladeEnclosureCS.Name
RackName * Rack name if one exists
RackUID * Rack Unique Identifier if one exists
SystemVirtualSerialNumber Conditional property containing the virtual system serial
number string when running in a Virtual Connect
environment
SystemVirtualUUID Conditional property containing the virtual system UUID
when running in a Virtual Connect environment
HP_HardwareIndication
HWFirmwareVersion Disk firmware version string
HWLogicalLocation Disk Location string
For example, Bay 3
HWManufacturer Disk Manufacturer string
HWSerialNumber Disk Serial Number
HP_DeviceIndication
DeviceModel Disk Model string
1-2-6 Physical Drive status PREDICTIVE FAILURE
Table HP_DeviceIndication: Drive status PREDICTIVE FAILURE
Property name
Property implementation
CIM_Indication
IndicationIdentifier GUID string generated at the time of indication
PreceivedSeverity 5 (Major)
IndicationTime Time of indication
CIM_AlertIndication
Description A physical drive status has changed to Predictive Failure.
AlertingManagedElement WBEM Path of disk drive
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 204
EventTime Time of the event or time of the indication if event time
unknown
ProviderName HP SAS
RecommendedActions Replace drive immediately to avoid loss of data.
SystemName Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating the
indication