HP Insight Management WBEM Providers for HP integrated VMware ESXi Data Sheet

HP Insight Management WBEM Profile Registration Provider 251
Table HP_DeviceIndication: Enclosure Power Supply status changed to OK (Redundant)
Property name
Property implementation
SystemVirtualUUID Conditional property containing the virtual system UUID
when running in a Virtual Connect environment
HP_HardwareIndication
HWLogicalLocation Enclosure Location string
For example, Port 1I Box 1
HWSerialNumber Enclosure Serial Number
HP_DeviceIndication
DeviceModel Enclosure Model string
1-2-12 Enclosure Power Supply Status changed to
Redundant Degraded
Table HP_DeviceIndication: Enclosure Power Supply status changed to Redundant Degraded
Property name
Property implementation
CIM_Indication
IndicationIdentifier GUID string generated at the time of indication
PerceivedSeverity 3 (Warning)
IndicationTime Time of indication
CIM_AlertIndication
Description A Storage Enclosure Power Supply status has changed to
Degraded Redundancy.
AlertingManagedElement WBEM Path of SMX_SASStorageEnclosureProcessor
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 303
EventTime Time of the event or time of the indication if event time
unknown
ProviderName HP SAS
RecommendedActions Check status of all enclosure power supplies. Ensure that
power supplies have not failed. Add or replace power
supplies as necessary.
SystemName Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating the
indication
HP_AlertIndication
Summary Power supply status Redundant Degraded
EventCategory 17 (Primary Storage Power)
ProbableCause 89 (Power supply failure)
ProbableCauseDescription Redundant Power Supply Degraded