HP Insight Management WBEM Providers for HP integrated VMware ESXi Data Sheet

HP Insight Management WBEM Profile Registration Provider 262
Table HP_DeviceIndication: Enclosure Fan status changed to Failure
Property name
Property implementation
CIM_Indication
IndicationIdentifier GUID string generated at the time of indication
PerceivedSeverity 5 (major)
IndicationTime Time of indication
CIM_AlertIndication
Description A Storage Enclosure Fan Status changed to Failure. An
enclosure has detected a failure in the fan subsystem and
there is insufficient fan capability to ensure normal
operation.
AlertingManagedElement WBEM Path of SMX_SASStorageEnclosureProcessor
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 306
EventTime Time of the event or time of the indication if event time
unknown
ProviderName HP SAS
RecommendedActions Ensure that the system is adequately ventilated. Check for
proper room temperature and internal/external airflow. Add
or repair fans and air baffling if necessary.
SystemName Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating the
indication
HP_AlertIndication
Summary Fan status Error
EventCategory 24 (Primary Storage Cooling)
ProbableCause 94 (Fan failure)
ProbableCauseDescription Fan Failure
ProviderVersion Provider version generating the indication in the format,
<major>.<minor>.<revision>.<build>
NetworkAddresses Contains a list of all the IP addresses (IPv4 and IPv6) of the
computer system generating the indication
OSType
On ESXi, 39(VM)
On Linux, 36 (Linux)
OSVersion The operating system version of the computer system
generating the indication in the format:
<major>.<minor>.<build>
SystemFirmwareVersion Firmware version of the computer system generating the
indication
SystemSerialNumber Serial number of the computer system generating the
indication
SystemProductID Product ID of the computer system generating the
indication