HP Insight Management WBEM Providers for HP integrated VMware ESXi Data Sheet

HP Insight Management SAS HBA Provider 266
Table Class: SMX_SASStorageVolume (CIM_StorageVolume)
Property name
Property implementation
CIM_LogicalDevice
CreationClassName SMX_SASStorageVolume
DeviceID Opaque Key
SystemCreationClassName SMX_SASArraySystem
SystemName SMX_SASArraySystem.Name
CIM_StorageExtent
ConsumableBlocks Total Number of blocks on the volume.
BlockSize Block Size in bytes
DataRedundancy
1 (for RAID 0)
2 (for RAID 1)
DeltaReservation Set to a value of 0
ExtentStatus[0] This will indicate extended status for the volume.
2 (None)
11 (Rebuild – Volume is currently rebuilding data)
IsBasedOnUnderlyingRedundancy False
NoSinglePointOfFailure
True—RAID 1 or above
False—RAID 0
NumberOfBlocks Total Number of blocks on the volume.
PackageRedundancy
0 (RAID 0)
1 (RAID 1)
Primordial
TRUE
FALSE (Always set this value to False)
CIM_Storagevolume
NameFormat 7 (SNVM)
SMX_SASStoragevolume
Deleteable See HP SAS HBA Profile
FaultTolerance See HP SAS HBA Profile
OperationalStatus[0] Volume status
0 (Unknown)
2 (OK)
3 (Degraded) - RAID redundancy lost or rebuilding
data
6 (Error)
OSName Corresponding OS name for this volume
1-2-22 SMX_SASDiskDrive
SMX_SASDiskDrive represents the hard drives connected to SAS HBA controllers.