HP Insight Management WBEM Providers for HP integrated VMware ESXi Data Sheet

HP Insight Management SAS HBA Provider 294
Table HP_DeviceIndication: SAS HBA status OK
Property name
Property implementation
BladeName * HP_ComputerSystem.Name
EnclosureName * HP_BladeEnclosureCS.Name
RackName * Rack name if one exists
RackUID * Rack Unique Identifier if one exists
SystemVirtualSerialNumber Conditional property containing the virtual system serial
number string when running in a Virtual Connect
environment
SystemVirtualUUID Conditional property containing the virtual system UUID
when running in a Virtual Connect environment
HP_HardwareIndication
HWFirmwareVersion Controller firmware version string
HWLogicalLocation Controller Location string
For example, Slot 3
HWManufacturer Controller Manufacturer string
HWSerialNumber Controller Serial Number
HP_DeviceIndication
DeviceModel Controller Model string
1-3-2 SAS HBA in Error state
Table HP_DeviceIndication: SAS HBA in Error state
Property name
Property implementation
CIM_Indication
IndicationIdentifier GUID string generated at the time of indication
PreceivedSeverity Severity
5 (Major)
IndicationTime Time of indication
CIM_AlertIndication
Description A SAS/SATA HBA status has changed to Error.
AlertingManagedElement WBEM Path of controller
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 2
EventTime Time of the event or time of the indication if event time
unknown
ProviderName HP SAS
RecommendedActions Replace the HBA.
SystemName Name of the computer system generating the indication