HP Insight Management WBEM Providers for HP integrated VMware ESXi Data Sheet

HP Insight Management SAS HBA Provider 304
Table HP_DeviceIndication: Logical Drive status OK
Property name
Property implementation
OSType
On ESXi, 39 (VM)
On Linux, 36 (Linux)
OSVersion The operating system version of the computer system
generating the indication in the following format:
<major>.<minor>.<build>
SystemFirmwareVersion Firmware version of the computer system generating the
indication
SystemSerialNumber Serial number of the computer system generating the
indication
SystemProductID Product ID of the computer system generating the
indication
SystemModel Model name of the computer system generating the
indication
SystemGUID Platform GUID of the computer system generating the
indication
ImpactedDomain
3 (Enclosure) for c-Class blade systems
4 (System) for all other systems
When ImpactedDomain is 3 (Enclosure), the properties
indicated with (*) are populated.
BladeBay * HP_BladeCSLocation.LocationInformation[0]
BladeName * HP_ComputerSystem.Name
EnclosureName * HP_BladeEnclosureCS.Name
RackName * Rack name if one exists
RackUID * Rack Unique Identifier if one exists
SystemVirtualSerialNumber Conditional property containing the virtual system serial
number string when running in a Virtual Connect
environment
SystemVirtualUUID Conditional property containing the virtual system UUID
when running in a Virtual Connect environment
1-3-8 Logical Drive status ERROR
Table HP_DeviceIndication: Logical Drive status ERROR
Property
name
Property implementation
CIM_Indication
IndicationIdentifier GUID string generated at the time of indication
PreceivedSeverity 5 (Major)
IndicationTime Time of indication
CIM_AlertIndication
Description A logical drive status has changed to Error.
AlertingManagedElement WBEM Path of Storage Volume
AlertingElementFormat 2 (CIMObjectPath)