HP Insight Management WBEM Providers for HP integrated VMware ESXi Data Sheet

HP Insight Management SAS HBA Provider 306
Table HP_DeviceIndication: Logical Drive status ERROR
Property
name
Property implementation
SystemVirtualSerialNumber Conditional property containing the virtual system serial
number string when running in a Virtual Connect
environment
SystemVirtualUUID Conditional property containing the virtual system UUID
when running in a Virtual Connect environment
1-3-9 Logical Drive status Degraded
Table HP_DeviceIndication: Logical Drive is in a degraded state
Property name
Property implementation
CIM_Indication
IndicationIdentifier GUID string generated at the time of indication
PreceivedSeverity 3 (Warning)
IndicationTime Time of indication
CIM_AlertIndication
Description A logical drive is in a degraded state. Device is still
servicing I/O, but redundancy may be degraded or lost.
AlertingManagedElement WBEM Path of Storage Volume
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 103
EventTime Time of the event or time of the indication if event time
unknown
ProviderName HP SAS
RecommendedActions Check status of physical drives. Degraded status may be
caused by failed or missing physical drives, or a data
recovery operation on one or more physical drives.
SystemName Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating the
indication
HP_AlertIndication
Summary Logical drive degraded state
EventCategory 6 (Primary Storage)
ProbableCause 86 (Disk Failure)
ProbableCauseDescription Logical Drive State Changed to Degraded
ProviderVersion Provider version generating the indication in the format,
<major>.<minor>.<revision>.<build>
NetworkAddresses Contains a list of all the IP addresses (IPv4 and IPv6) of the
computer system generating the indication
OSType
On ESXi, 39 (VM)
On Linux, 36 (Linux)