HP Insight Management WBEM Providers for HP integrated VMware ESXi Data Sheet

HP Insight Management SAS HBA Provider 308
Table HP_DeviceIndication: Enclosure Power Supply status changed to Non Redundant
Property name
Property implementation
AlertType 5 (Device Alert)
EventID 301
EventTime Time of the event or time of the indication if event time
unknown
ProviderName HP SAS
RecommendedActions Check status of all enclosure power supplies. Ensure that
power supplies have not failed. Add or replace power
supplies as necessary.
SystemName Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating the
indication
HP_AlertIndication
Summary Power Supply status Non-Redundant
EventCategory 17 (Primary Storage Power)
ProbableCause 89 (Power Supply Failure)
ProbableCauseDescription Redundant Power Supply Status Changed to Non-
Redundant
ProviderVersion Provider version generating the indication in the format,
<major>.<minor>.<revision>.<build>
NetworkAddresses List of all the IP addresses of the computer system
generating the indication
OSType
On ESXi, 39(VM)
On Linux, 36 (Linux)
OSVersion The operating system version of the computer system
generating the indication in the following format:
<major>.<minor>.<build>
SystemFirmwareVersion Firmware version of the computer system generating the
indication
SystemSerialNumber Serial number of the computer system generating the
indication
SystemProductID Product ID of the computer system generating the
indication
SystemModel Model name of the computer system generating the
indication
SystemGUID Platform GUID of the computer system generating the
indication
VariableNames FailureDescription
VariableTypes 1 (String)
VariableValues Short Description of failure
In some cases, the property VariableValues can have N/A
or “” values.
ImpactedDomain
3 (Enclosure) for c-Class blade systems
4 (System) for all other systems
When ImpactedDomain is 3 (Enclosure), the properties
indicated with (*) are populated.