HP Insight Management WBEM Providers for HP integrated VMware ESXi Data Sheet

HP Insight Management SAS HBA Provider 309
Table HP_DeviceIndication: Enclosure Power Supply status changed to Non Redundant
Property name
Property implementation
BladeBay * HP_BladeCSLocation.LocationInformation[0]
BladeName * HP_ComputerSystem.Name
EnclosureName * HP_BladeEnclosureCS.Name
RackName * Rack name if one exists
RackUID * Rack Unique Identifier if one exists
SystemVirtualSerialNumber Conditional property containing the virtual system serial
number string when running in a Virtual Connect
environment
SystemVirtualUUID Conditional property containing the virtual system UUID
when running in a Virtual Connect environment
HP_HardwareIndication
HWLogicalLocation Enclosure Location string
For example, Port 1I Box 1
HWSerialNumber Enclosure Serial Number
HP_DeviceIndication
DeviceModel Enclosure Model string
1-3-11 Enclosure Power Supply Status changed to OK
(Redundant)
Table HP_DeviceIndication: Enclosure Power Supply status changed to OK (Redundant)
Property name
Property implementation
CIM_Indication
IndicationIdentifier GUID string generated at the time of indication
PerceivedSeverity 2 (Info)
IndicationTime Time of indication
CIM_AlertIndication
Description A Storage Enclosure Power Supply has changed to Fully
Redundant.
AlertingManagedElement WBEM Path of SMX_SASStorageEnclosureProcessor
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 302
EventTime Time of the event or time of the indication if event time
unknown
ProviderName HP SAS
RecommendedActions No action is recommended.
SystemName Name of the computer system generating the indication