HP Insight Management WBEM Providers for HP integrated VMware ESXi Data Sheet

HP Insight Management SAS HBA Provider 316
Table HP_DeviceIndication: Enclosure Temperature sensor status changed to Warning
Property name
Property implementation
VariableValues Short Description of failure
In some cases, the property VariableValues can have N/A
or “” values.
ImpactedDomain
3 (Enclosure) for c-Class blade systems
4 (System) for all other systems
When ImpactedDomain is 3 (Enclosure), the properties
indicated with (*) are populated.
BladeBay * HP_BladeCSLocation.LocationInformation[0]
BladeName * HP_ComputerSystem.Name
EnclosureName * HP_BladeEnclosureCS.Name
RackName * Rack name if one exists
RackUID * Rack Unique Identifier if one exists
SystemVirtualSerialNumber Conditional property containing the virtual system serial
number string when running in a Virtual Connect
environment
SystemVirtualUUID Conditional property containing the virtual system UUID
when running in a Virtual Connect environment
HP_HardwareIndication
HWLogicalLocation Enclosure Location string
For example, Port 1I Box 1
HWSerialNumber Enclosure Serial Number
HP_DeviceIndication
DeviceModel Enclosure Model string
1-3-15 Enclosure Temperature sensor Status Changed to
Critical
Table HP_DeviceIndication: Enclosure Temperature sensor status changed to Critical
Property name
Property implementation
CIM_Indication
IndicationIdentifier GUID string generated at the time of indication
PerceivedSeverity 5 (major)
IndicationTime Time of indication
CIM_AlertIndication
Description A Storage Enclosure Temperature sensor status has
changed to Critical. An enclosure temperature is reaching
the maximum allowed temperature for normal operation. A
shutdown is imminent. Action is required before loss of
data occurs.
AlertingManagedElement WBEM Path of SMX_SASStorageEnclosureProcessor
AlertingElementFormat 2 (CIMObjectPath)