HP Insight Management WBEM Providers for HP integrated VMware ESXi Data Sheet

HP Insight Management WBEM System Temperature Sensor Provider 338
GroupComponent
References SMX_ComputerSystem
PartComponent
References SMX_NumericSensor
Provider Indications
Indications Generated
by the Provider
The following tables describe the SMX WBEM System Temperature Sensor
Provider indications that are implemented for HP ProLiant server platforms
where available.
HP_AlertIndication: Temperature Sensor Threshold Exceeded
Property Name Property Implementation
CIM_Indication
IndicationIdentifier
GUID string generated at the time of indication.
PerceivedSeverity
5 (Major)
IndicationTime
Time of indication.
CIM_AlertIndication
Description
A temperature sensor has detected that the
temperature has exceeded the normal operating
range. <SensorCaption>
Where: <SensorCaption> is the
SMX_NumericSensor.Caption for the sensor that has failed.
AlertingManagedElement
WBEM Path of the SMX_NumericSensor instance representing
the temperature sensor detecting the exceeded threshold.
AlertingElementFormat
2 (CIMObjectPath)
AlertType
5 (Device Alert)
EventID 1
EventTime
Time of the event or time of the indication if event time
unknown
ProviderName HP Temperature
RecommendedActions
Ensure that the system is adequately ventilated.
Check for proper room temperature and
internal/external airflow. Add or repair fans and
air baffling if necessary.
SystemName HP_ComputerSystem.Name
SystemCreationClassName HP_ComputerSystem.CreationClassName
HP_AlertIndication
Summary Temperature threshold exceeded detected
EventCategory
23 (System Cooling)
ProbableCause
51 (Temperature Unacceptable)