HP Insight Management WBEM Providers for HP integrated VMware ESXi Data Sheet

HP Insight Management WBEM Smart Array Provider 345
Unless otherwise noted, all of the property implementation values given are for HP ProLiant and HP Integrity
(cellular and non-cellular) systems. The location related properties and implementation values are
determined based on the server type so they may differ.
SMX_SAArraySystem Class
The SMX_SAArraySystem class implements the HPSA_ArraySystem class and represents the top-level
system. There is one instance per HBA.
The following table lists the properties implemented.
Property Name Property Implementation
CIM_ManagedElement
ElementName
Controller/Storage System name and <physical location>.
Refer to “Physical Location” for more information.
For example:
“Smart Array in Slot=3” for internal
For example:
“Smart Array Embedded Controller=7” for embedded controller
where 7 is the internal identifier for the embedded controller.
CIM_ManagedSystemElement
OperationalStatus[0]
Overall status of the Array System and attached devices.
This is calculated per the algorithm described in the HP Smart Array
Profile.
0 (Unknown)
2 (OK)
3 (Degraded)
6 (Error)
StatusDescriptions[0]
More info for OperationalStatus result. This provides a short
Description to identify who is contributing to non-OK status.
For example:
Controller Failure
Logical Drive Failure
Storage Enclosure Failure
Controller Non-Failure Problem
Physical Drive Non-Failure Problem
Logical Drive Non-Failure Problem
Storage Enclosure Non-Failure Problem
Array is operating properly
Array status is unknown
CIM_LogicalElement
CIM_EnabledLogicalElement
EnabledDefault
2 (Enabled)
EnabledState
5 (Not Applicable)
RequestedState
12 (Not Applicable)