HP Insight Management WBEM Providers for HP integrated VMware ESXi Data Sheet

HP Insight Management WBEM Smart Array Provider 349
Property Name Property Implementation
DeviceID
Opaque Key
SystemCreationClassName SMX_SAArraySystem
SystemName SMX_SAArraySystem.Name
CIM_StorageExtent
ConsumableBlocks
0
BlockSize
Block Size in bytes
DataRedundancy
1 (RAID 0, RAID 5, RAID 6), RAID 50, RAID 60
2 (RAID 1+0)
DeltaReservation
0
ExtentStatus[0]
This will indicate extended status for the volume.
2 (None)
11 (Rebuild – Volume is currently rebuilding data)
IsBasedOnUnderlyingRedundancy False
NoSinglePointOfFailure
True – RAID 1 or above
False – RAID 0
NumberOfBlocks
Total Number of blocks on the volume.
PackageRedundancy
0 (RAID 0)
1 (RAID 1+0, RAID 5)
2 (RAID 6), RAID 50, RAID 60
CIM_Storagevolume
NameFormat
2 (VPD83NAA6)
HPSA_Storagevolume
Accelerator
See HP Smart Array Profile
Deleteable
See HP Smart Array Profile
FaultTolerance
See HP Smart Array Profile
OperationalStatus[0, 1]
Volume status. DMTF defined value will be populated in
index[0] and extended status will be populated in index[1]
per HP Smart Array Profile.
OSName
Corresponding OS name for this volume.
StripeSize
See HP Smart Array Profile
Identify()
See HP Smart Array Profile