HP Insight Management WBEM Providers for HP integrated VMware ESXi Data Sheet

HP Insight Management WBEM Smart Array Provider 352
Property Name Property Implementation
ExtentStatus[0]
This will indicate extended status for the disk drive
Possible values:
2 (None)
11 (Rebuild – disk drive is currently rebuilding data)
NumberOfBlocks
Total number of blocks on disk drive
Primordial
Set to True
TotalPowerOnHours
Total service hours reported disk drive
HPSA_StorageExtent
SMX_SADiskDriveFirmware Class
The SMX_SADiskDriveFirmware class implements the HPSA_DiskDriveFirmware class and represents
the firmware installed on a disk drive. There is one instance per disk drive.
The following table lists the properties implemented.
Property Name Property Implementation
CIM_ManagedElement
ElementName Disk Drive Firmware
CIM_ManagedSystemElement
Name Disk Drive Firmware
CIM_LogicalElement
Caption Disk Drive Firmware
Description Disk Drive Firmware
CIM_SoftwareIdentity
ClassificationDescriptions[0] Disk Drive Firmware
Classifications[0]
10 (Firmware)
InstanceID
Opaque key
Manufacturer
Disk drive vendor string
IdentityInfoType
[0]CIM:SoftwareFamily
[1]HPQ:SoftwareCategory
IdentityInfoValue
[0]HPQ:<TargetType value>
[1]Storage Device
VersionString
Drive firmware as reported from SCSI identify command
HPSA_DiskDriveFirmware