HP Insight Management WBEM Providers for HP integrated VMware ESXi Data Sheet

HP Insight Management WBEM Smart Array Provider 357
Property Name Property Implementation
CIM_ManagedElement
ElementName
Port: <m> Box: <n>
Where: <m> is the port and <n> is the box number.
CIM_ManagedSystemElement
OperationalStatus[0,1, 2, 3 ]
Operational status for enclosure and associated power supplies,
fans and sensors.
The use of OperationalStatus is described in the HP Storage
Enclosure Profile. Index values are populated as follows.
Index[0] – Enclosure status:
0 (Unknown)
2 (OK)
3 (Degraded)
6 (Error)
Index[1] – Fan status (See Profile)
Index[2] – Power Supply status (See Profile)
Index[3] – Temp Sensor Status (See Profile)
Note:
Operational status for Fan, Power and Temp Sensor will be not
detectedfor internal storage enclosure(s) of the local
controller(s)
For example: PCI or Embedded.
CIM_LogicalElement
CIM_EnabledLogicalElement
EnabledDefault
2 (Enabled)
EnabledState
5 (Not Applicable)
RequestedState
12 (Not Applicable)
CIM_System
CreationClassName SMX_SAStorageEnclosureProcessor
Name
Opaque Key
NameFormat Other
CIM_ComputerSystem
Dedicated[0] 2 (Other)
IdentifyingDescriptions[0] Other Vendor Specific Name
OtherDedicatedDescriptions[0]
SDE - indicates Storage Device Enclosure
OtherIdentifyingInfo[0]
Port Number:BoxNumber enclosure is attached to.
For example:
1E:1
HPSA_StorageEnclosureProcessor